11. FUNCTION LOGICS
LOGIC A (Automatic) DIP-SWITCH 1=ON / DIP-SWITCH =OFF
BARRIER
STATUS
INPUTS
OPEN
CLOSE
OPEN / CLOSE
STOP
PHOTOCELLS
DIP-SWITCH
2=ON
DIP-SWITCH
2=OFF
DIP-SWITCH
6=OFF
DIP-SWITCH
6=ON
CLOSED
Opens and
re-closes after
pause time
No effect
Opens and
re-closes after
pause time
Opens and
re-closes after
pause time
No effect
(if active, it
disables all
commands)
No effect
Disables OPEN
commands
OPEN IN
PAUSE
No effect
Closes imme-
diately
Stops operation
and, at next
pulse, closes
Re-closes im-
mediately
Stops operation
Disables
commands at
release resets
pause time
Disables
commands at
release resets
pause time
AT OPENING
No effect
Closes
Stops operation
and, at next
pulse, closes
Reverses mo-
tion on closing Stops operation
No effect
Stops move-
ment and
restarts after
release
AT CLOSING
Reverses on
opening
No effect
Stops operation
and, at next
pulse, opens
Reverses mo-
tion on opening Stops operation
Reverses mo-
tion on opening
Stops move-
ment and
opens at
release
LOGIC M (Manual) DIP-SWITCH 1=OFF / DIP-SWITCH =OFF
BARRIER
STATUS
INPUTS
OPEN
CLOSE
OPEN / CLOSE
STOP
PHOTOCELLS
DIP-SWITCH
2=ON
DIP-SWITCH
2=OFF
DIP-SWITCH
6=OFF
DIP-SWITCH
6=ON
CLOSED
Opens
No effect
Opens
Opens
No effect
(if active, it
disables all
commands)
No effect
Disables OPEN
commands
OPEN
No effect
Closes imme-
diately
Re-closes
immediately
Re-closes
immediately Stops operation
Disables all
commands
Disables com-
mands
AT OPENING
No effect
Closes
Stops operation
and, at next
pulse, closes
Reverses mo-
tion on closing Stops operation
No effect
Stops move-
ment and
restarts after
release
AT CLOSING
Reverses on
opening
No effect
Stops operation
and, at next
pulse, opens
Reverses mo-
tion on opening Stops operation
Reverses mo-
tion on opening
Stops move-
ment and
opens at
release