E604
ENGLISH
Guide for the installer
Pagina 15
To memory store the other channel, repeat all the procedure from point 1.
To add other radio controls, transfer the code of the memory-stored push-button of the radio control to the relevant push-button of
the radio controls to be added, observing the following procedure:
On the memory stored radio control, simultaneously press and hold down push-buttons
P1
and
P2
(see radio control instructions).
The radio control LED begins to flash.
Release both push-buttons.
Put the two radio controls frontally
into contact
.
On the memory stored radio control, press and hold down the push-button relating to the channel you wish to transfer - the radio control
LED lights up on steady beam.
On the radio control to be memory stored, press the required push-button and release it after the radio control has flashed twice.
To finish programming, press twice in close succession, the push-button of the memory stored radio control.
The automated system will perform an opening manoeuvre - make sure that there are no obstacles inside the operating
range.
7.3. Memory storage of LC/RC radio controls
You can memory store up to a maximum of
250 codes
, subdivided between the two channels,
OPEN
and
OPEN/CLOSE
.
Use
LC/RC
remote controls only with receiver module at
4 MHz
.
On the control unit, press the push-button of the channel you wish to memory store,
P2
for the
OPEN
channel or
P
for the
OPEN/
CLOSE
channel.
The relevant LED on the control unit begins to flash - release the push-button.
On the radio control, press the push-button with which you wish to associate the selected channel.
The LED on the control unit lights up on steady beam for about one second, signalling that the radio control was stored in the
memory, then it resumes flashing.
During this stage further radio controls can be stored in the memory.
After about 10 seconds, the control unit automatically exits the learning stage.
To add other radio controls or memory store the second channel, repeat the operations from point 1
7.3.1. r
emote
memory
storAge
oF
lc/rc
rAdio
controls
Other radio controls can be remotely stored only with the
LC/RC
radio controls, i.e. without using the push-buttons of the control unit,, but
using a previously stored radio control.
Get a radio control already memory stored on one of the 2 channels.
Step near to the automated system.
Press and hold down push-buttons
P1
and
P2
(see radio control instructions) simultaneously for about 5 seconds.
Within 5 seconds, press, on the memory stored radio control , the push-button you wish to transfer to the new radio control. In this
way the learning stage on the selected channel is activated on the control unit.
Within 5 seconds, press, on the new radio control, the push-button you wish to associate with the selected channel.
After the new radio control has been stored in the memory, the control unit keeps the learning mode active on the selected channel
for about 5 seconds.
During these 5 seconds, other radio controls can be memory stored on the control unit, as ever associated with the activated
channel.
When 5 seconds have elapsed from memory-storage of the last radio control, the control unit automatically exits the learning
stage.
To check if the radio control was correctly memory stored, wait for 5 seconds after sending the code.
7.4. Deletion of radio codes
To delete
all
the radio controls stored in the memory, go through the following procedure:
Press and hold down one of the two push-buttons
P2
or
P
.
The relevant LED begins to flash.
After five seconds, the LED starts to flash at high speed.
After another five seconds both LEDS,
DL6
and
DL7
light up on steady beam.
Release the push-button.
This operation is irreversible, and all radio controls associated with both the OPEN and the OPEN/CLOSE command will
be deleted.
8. OBSTACLE DETECTION SENSITIVITY
The obstacle detection device enables the control unit to detect any obstacles while the beam is moving. As this is an electronic device, it
stays constant through time and is not subject to variations - this guarantees an automated system with a constant safety level.
By using the
TR1
trimmer, you can increase or reduce the obstacle detection sensitivity. Turn the trimmer
clockwise
to
increase
detection
sensitivity, vice-versa turn it
anti-clockwise
to
reduce
obstacle detection sensitivity.
This device is active both during the beam closing stage and during the beam opening stage.
If it operates during the opening stage
, it stops the operation of the automated system and reverses motion for 1 second. At this point,
a pulse must be sent to the control unit, to resume normal programmed operation.
If it operates during the closing stage
, it reverses operation until the automated system is completely open without disabling any
automatic closing.
If it operates three times in succession
, it blocks the operation of the automated system and locates itself in stop position, disabling
automatic closing, if it was activated. To restore normal operation, you must command the beam to open or close. Behaviour patterns will
differ, according to the command sent:
OPEN
or
OPEN/CLOSE
pulse: In this case, the beam starts an opening manoeuvre at slower speed until the beam is completely open.
When complete opening has been reached, the beam resumes its normal operating cycle, re-activating automatic re-closing, if it had
been enabled.