1.  INTRODUCTION TO THIS IN-

STRUCTION MANUAL

EU DECLARATION OF CONFORMITY

The Manufacturer

Company name:

FAAC S.p.A. Soc. Unipersonale

Address:

Via Calari, 10 - 40069 Zola Predosa BOLOGNA 

- ITALY

hereby declares under its own exclusive liability that the fol-

lowing product:

Description:

electronic equipment

Model:

E145S 

complies with the following applicable EU legislations:

2014/30/EU

2014/35/EU

2011/65/UE

Furthermore, the following harmonised standards have been 

applied:

EN 61000-6-2:2005

EN 61000-6-3:2007+A1:2011

EN 60335-1:2012+A11:2014+A13:2017

Other standards applied:

EN 13849-1:2015 CAT.2 PL “C”

EN 13849-2:2012

EN 60335-2-103:2015

Bologna, 01-08-2020

CEO

A. Marcellan

This manual provides the correct procedures and 

requirements for installing E145S and maintaining it 

in a safe condition.

When drafting the manual, the results of the risk 

assessment conducted by FAAC S.p.A. on the entire 

product life cycle have been taken into account in 

order to implement effective risk reduction measures.

The following stages of the life cycle of the product 

have been considered:

 

-

Delivery/handling

 

-

Assembly and installation

 

-

Set-up and commissioning

 

-

Operation

 

-

Maintenance/troubleshooting

 

-

Disposal at the end of the product’s life cycle

Risks arising from installation and using the product 

have been taken into consideration; these include:

 

-

Risks for the installation/maintenance technician 

(technical personnel)

 

-

Risks for the user of the automation system

 

-

Risks to product integrity (damage)

In Europe, the automation of a gate falls under the Ma-

chinery Directive 2006/42/EC and the corresponding 

harmonised standards.  Anyone automating a gate 

(new or existing) is classified as the Manufacturer of the 

Machine.  They are therefore required by law, among 

other things, to carry out a risk analysis of the machine 

(automatic gate in its entirety) and take protective 

measures to fulfil the essential safety requirements 

specified in Annex I of the Machinery Directive.

FAAC S.p.A. recommends that you always comply 

with the EN 12453 standard and in particular that you 

adopt the safety criteria and devices indicated, without 

exception, including the dead-man function.

This manual also contains general information and 

guidelines, which are purely illustrative and not exhau-

stive, in order to facilitate the activities carried out by 

the Manufacturer of the Machine in all respects with 

regard to carrying out the risk analysis and drafting the 

instructions for use and maintenance of the machine. It 

should be clearly understood that FAAC S.p.A. accepts 

no liability for the reliability and/ or completeness of 

the above instructions.  As such, the manufacturer of 

the machine must carry out all the activities required 

by the Machinery Directive and the corresponding 

harmonised standards on the basis of the actual 

condition of the locations and structures where the 

product E145S will be installed, prior to commissioning 

the machine. These activities include the analysis of all 

the risks associated with the machine and subsequent 

implementation of all safety measures intended to 

fulfil the essential safety requirements.

Summary of Contents for E145S

Page 1: ...E145S...

Page 2: ...Alle vermelde namen en merken zijn eigendom van de respectievelijke fabrikanten Deklantenmogenkopie nmakendieenkelvooreigengebruikbestemdzijn Dez handleiding werd in 2020 gepubliceerd Copyright FAAC...

Page 3: ...7 2 Close the enclosure 20 7 3 Final operations 20 8 ACCESSORIES 21 8 1 Relay photocells 21 8 2 Sensitive edges 22 8 3 Limit switches 22 8 4 BUS 2easy devices 23 Connection 23 BUS 2easy photocells 23...

Page 4: ...chnical personnel Risks for the user of the automation system Risks to product integrity damage InEurope theautomationofagatefallsundertheMa chinery Directive 2006 42 EC and the corresponding harmonis...

Page 5: ...n 1 1 LED off LED on LED flashing LED flashing quickly PERSONAL PROTECTIVE EQUIPMENT Personal protective equipment must be worn to protect against hazards e g crushing cutting shearing etc Obligation...

Page 6: ...eginning of the paragraphs Always comply with the safety recommendations Only the installer and or maintenance technician is are authorised to carry out work on the components of the automation Do not...

Page 7: ...uct s com ponents 3 3 UNAUTHORISED USE Do not use on motors or devices that are intended for purposes other than operating gates Uses other than the intended use are prohibited It is prohibited to ins...

Page 8: ...ruser SimplyConnectrequires an accessory connectivity module to be plugged in which is chosen according to technology used XMB GSM for mobile Bluetooth Low Energy technology XWBL WiFi LAN Bluetooth Lo...

Page 9: ...d in appropriate rigid or flexible conduits either above or below ground Use separate conduits for the power supply and the 12 24 V control devices accessories cables Check buried cable plans to ensur...

Page 10: ...trol devices accessories power supply and output OUT1 J4 Connector 5 pin for FAAC radio decoder boards J5 Connector 3 pin for FAAC XF radio module J6 Removable terminal board for connecting limit swit...

Page 11: ...in two motor systems 11 STOP IN3 Stop command NCcontact connectapush buttonoranothertypeof pulse generator which by opening a contact causes the automation to stop LIftheinputisnotused bridgeitwiththe...

Page 12: ...4 25 26 RADIO RP DEC 2EASY CONNECTIVITY CR2032 USB A EDGE1 OUT1 OP A 24V 24V OP B STOP FSW CL FSW OP OUT2 LOCK1 LOCK2 EDGE2 FCC2 FCA2 FCC1 FCA1 J10 LIf no BUS 2easy devices are used leave the terminal...

Page 13: ...ion of the leaf Use FAAC 12 V 24 V electric locks or generic 24 V 0 5Aelectriclockswithamaximumcurrentof3A RADIO RECEIVER DECODER BOARD J4 ThequickinsertionconnectorJ4isspecificallyfor5 pin FAAC radio...

Page 14: ...motor to terminals M1 For double operator installations connect the motor that opens first to terminals M1 the motor that closes first to terminals M2 The operators MUST be connected to the earth of...

Page 15: ...OP A 24V 24V OP B STOP FSW CL FSW OP OP CL OUT2 LOCK1 LOCK2 EDGE2 FCC2 FCA2 FCC1 FCA1 When the display shows the automation status you can enter basic or advanced programming mode Basic programming 1...

Page 16: ...instepsof10s 00 59 Adjustment step 1 s 1 0 9 5 Adjustment step 10 s 30 Mn NUMBER of MOTORS connected 1 1 motor 2 2 motors 2 Function default F1 MOTOR 1 POWER 01 50 levels 50 maximum power 25 F2 MOTOR...

Page 17: ...ment step 1 s 01 cS CLOSINGTHRUST not displayed if FC 1 Thisfunctionassiststheclosingoftheelectriclock it pushes against the closing stop with maximum forcefor2s DONOTenablethefunctionifthere is not a...

Page 18: ...TIME displayed only if En no and FA FC no or 2 Adds additional operating time at the end of the movement 00 30 Adjustment step 1 s 03 Function default o1 OUT1 Function of output OUT1 00 disabled 01 FA...

Page 19: ...to reopen The triggering of the photocells during movement reverses the gate EP SEMI AUTOMATIC STEP BY STEP This logic only uses the OPEN command OPEN if the automation is closed causes it to open OP...

Page 20: ...EN during closing causes it to reopen Thetriggeringoftheclosingphotocells duringpause reloads the pause time At AUTOMATICTIMER This logic only uses the OPEN command OPEN if the automation is closed ca...

Page 21: ...hingcode from S1 toS4 see SETUP phases If the SETUP procedure doesn t start or stops before it has been completed the board exits from program ming mode and S0 flashes on the display check the ERRORS...

Page 22: ...econditionsofuse For example in particularly windy areas with panelled leaves if the sensitivity of the anti crushing system is too high it can cause frequent unwanted reversals to occur In BASIC PROG...

Page 23: ...ectthephotocellsaccordingtotheir required use FSW CL Photocell active during closing FSW OP Photocell active during opening FSW OP CL Photocell always active LThe action carried out when the photocell...

Page 24: ...k connected in parallel So Sc 2r DO NOT connect photocells to inputs EDGE1 EDGE2 1 Configure the input to which the sensitive edge is connected according to the type used functions So Sc in programmin...

Page 25: ...ransmitter and receiver of a pair of photocells must have the same DIP switch settings There must never be two or more pairs of photocells with the same DIP switch settings If there is more than one p...

Page 26: ...onnect the cables of the encoder to the 2EASY terminal board 2 After turning on power to the board check the LEDs on each encoder with the leaf stationary DL1 lit encoder powered DL2 lit encoder conne...

Page 27: ...0 1 Open A_3 StopNC_1 1 0 1 1 0 Open B_3 1 0 1 1 1 Open A_3 Close 1 1 0 0 0 Open B_4 1 1 0 0 1 Open A_4 Open B_3 1 1 0 1 0 Open B_5 1 1 0 1 1 Open A_4 Open B_4 1 1 1 0 0 1 1 1 0 1 Open A_4 StopNC_2 1...

Page 28: ...XF radio module 1 Insert the XF radio module into the J4 connector beingcarefultoinsertitintherightwayroundand with the mains power switched off J4 2 Turn power on to the board 3 Memorise the radio co...

Page 29: ...ols remotely Use a LC RC radio control that is already use by the automation without having to use the board 1 Takearadiocontrolthatisalreadyinuseandmove close to the board 2 Press buttons P1 and P2 s...

Page 30: ...must be not be any unauthorised persons present for the entire duration of operations carried out remotely SETUP and or modifications to operating parameters LSimply Connect requires E145S firmware v...

Page 31: ...lease the buttons TheprocedureendswhenY appearsonthedisplay If there are errors no appears on the display and the red ERROR LED lights up To display the error code press buttons and simultaneously The...

Page 32: ...ctive Additional LED status or meanings are shown in the section on the accessory to which it refers 10 DIAGNOSTICS 10 1 FIRMWARE VERSION The firmware version is show on the display for 5 seconds each...

Page 33: ...circuit 31 Consecutive ob stacles in open ing The programmed number of con secutive obstacles in opening has been reached Remove the obsta cle If the problem persists repeat the SETUP 32 Movementtime...

Page 34: ...isabled The safety in closing devices have beendisabled viaSimplyConnect 82 Opening sensi tive edge disa bled The opening sensitive edges have beendisabled viaSimplyConnect 83 Closing sensitive edges...

Page 35: ...ment Check that the power supply and connecting cables and the cable glands are intact 12 Check that the connectors and wiring are intact 12 Check that there are no signs of overheating burning etc of...

Page 36: ...tenance is required When the automation reaches the set number of cycles there is a pre flashing of at least 8 s at each movement The user should ask the installer to carry out maintenance 1 In ADVANC...

Page 37: ...FAAC S p A Soc Unipersonale Via Calari 10 40069 Zola Predosa BOLOGNA ITALY Tel 39 051 61724 Fax 39 051 09 57 820 www faac it www faacgroup com E145S 35 532369 Rev A...

Reviews: