10.5 ERROR CODES, ALARMS, INFO
When the ERROR LED is lit, notifications in progress
can be seen on the display (e.g.
Er
07
, or multiple
notifications e.g.
Er
07
16
):
-
when the board is not in the programming menus,
press
++
and
--
at the same time.
1 0
Errors, Alarms, Info
Error
(number on white background)
Alarm
(number on grey background)
Info
(
i
)
00
No warnings
01
Board failure
Perform RESET. If the problem
persists, replace the E145S.
04
Accessories pow-
er supply fault
Check the accessories connection
for short circuits. Check the current
drawn by the connected accessories
and that maximum indicated load is
not exceeded.
Check the accessories protec-
tion fuse (on boards fitted with
one). Perform RESET. If the prob-
lem persists, replace the control
board.
06
Encoder 2 fault Make sure that the encoder is con-
nected properly. If the problem
persists, replace the encoder.
16
Encoder 1 fault Make sure that the encoder is con-
nected properly. If the problem
persists, replace the encoder.
20
FAIL-SAFE test
failed
FAIL-SAFE test of a device
failed. Check the connections,
programming, and that the safety
devices are working correctly.
22
Programming
data corrupted
Programming data NOT valid or
corrupted. Repeat BUS 2easy pro-
gramming and registration.
24
Consecutive ob-
stacles in closing
The programmed number of con-
secutive obstacles in closing has
been reached. Remove the obsta-
cle. If the problem persists, repeat
the SETUP.
25
LOCK1 fault
LOCK1 fault. Check the connec-
tion. Remove the cause of the
short circuit.
26
LOCK2 fault
LOCK2 fault. Check the connec-
tion. Remove the cause of the
short circuit.
31
Consecutive ob-
stacles in open-
ing
The programmed number of con-
secutive obstacles in opening has
been reached. Remove the obsta-
cle. If the problem persists, repeat
the SETUP.
32
Movement time-
out
The movement is in timeout. Check
the manual release. Check the
presence of mechanical stops. If
limit switches are installed, make
sure that they activate correctly. If
the problem persists, replace the
board or motor.
35
BUS 2easy de-
vice fault/con-
flict
Check the addresses of the devices.
36
BUS 2easy short
circuit/overload
Check the connections of the
BUS 2easy devices that are con-
nected and registered.
38
Programming
p a r a m e t e r s
changed
Modified programming, NOT con-
sistent with the SETUP. Restore
the previous settings or carry out
the SETUP procedure.
39
Set-up incorrect/
missing
Perform SETUP.
41
(i)
Date/time miss-
ing
TIMER date/time missing. Replace
the buffer battery BAT1 - CR2032,
then reset the time and date on the
board (from Simply Connect).
42
(i)
Partial open
Automation is in partial open mode.
44
(i)
Emergency input
active
Check the emergency input.
48
Limit switch
fault, leaf 1
Leaf 1 limit switch fault. Check the
connection of the limit switches.
49
Limit switch
fault, leaf 2
Leaf 2 limit switch fault. Check the
connection of the limit switches.
60
Maintenance
request
Ask the installer to carry out sched-
uled maintenance.
61
Obstacle de-
tected Leaf1
An obstacle that prevents the leaf
from moving has been detect-
ed. Remove the obstacle.
62
Obstacle de-
tected Leaf2
An obstacle that prevents the leaf
from moving has been detect-
ed. Remove the obstacle.
63
Intrusion at-
tempt in pro-
gress
An attempt to open the leaf manu-
ally has been detected. Start a
movement.
65
SETUP in pro-
gress
SETUP is in progress. The notifica-
tion remains as long as the phase is
in progress.
67
(i)
Low energy con-
sumption mode
E145S is operating on battery, in
SLEEP mode.
Summary of Contents for E145S