11.  MAINTENANCE

RISKS

PERSONAL PROTECTIVE EQUIPMENT

 

F

Always shut off the power supply before performing 

any maintenance operations.  If the disconnect 

switch is not in view, apply a warning sign stating 

“WARNING - Maintenance in Progress”.  Restore the 

power supply only after finishing any maintenance 

work and restoring the area to normal.

 

!

Maintenance must be performed by the installer or a 

maintenance technician.

Follow all safety recommendations and instructions 

given in this manual.

Mark off the work site and prohibit access/transit. Do 

not leave the work site unattended.

The work area must be kept tidy and clear upon 

completing maintenance.

Before starting work, wait for any hot components 

to cool down.

Do not make any modifications to the original 

components.

FAAC S.p.A. shall bear no liability for damage or 

injury due to components that have been modified 

or otherwise tampered with.

 

i

The warranty shall be forfeited in the event of tamper-

ing with components.

Only use original FAAC spare parts.

11.1  ROUTINE MAINTENANCE

   1 1

 lists the operations that should be performed 

on a regular basis on the E145S board in order to 

keep the automation working reliably and safely; 

these are given purely as a guideline and should not 

be considered exhaustive.  The installer/machine 

manufacturer is responsible for drawing up the main-

tenance plan for the automation, supplementing this 

list or modifying the maintenance operations on the 
basis of the machine characteristics.

   1 1  

Scheduled maintenance

Operation 

   Frequency

Electronic equipment

Check that the power supply and connecting cables and the 

cable glands are intact.

12

Check that the connectors and wiring are intact.

12

Check that there are no signs of overheating, burning etc. of 

electronic components.

12

Check that the earth connections are intact.

12

Check the operation of the circuit breaker and differential 

switch.

12

Control devices

Check that the installed devices and radio controls are in good 

condition and that they operate correctly.

12

Sensitive edges

Check condition, fastening and correct operation.

6

Photocells

Check condition, fastening and correct operation.

6

Check the posts, ensuring that they are intact, correctly 

fastened and free of deformation etc.

6

Flashing light

Check condition, fastening and correct operation.

12

Complete automation system

Check that the automation system operates correctly, 

according to the set parameters, when using the various 

control devices.

12

Check that the gate moves correctly - smooth, regular and 

without abnormal noise.

12

Check that both the opening and closing speed are correct 

and that the stop positions and slow-downs provided for 

are respected.

12

Check that the manual release operates correctly: when the 

release mechanism is activated, it must only be possible to 

move the gate manually.

6

Check that the maximum force required for manual move-

ment of the gate is below 225 N in residential areas and 390 

N in industrial or commercial settings.

6

Check that the sensitive edges operate correctly when an 

obstacle is detected.

6

Check that each pair of photocells is working correctly.

6

Check that there is no optical/light interference between the 

pairs of photocells.

6

Check the force limitation curve (standards EN 12453 and 

EN 12445).  For non-EU countries, of there are no specific local 

regulations, the force must be less than 150 N. 

6

Summary of Contents for E145S

Page 1: ...E145S...

Page 2: ...Alle vermelde namen en merken zijn eigendom van de respectievelijke fabrikanten Deklantenmogenkopie nmakendieenkelvooreigengebruikbestemdzijn Dez handleiding werd in 2020 gepubliceerd Copyright FAAC...

Page 3: ...7 2 Close the enclosure 20 7 3 Final operations 20 8 ACCESSORIES 21 8 1 Relay photocells 21 8 2 Sensitive edges 22 8 3 Limit switches 22 8 4 BUS 2easy devices 23 Connection 23 BUS 2easy photocells 23...

Page 4: ...chnical personnel Risks for the user of the automation system Risks to product integrity damage InEurope theautomationofagatefallsundertheMa chinery Directive 2006 42 EC and the corresponding harmonis...

Page 5: ...n 1 1 LED off LED on LED flashing LED flashing quickly PERSONAL PROTECTIVE EQUIPMENT Personal protective equipment must be worn to protect against hazards e g crushing cutting shearing etc Obligation...

Page 6: ...eginning of the paragraphs Always comply with the safety recommendations Only the installer and or maintenance technician is are authorised to carry out work on the components of the automation Do not...

Page 7: ...uct s com ponents 3 3 UNAUTHORISED USE Do not use on motors or devices that are intended for purposes other than operating gates Uses other than the intended use are prohibited It is prohibited to ins...

Page 8: ...ruser SimplyConnectrequires an accessory connectivity module to be plugged in which is chosen according to technology used XMB GSM for mobile Bluetooth Low Energy technology XWBL WiFi LAN Bluetooth Lo...

Page 9: ...d in appropriate rigid or flexible conduits either above or below ground Use separate conduits for the power supply and the 12 24 V control devices accessories cables Check buried cable plans to ensur...

Page 10: ...trol devices accessories power supply and output OUT1 J4 Connector 5 pin for FAAC radio decoder boards J5 Connector 3 pin for FAAC XF radio module J6 Removable terminal board for connecting limit swit...

Page 11: ...in two motor systems 11 STOP IN3 Stop command NCcontact connectapush buttonoranothertypeof pulse generator which by opening a contact causes the automation to stop LIftheinputisnotused bridgeitwiththe...

Page 12: ...4 25 26 RADIO RP DEC 2EASY CONNECTIVITY CR2032 USB A EDGE1 OUT1 OP A 24V 24V OP B STOP FSW CL FSW OP OUT2 LOCK1 LOCK2 EDGE2 FCC2 FCA2 FCC1 FCA1 J10 LIf no BUS 2easy devices are used leave the terminal...

Page 13: ...ion of the leaf Use FAAC 12 V 24 V electric locks or generic 24 V 0 5Aelectriclockswithamaximumcurrentof3A RADIO RECEIVER DECODER BOARD J4 ThequickinsertionconnectorJ4isspecificallyfor5 pin FAAC radio...

Page 14: ...motor to terminals M1 For double operator installations connect the motor that opens first to terminals M1 the motor that closes first to terminals M2 The operators MUST be connected to the earth of...

Page 15: ...OP A 24V 24V OP B STOP FSW CL FSW OP OP CL OUT2 LOCK1 LOCK2 EDGE2 FCC2 FCA2 FCC1 FCA1 When the display shows the automation status you can enter basic or advanced programming mode Basic programming 1...

Page 16: ...instepsof10s 00 59 Adjustment step 1 s 1 0 9 5 Adjustment step 10 s 30 Mn NUMBER of MOTORS connected 1 1 motor 2 2 motors 2 Function default F1 MOTOR 1 POWER 01 50 levels 50 maximum power 25 F2 MOTOR...

Page 17: ...ment step 1 s 01 cS CLOSINGTHRUST not displayed if FC 1 Thisfunctionassiststheclosingoftheelectriclock it pushes against the closing stop with maximum forcefor2s DONOTenablethefunctionifthere is not a...

Page 18: ...TIME displayed only if En no and FA FC no or 2 Adds additional operating time at the end of the movement 00 30 Adjustment step 1 s 03 Function default o1 OUT1 Function of output OUT1 00 disabled 01 FA...

Page 19: ...to reopen The triggering of the photocells during movement reverses the gate EP SEMI AUTOMATIC STEP BY STEP This logic only uses the OPEN command OPEN if the automation is closed causes it to open OP...

Page 20: ...EN during closing causes it to reopen Thetriggeringoftheclosingphotocells duringpause reloads the pause time At AUTOMATICTIMER This logic only uses the OPEN command OPEN if the automation is closed ca...

Page 21: ...hingcode from S1 toS4 see SETUP phases If the SETUP procedure doesn t start or stops before it has been completed the board exits from program ming mode and S0 flashes on the display check the ERRORS...

Page 22: ...econditionsofuse For example in particularly windy areas with panelled leaves if the sensitivity of the anti crushing system is too high it can cause frequent unwanted reversals to occur In BASIC PROG...

Page 23: ...ectthephotocellsaccordingtotheir required use FSW CL Photocell active during closing FSW OP Photocell active during opening FSW OP CL Photocell always active LThe action carried out when the photocell...

Page 24: ...k connected in parallel So Sc 2r DO NOT connect photocells to inputs EDGE1 EDGE2 1 Configure the input to which the sensitive edge is connected according to the type used functions So Sc in programmin...

Page 25: ...ransmitter and receiver of a pair of photocells must have the same DIP switch settings There must never be two or more pairs of photocells with the same DIP switch settings If there is more than one p...

Page 26: ...onnect the cables of the encoder to the 2EASY terminal board 2 After turning on power to the board check the LEDs on each encoder with the leaf stationary DL1 lit encoder powered DL2 lit encoder conne...

Page 27: ...0 1 Open A_3 StopNC_1 1 0 1 1 0 Open B_3 1 0 1 1 1 Open A_3 Close 1 1 0 0 0 Open B_4 1 1 0 0 1 Open A_4 Open B_3 1 1 0 1 0 Open B_5 1 1 0 1 1 Open A_4 Open B_4 1 1 1 0 0 1 1 1 0 1 Open A_4 StopNC_2 1...

Page 28: ...XF radio module 1 Insert the XF radio module into the J4 connector beingcarefultoinsertitintherightwayroundand with the mains power switched off J4 2 Turn power on to the board 3 Memorise the radio co...

Page 29: ...ols remotely Use a LC RC radio control that is already use by the automation without having to use the board 1 Takearadiocontrolthatisalreadyinuseandmove close to the board 2 Press buttons P1 and P2 s...

Page 30: ...must be not be any unauthorised persons present for the entire duration of operations carried out remotely SETUP and or modifications to operating parameters LSimply Connect requires E145S firmware v...

Page 31: ...lease the buttons TheprocedureendswhenY appearsonthedisplay If there are errors no appears on the display and the red ERROR LED lights up To display the error code press buttons and simultaneously The...

Page 32: ...ctive Additional LED status or meanings are shown in the section on the accessory to which it refers 10 DIAGNOSTICS 10 1 FIRMWARE VERSION The firmware version is show on the display for 5 seconds each...

Page 33: ...circuit 31 Consecutive ob stacles in open ing The programmed number of con secutive obstacles in opening has been reached Remove the obsta cle If the problem persists repeat the SETUP 32 Movementtime...

Page 34: ...isabled The safety in closing devices have beendisabled viaSimplyConnect 82 Opening sensi tive edge disa bled The opening sensitive edges have beendisabled viaSimplyConnect 83 Closing sensitive edges...

Page 35: ...ment Check that the power supply and connecting cables and the cable glands are intact 12 Check that the connectors and wiring are intact 12 Check that there are no signs of overheating burning etc of...

Page 36: ...tenance is required When the automation reaches the set number of cycles there is a pre flashing of at least 8 s at each movement The user should ask the installer to carry out maintenance 1 In ADVANC...

Page 37: ...FAAC S p A Soc Unipersonale Via Calari 10 40069 Zola Predosa BOLOGNA ITALY Tel 39 051 61724 Fax 39 051 09 57 820 www faac it www faacgroup com E145S 35 532369 Rev A...

Reviews: