21
ENGLISH
ENGLISH
J1
J2
J6
J9
J3
J4
J7
MAIN
S/P
VMOT
24V
SP_DOWN
SETUP
SP_UP
DS1
J5
J8
J10
F1
F2
1 2
ON
SECOND MOTOR CONTROL BOARD
SECOND MOTOR CONTROL BOARD
SECOND MOTOR CONTROL BOARD
SECOND MOTOR CONTROL BOARD
SECOND MOTOR CONTROL BOARD
LED
ON
OFF
MAIN
220V~ mains ON
220V~ mains OFF
V MOT
motor powered up
motor powered down
24V
+ 24V ON
+ 24V OFF
PUSH-BUTTON
MEANING
SETUP
inactive
SP-DOWN
inactive
SP-UP
inactive
DS1
MEANING
Dip n°1
to be always positioned to OFF
Dip n°2
posizionare sempre in OFF
FUSE
MEANING
F1
fuse 5x20 T 6.3A/250V (motor
protection)
F2
fuse 5x20 T 1A/250V (24V
protection)
CONNECTOR
MEANING
J1
transformer 40V secondary winding
J2
connector to J1 of 940SDM
J3
connector to J2 of 940SDM
J4
transformer 24V secondary winding
J5
connector to J9 of 940SDM
J6
second motor quick-fit connector
J7
not used
J8
RS232 serial port for PC connection
J9
NOT AUS emergency stop (NC contact)
J10
connector to J3 of batteries board
S/P LED STATUS
MEANING
OFF
normal operating status
ON
no connetting to 940SDM board
INST
INST
INST
INST
INSTALLING SECOND MOTOR
ALLING SECOND MOTOR
ALLING SECOND MOTOR
ALLING SECOND MOTOR
ALLING SECOND MOTOR
BOARD
BOARD
BOARD
BOARD
BOARD
The assembled 940 twin-motor doors are supplied with
pre-wired second-motor board.For Kit doors, fit the
second board using the spacers provided and
positioning them on the 940SDM board to correspond
to the holes as shown in fig. 1 rif.
햲
. Wire up the two units
using the cables provided and following the diagram in
fig. 2.