13
ENGLISH
ENGLISH
The support profile is used when the head profile can be fully
fixed to a metal or masonry bearing structure not showing
significant deformations.
Support profile - securing it to the wall
•Establish the exact location of the head profile considering
the overall dimensions of fig. 2. The head profile must be
secured parallel to the floor.
•To begin with, fit the head profile on a vertical slot at one
end and on a horizontal slot at the other end (using M8
screws and appropriate expansion plugs), and level parallel
to the floor.
Secure at the centre, firmly lifting the head profile to align the
three securing points. Carry out the remaining securing
operations, alternating vertical and horizontal slots (fig. 10).
ATTENTION:
insert the brush (accessory fig.11 ref.
) in the
closing profile before installing.
6.
SECURING THE HEAD PROFILE
Fig. 11
Fig. 10
6.1
Installation of side panels
•Fit the side panels as shown in figures 12.
The side panels are engraved so that they can adapt to
head profiles with or without a free-standing profile.
Fig. 12
7.
INSTALLATION OF BOTTOM SLIDING BLOCKS
The bottom sliding blocks are designed for securing to the wall
(or stationary leaf) or to the floor.
Securing on the wall (or on stationary leaf):
•Assemble the sliding blocks, considering in mind the
dimensions in figs.13 and 15.
•Secure the sliding blocks as shown in fig. 14. ref.
.
Securing on the floor
•Secure the sliding block directly to the floor, as shown in fig.
14. ref.
, using adequate expansion plugs and screws.
3
0
1
2
1
8
14,5
35
30 - 42
Fig. 13
Fig. 14
3
0
1
2
1
8
7
14,5
35
61 -75
Fig. 15
8.
INSTALLATION OF THE LEAVES
•Fit the leaf attachment profile (accessory fig.16 ref.
) on the
top of the leaf, using adequate screws.
•Secure the leaf on the relevant carriages, using the supplied
plates (fig.16 ref.
) and screws (fig. 16 ref.
).
•Position the carriages of the automated system as shown in
figures from3 to 8.
•Tighten the screws of the carriages.