3
ENGLISH
ENGLISH
T
x
R
x
2
3
0
V
~
Fig. 1
Power supply 230V
~
N°
DESCRIPTION
CABLES
External radar
Internal radar
Transmitter
Receiver
SD - Keeper
4x0.25mm²
4x0.25mm²
2x0.25mm²
3x0.25mm²
2x0.5mm² max 50 m
SD - Keeper switch
with lock key
2x0.5mm²
Emerg/Key/Reset
control push-buttons
2x0.5mm²
3x1.5mm²
TAB. 1
TECHNICAL
SPECIFICATIONS
AVAILABLE MODELS
Head profile
Number of leaves
Leaf maximum weight
Width of free transit space Vp
Max thickness of framed leaf
Max absorbed power
Power supply
Protection class
Anti-crushing
activation
Operating ambient temperature
Use frequency
Motor power supply
Head profile length
Opening speed adjustment (load-free)
Closing speed adjustment (load-free)
Partial opening adjustment
Pause time adjustment
Night pause time adjustment
Failsafe on photocells
IP 23 (indoor use)
940SMD1
940SM1
940SM2
940SMD2
Support
Support
12
12
800÷3000
700÷3000
800÷3000
700÷3000
100%
-20°C ÷ +55°C
115V/ 230V~ 50/60Hz
100W
24Vdc
5 ÷ 70 cm/sec.
5 ÷ 70 cm/sec.
10 ÷ 140 cm/sec.
10 ÷ 140 cm/sec.
on opening /closing
0 ÷ 90 sec.
0 ÷ 240 sec.
140
110 + 110
250
180 + 180
10% ÷ 90%
60 mm
1
.
ELECTRICAL EQUIPMENT
can be disabled
200W
See figs. 3 to 8