Battery Back Up System 

When installed, this system will provide battery power in 
the event of a loss of AC power.  How it will function 
depends on two things: 

1.

 

Which logic you are running in (A, EP, or C). 

2.

 

If you choose “Y” or “n” for the AO (Automatic 
Open) function in the programming of the 
885CAT control panel. 

 
If you are running in A or EP mode it will function as 
follows: 

Automatic Open enabled

 (select Y for the AO function 

of the programming) 

When AC power fails, the battery back up instantly 
sends power to the control panel.  The gate opens after a 
short delay and remains open.  Once power returns, one 
of two things will happen, depending on whether you 
have the AC (Automatic Close) function enabled or 
disabled.  If you have chosen “Y” for the AC function, 
the gate will close automatically.  If you have chosen “n” 
for the AC function, the gate will remain open, but be 
ready for a close signal. 
 

Automatic Open disabled

 (select “n” for the AO 

function of the programming) 

When AC power fails, the battery back up instantly 
sends power to the control panel and it is ready for an 
open signal.  If a signal is not received right away, the 
panel “sleeps” until a signal is received.  A signal will 
wake the system up and open the gate.  In this mode 
(Automatic Open disabled), you can continue to open 
and close the gate as long as the batteries are charged.  
Whether you are running in A or EP logic under normal 
power makes no difference.  When running on battery 
power, the gate will operate in EP mode.  The number of 
cycles that you can run with fully charged batteries will 
depend on the length of your gate. 
 
If you are running in C mode it will function as follows: 

Whether you have the Automatic Open (AO) function 
enabled or disabled makes no difference.  When AC 
power fails, the gate will not automatically open.  The 
battery back up instantly sends power to the control 
panel and it is ready for an open signal.  You can open 
the gate one time and then the back up will shut down 
until AC power is restored. 
 
When running on battery power the photobeams will 
function normally in any logic.  The inherent entrapment 
will function, although slightly different than under 
normal AC power.  If the gate is obstructed while 
running under battery power, it will stop and the alarm 
will sound.  Another open signal will silence the alarm 
and the gate will continue in the same direction

Battery Back Up Installation 

WARNING!

 Turn the main power to the operator 

off before performing any of the tasks involved in 
installing the battery back up system.  This 
installation should be performed by qualified 
personnel only.  When you open the battery back up 
system, the box should contain the following: 

 

 

1- DC Motor 

 

1- Battery back up control panel 

 

2- 12-volt batteries 

 

1- Cross brace for operator chassis 

 

1- Battery tray 

 

1- Set of battery wires 

 

1- 6-wire interface cable 

 

1- 8-wire ribbon cable 

 1- 

Drive 

belt 

 

4- M6 x 20mm carriage bolts 

 

8- M6 flat washers 

 

8- M6 self-locking nuts 

 1- 

Pulley 

 

1- M4 x 12mm bolt 

 

1- M4 fender washer 

 1- 

Feather 

key 

 

2- 16mm wire chase nipples 

 4- 

Snap-in 

standoffs 

 

2- M8 x 20mm hex bolts 

 

2- M8 self-locking nuts 

 
The tools needed for installing the battery back up 
system are as follows: 

 

3mm Allen wrench 

 

Small flat blade screwdriver 

 

10 mm Socket 

 

13 mm socket 

 

13 mm open end wrench 

 
To install the battery back up system, follow the steps 
below and refer to figures 10 and 11. 

1.

 

If you haven’t done so already, turn off the main 
power. 

2.

 

Remove the existing drive belt. 

3.

 

Mount the DC motor in the location shown in 
figure 11.  Secure it with 4 each of the 6mm flat 
washers and self-locking nuts.

 

4.

 

Run the DC motor wires through the wire chase 
directly above the DC motor.  If there is not a 
plastic nipple already installed in the hole, insert 
one of the 16mm chase nipples that was provided 
with the system.  Reach in the left side of the 
operator, under the control panel tray to grab the 
wires and feed them up into the control panel area. 

Summary of Contents for 885

Page 1: ...1...

Page 2: ...ay from the road to eliminate the potential of traffic getting backed up This distance is affected by the size of the gate how often it is used and how fast the gate operates 2 The operator you choose...

Page 3: ...quipment 3 If a gate system component malfunctions turn off the main power before making any attempt to repair it 4 Do not attempt to impede the movement of the gate You may injure yourself as a resul...

Page 4: ...ect Accessory Devices 10 Plug in Loop Detectors 10 Plug in Radio Receiver 10 Slave Card 10 Activation Devices 12 Safety Devices 12 Stop Devices 12 Accessory Power 12 LED Indicators 13 Programming 13 T...

Page 5: ...When you receive your 885 Operator inspect the shipping box for physical damage Then inspect the operator once you have removed it from the box Notify the carrier immediately if you note any damage b...

Page 6: ...s of the operator Remove the operator and use a masonry bit to drill holes the appropriate depth for your concrete anchors Use concrete anchors that are at least 3 long Once the holes are drilled and...

Page 7: ...7 Figure 2 The footprint of the 885 Operator top view...

Page 8: ...at this procedure in the closed position by setting the closed limit 6 12 short as well to be sure that the gate does not travel too far once power is applied Figure 3 The 885 Limit Assemblies Manual...

Page 9: ...the assembly to the right 3 Note the position of the solenoid return springs above and below the solenoid pin and remove them for safekeeping 4 Remove the two clip in nuts that were used to mount the...

Page 10: ...ectrical connections Plug in Loop Detectors The 885 CAT provides terminals for plug in Free Exit and Safety loop detectors When plugging the detectors in be sure that the component side of the detecto...

Page 11: ...Terminal F1 1 6A Accessory DL6 Encoder J6 Radio Receiver F2 12 5A Main Power DL7 Close Limit J7 Battery Back Up DL8 Stop J8 Limit Switches Switches Buttons DL9 Safety 1 J9 Transformer Primary SW1 DL10...

Page 12: ...ate must have normally closed N C contacts Connect the normally closed N C to terminal 3 Safety 1 and the common COM to terminal 5 Common Multiple devices should be connected in series The way that th...

Page 13: ...y programming changes Pause time selects the pause time before automatic close from 0 seconds to 4 minutes A logic only Time is adjusted in one second increments from 0 to 60 seconds After 60 seconds...

Page 14: ...tware of the 885 CAT Y Be sure to choose this setting n Do not use Will cause the control panel not to function Slave selects master or slave operator in a master slave configuration Y slave operator...

Page 15: ...it searches for the limit switches Once it is complete the operator will run at full speed Continue to cycle the gate and test all input devices Be sure that all safety devices are functioning proper...

Page 16: ...must be connected to the master unit 4 Program the following function on the master operator Stand Alone AL Y Slave SL N 5 Program the following function on the slave operator Stand Alone AL Y Slave S...

Page 17: ...nel and it is ready for an open signal You can open the gate one time and then the back up will shut down until AC power is restored When running on battery power the photobeams will function normally...

Page 18: ...to the control panel area Leave enough slack for the four connectors to be plugged into the batteries before the batteries have been slid into the tray Do not install the batteries yet 10 Reach in the...

Page 19: ...rming any maintenance or repairs The manufacturer recommends that only qualified personnel check and maintain the equipment Problem When an activation signal is sent the open light DL3 comes on but th...

Page 20: ...e the power switch on the top of the operator is on 3 Check the F1 and F2 fuses on the control panel with an ohm meter or continuity tester 4 Make sure that the transformer is connected properly to th...

Page 21: ...e or accident or has not been operated in accordance with FAAC International Inc s or FAAC S p A s instructions or has been operated under conditions more severe than or otherwise exceeding those set...

Reviews: