Direction
(selects the opening direction)
The display for this function shows an arrow
that should point toward the open position.
Choose the appropriate direction for your installation.
Automatic Open
(with battery backup only)
Use this feature if you have installed the
optional dc motor, batteries, and battery
backup control unit. Choices are:
Y
Gate automatically opens when power fails.
n
When power fails, gate remains closed until
open input is given.
Be sure to choose
n
if you are not using the optional
battery backup.
Automatic Close
This feature is also for use with or without the
optional battery backup. Choices are:
Y
Gate automatically closes when AC power
returns.
n
When AC power returns, the gate remains open
until an input is given.
Be sure to choose
n
if you are not using the optional
battery backup.
Solenoid
(selects the operation of the manual
release solenoid)
Y
Fail-safe mode: Gate can be moved manually
when power fails.
n
Fail-secure mode: In the event of a power
failure, you must use the manual release
mechanism for manual operation of the gate.
The manual release solenoid must be mounted properly
for your selection (see the Manual Release section on
page 8). The 885 Operator comes with the solenoid
mounted for fail-safe mode.
Alone
(This is a new function that is not yet
incorporated in the software of the 885 CAT.)
Y
Be sure to choose this setting.
n
Do not use. Will cause the control panel not to
function.
Slave
(selects master or slave operator in a
master/ slave configuration)
Y
slave
operator
n
master
operator
If you chose
Y
on the previous function (stand-alone), be
sure to choose
n
(master) now.
Fail-safe test
(photo beam operational test)
This is a European safety test that tests the
photobeams before every cycle. In the U.S. it
is typically left disabled.
Y
enabled
n
disabled
Safety 1
(selects the function of the safety 1
input on terminal 3)
OC
Opening: Gate stops when safety device is
triggered and closes when safety device is
cleared.
Closing: Gate stops when safety device is
triggered and opens when safety device is
cleared.
CL
Opening: No effect
Closing: Gate re-opens when safety device is
triggered.
Partial opening
(Open B input at terminal 2)
Selects the distance of the partial opening from
0.5 meters to 5 meters in 0.5 meter increments.
Leaving the setting at 0 disables the partial opening
feature. 1 meter = 39 inches.
Safety 2
(Use this function to enable or disable
the plug-in safety loop detector).
Y
safety 2 (plug-in detector) is used
n
safety 2 (plug-in detector) is not used.
If you are using the plug-in safety loop detector, be sure
to jump terminal 7 to 8 as well.
Safety 2
(device selection)
This is a new function that is not yet
incorporated in the software of the 885 CAT.
Be sure to choose the
L
setting.
F
Do not use. Will cause the control panel not to
function.
L
Be sure to choose this setting.