Fig. 27
5.2.4. T E R M I N A L
BLOCK J5 (high
voltage)
Terminal block for motor
connection.
Connect the wires to the
terminals of J5 as shown
in Fig.26.
B
L A C K
A N D
B
R O W N
W I R E S
=
electric motor supply
phases
B
LUE
WIRE
= electric motor
common
5.2.5. CONNECTOR J6 (high voltage)
Connector for quick connection of the capacitor.
5.2.6. TERMINAL BLOCK J7 (high voltage)
230V~ terminal block for connection of the flashing light (max
60W).
5.2.7. TERMINAL BLOCK J8 (high voltage)
Terminal block for connection of the 230V~ 50Hz power supply
(L=Line N=Neutral)
Connect the earth wire to the operator as shown in Fig.27.
5.2.8.
INDICATOR LEDS
5 LEDs on the board indicate the status of the terminal inputs
(see Table 4 and fig.28):
L
ED
ON
= contact closed
L
ED
OFF
= contact open
TABLE 4
MEANING OF STATUS INDICATOR LED
S
LED
ON
OFF
OPEN
Command active
Command not active
STOP
Command not active
Command active
FSW
Safeties disengaged
Safeties engaged
FCC
Closing limit disengaged
Closing limit engaged
FCA
Opening limit disengaged
Opening limit engaged
Fig. 25
Fig. 24
5.3.
INSTALLING ELECTRIC LOCK
Since the gear motor allows the gate to be moved manually
when the motor is not running, an electric lock must be
installed to ensure that the gate remains locked when closed.
It must be positioned vertically on the upper guide upright (if
the height of the gate permits) to allow it to be released from
both inside and outside (fig.29).
Fig. 28
Closure
Fig. 29
Upper guide
upright
Electric lock
Post
Lock plate