background image

18

ENGLISH

ENGLISH

5.2.

DESCRIPTION

5.2.1. CONNECTOR J1

The connector J1 is used for the quick connection of
MINIDEC,DECODER, RP RECEIVER boards (Figs. 21,22,23).
Accessory boards are to be inserted with their component
sides facing the inside of the 844MPSR electronic control unit.
Always disconnect the power supply before inserting or
removing accessory boards.

Fig. 20

5. 1. 3.

ELECTRICAL CONNECTIONS

Fig. 23

Fig. 22

Fig. 21

844

MPSR

844

MPSR

844

MPSR

5.2.2. TERMINAL BLOCK J2 (low voltage)

1

&

  5  = Common/Negative of accessor y power supply (-)

2 =

OPEN control device (N.O.)

Any control device (pushbutton, detector,..) which,
on closing the contact, relays an open and/or close
impulse to the gate.
To install more than one Open control device, con-
nect the N.O. contacts in parallel.

3 =

STOP control device (N.C.)

Any control device (e.g. pushbutton) w hich, on
opening a contact, stops the movement of the gate.
To install more than one Stop control device, con-
nect the N.C. contacts in series.
If no Stop control devices are to be connected,
place a jumper across the input and the common
terminal (terminal 1 or 5).

4 =

FSW closure safety device (N.C.)

Any control device (photocells, safety edges, mag-
netic loops) with an N.C. contact which interrupts

the movement of the gate when an obstacle is de-
tected within the protected area.
The task of the closure safety device is to safeguard
the area occupied by the gate during the closing
movement.
The inter vention of safety devices during gate clo-
sure causes the direction of gate movement to be
reversed. These devices do not inter vene dur ing
gate opening movements. If a closure safety device
is tripped when the gate is open or during a pause
time, they will prevent gate closure.
To install more than one safety device, connect the
N.C. contacts in series.
If no closure safety devices are to be installed, place
a jumper across this input and the common ter mi-
nal (terminal 1 or 5).

6

&

8 = 24V

~ accessories power supply

The maximum load of the accessories is 500 mA.
To calculate power draw, refer to the instructions for
the individual accessories.
If the jumper LK1 is broken, the 24V~ accessories
power supply is no longer available (Fig.28).

7 =

24Vdc

 accessories power supply positive (+)

The maximum load of the accessories is 500 mA.
To calculate power draw, refer to the instructions for
the individual accessories.

9 =

Electric lock output (12 Vac)

F o r   o p e ra t i o n   o f   t h e   e l e c t r i c   l o ck ,  re fe r   t o   t h e
dipswitch settings. If two electric locks are installed,
they must be connected in series.

5.2.3. CONNECTORS  J3-J4 (limit switch)

J3 = Connection of limit switch for left-hand closure
J4 = Connection of limit switch for right-hand closure

Refer to Figs. 24-25 for quick connection of the inductive limit
switch sensor for the corresponding gate closure direction.

J4

J3

J2

CH-DX

CH-SX

1     2     3     4     5     6     7     8     9

M

1

2

1

2

3

4

5

J5

J6

J8

J7

230V~ 50Hz

(+6%  -10%)

  C

35

µ

F

FAACLAMP
MINILAMP

Elettroserratura
Electric lock
Electroserrure
Elektrochloss
Electrocerradura

844MPSR

L

N

(L)

FINECORSA
LIMIT SWITCH
FIN DE COURSE
ENDSCHALTER
FIN DE CARRERA

1

2

3

4

5

1

2

Altre sicurezze
Other safeties
Autres sécurités
Andere Sicherheiten
Otros disp. seg.

a

b

MINIDEC
SL/DS

PLUS

844MPS

DECODER
SL/SLP/DS

844MPS

844MPS

Summary of Contents for 844 MC-R

Page 1: ...and subsequent amendments 91 368 EEC 93 44 EEC and 93 68 EEC complieswiththeessentialsafetyrequirementsinthefollowingEECDirectives 73 23 EEC and subsequent amendment 93 68 EEC 89 336 EEC and subsequen...

Page 2: ...automation with a contact opening distance of 3 mm or more We recommend the use of a 6A thermal magnetic circuit breaker with multi pole switching 13 Ensure that a residual current device with a trip...

Page 3: ...ercentage of effective working time opening closing withrespecttothetotalcycletime opening closing pause times It is calculated using the following formula Ta Tc F X 100 Ta Tc Tp Ti where Ta opening t...

Page 4: ...st be no pipes or electrical cables in the area to be dug for installing the foundation plinth If the gear motor is located in a vehicle transit area it is advisable to provide protection against acci...

Page 5: ...Remove the breather screw as shown in Fig 13 and keep it in a safe place Fig 11 Fig 12 Fig 9 Fig 8 Fig 10 4 4 FITTING THE RACK 4 4 1 WELD ON STEEL RACK Fig 14 1 Mount the three threaded bushes on the...

Page 6: ...put terminal block Fig 19 4 4 2 SCREW ON STEEL RACK Fig 15 1 Slide the leaf manually to the closed position 2 Rest the first rack element level on the pinion and insert the spacer in the upper part of...

Page 7: ...te movement to be reversed These devices do not intervene during gate opening movements If a closure safety device is tripped when the gate is open or during a pause time they will prevent gate closur...

Page 8: ...4 and fig 28 LED ON contact closed LED OFF contact open TABLE 4 MEANING OF STATUS INDICATOR LEDS LED ON OFF OPEN Command active Command not active STOP Command not active Command active FSW Safeties d...

Page 9: ...hentherespectivelimitswitchisengaged e g it is released before opening only if the closure limit switch is activated Pre flashing It is possible to select 5 seconds pre flashing of the flashing light...

Page 10: ...inductive proximity limit switch Fig 1 ref 3 When the latter detects the passage of a plate fastened to the top of the rack it stops the movement of the gate To position the two travel stop plates co...

Page 11: ...cial applications 10 MAINTENANCE When performing maintenance always check that the anti crushingclutchiscorrectlyadjustedandthatthesafetydevices operate correctly 10 1 TOPPING UP WITH OIL Check the qu...

Page 12: ...of an opening impulse from a remote control or other suitable control device the control unit will start the motor to move the gate to the open position If automatic operation has been selected sendi...