background image

4

Gate Construction

Vehicular gates should be constructed and installed in 
accordance with ASTM F2200: Standard Specification 
for Automated Vehicular Gate Construction. 

For more information, contact ASTM at: 

www.astm.org

Installation

•  If you have any questions or concerns regarding the 

safety of the gate operating system, do not install the 
operator and consult the manufacturer. 

•  The condition of the gate structure itself directly 

affects the reliability and safety of the gate operator.

•  Only qualified personnel should install this equipment. 

Failure to meet this requirement could cause severe 
injury and/or death, for which the manufacturer 
cannot be held responsible.

•  The installer must provide a main power switch that 

meets all applicable safety regulations.

•  It is extremely unsafe to compensate for a damaged 

gate by increasing hydraulic pressure.

•  Install devices such as reversing edges and photo 

beams to provide better protection for personal 
property and pedestrians. Install reversing devices 
that are appropriate to the gate design and 
application.

•  Before applying electrical power, ensure that voltage 

requirements of the equipment correspond to the 
supply voltage. Refer to the label on your gate 
operator system.

Usage

•  Use this equipment only in the capacity for which it 

was designed. Any use other than that stated should 
be considered improper and therefore dangerous.

•  The manufacturer cannot be held responsible 

for damage caused by improper, erroneous or 
unreasonable use. 

•  If a gate system component malfunctions, 

disconnect the main power before attempting to 
repair it.

•  Do not impede the movement of the gate, you 

may injure yourself or damage the gate system as a 
result.

•  This equipment may reach high thermal 

temperatures during normal operation, therefore use 
caution when touching the external housing of the 
gate operator.

•  Use the manual release mechanism according to 

the procedures presented in this manual.

•  Before performing any cleaning or maintenance 

operations, disconnect power to the equipment.

•  All cleaning, maintenance or repair work must be 

performed by qualified personnel.

General Safety Precautions

9.  For gate operators that utilize a contact sensor (edge 

sensor or similar): 

•  Locate one or more contact sensors where the risk 

of entrapment or obstruction exists, such as at the 
leading edge, trailing edge, and post mounted 
both inside and outside of a vehicular horizontal 
slide gate

•  Locate one or more contact sensors at the bottom 

edge of a vehicular vertical lift gate.

•  Locate one or more contact sensors at the bottom 

edge of a vertical barrier (arm).

•  Locate one or more contact sensors at the pinch 

point of a vehicular vertical pivot gate.

•  Locate hard-wired contact sensors and wiring so 

that communication between sensor and gate 
operator is not subjected to mechanical damage.

•  Locate wireless contact sensors, such as those 

that transmit radio frequency (RF) signals, where 
the transmission of signals are not obstructed or 
impeded by building structures, natural land-
scaping or similar hindrances. Wireless contact 
sensors shall function under their intended end-use 
conditions.

•  Use only FAAC MSE MO, CN60 or M60 edge sensors.

Important Installation Instructions (continued)

Summary of Contents for 770 COMPACT

Page 1: ...UL325 UL991 770 FAAC International Inc Headquarter East Coast Operations 3160 Murrell Road Rockledge FL 32955 Tel 800 221 8278 www faacusa com FAAC International Inc West Coast Operations 357 South Ac...

Page 2: ...SPECIFICATIONS 6 1 1 Technical Specifications 6 1 2 Dimensions 6 1 3 Electrical Setup 6 2 INSTALLATION 7 2 1 Preliminary Checks 7 2 2 Installing the foundation box 7 2 3 Setting up the gate 7 2 4 Ins...

Page 3: ...within line of sight of the gate Activation of the reset control shall not cause the operator to start 7 All warning signs and placards must be installed and easily seen within visible proximity of t...

Page 4: ...stem component malfunctions disconnect the main power before attempting to repair it Do not impede the movement of the gate you may injure yourself or damage the gate system as a result This equipment...

Page 5: ...loading docks or other locations not intended to service the general public RESTRICTED ACCESS VEHICULAR GATE OPERATOR CLASS IV A vehicular gate operator system intended for use in guarded industrial l...

Page 6: ...in good condition Positivestopsareprovidedinthefullyopenedandclosed positions There is a minimum clearance between the bottom edge of gate and ground See Fig 6a where S thickness of guide bracket The...

Page 7: ...Inches 2 2 Installing the foundation box 1 Dig a hole for the foundation box as shown in Fig 5 2 Place the foundation box in the hole refer to the dimen sions provided in Figs 6a and 6b The center of...

Page 8: ...quired by repeating the operations described above 5 Install the electronic control unit Refer to the relative instructions 6 Fasten the box cover using the supplied screws Fig 14 Determine the correc...

Page 9: ...out Fig 16 Ref 4 6 Operate the leaf manually Fig 17 At regular intervals check the structure of the gate and make sure that the hinges are in perfect working order Periodically lubricate the pivot an...

Page 10: ...escription 1 770770 770 24V Motor 2 716078 Gear Box 3 727158 Gear Box Cover 4 718075 Secondary Shaft 5 718076 Internal Shaft Group 6 719165 Slow Shaft 7 390451 Seal Kit 8 63000452 Cap 9 63000590 V Rin...

Page 11: ...2 3 4 5 6 6 Part Part Number Description 1 63000422 Release Levers Kit With Locks 2 63003015 Steel Ball 3 7271985 Cover Plug 4 727157 Box Cover 5 390477 Articulated Lever 6 424010 Manual Release Asse...

Page 12: ...rs dipswitches and pushbutton RADIO Connector for the radio receiver BATTERY Connector for the backup battery J24 Jumper to disable battery charging With the jumper present the battery charger is enab...

Page 13: ...closing safety 5 FSW OP N C Contact for opening safety 6 GND 24 Vdc negative 7 GND 24 Vdc negative 8 24 24 Vdc positive 9 OUT 24 Vdc negative for safety TX photocell monitored 10 FCA 1 Open limit swit...

Page 14: ...between the opening leaves and fixed obstacles walls etc against the risk of entrapment Closing Safety Devices Are active only during the gate closing movement and are suitable for protecting the clo...

Page 15: ...ing and closing areas against the risk of impact Typically these photocells work in combination with other monitored photocell pro tecting closing or opening entrapment zones In that case they can t b...

Page 16: ...one closes During the mo vement a command stops the gate AP Automatic step by step OFF ON ON 0 4 min One command opens waits for the pause time and then closes automatically A command during the pause...

Page 17: ...USE TIME ADJUSTMENT 0 4 min Turn clockwise to increase the pause time TR6 CLOSING DELAY OF LEAF 1 OVER LEAF 2 ADJUSTMENT 0 15 sec Turn clockwise to increase the delay TR1 FORCE ADJUSTMENT MOTOR 1 Turn...

Page 18: ...lt OFF reverse when cleared ON SHADOW LOOP CONFIGURATION SW 9 Selects the behavior of the shadow loop function of the XIB accessory OFF The shadow loop input is active only before a closing command ig...

Page 19: ...S450H S800H OFF OFF OFF S418 OFF OFF ON 415 390 770 ON OFF OFF DS 2 LOCK OUTPUT MODE OUTPUT MODE SW 4 Active only for 3 sec after an open impulse from gate closed OFF Active always except 3 sec befor...

Page 20: ...EN B not active LED DL 16 STOP INPUT N C STOP non active STOP active or wiring error LED DL 17 FSW CL INPUT N C Closing safety devices clear Closing safety devices triggered or wiring error LED DL 18...

Page 21: ...LED status If they are correct replace the encoder Verify motor and encoder wire gauge are correct Verify operator is not on manual and hydraulic units don t need to be bled 6 FAIL SAFE FAILED Verify...

Page 22: ...7 32 17 15 32 The E024U board is supplied on a panel that fits in a 16x14 enclosure 6 3 OBSTACLE DETECTION FUNCTION 7 ENCLOSURE 1 Apply resistance to the gate and adjust the Force to make sure that th...

Page 23: ...ollowing guidelines when installing the AC power 1 Check the local wiring codes in all cases and follow all local building codes Wiring and hookup should be performed by a qualified electrician instal...

Page 24: ...rd could be damaged The E024U board keeps the operating firmware in a field pro grammable memory it can be easily upgraded through the on board USB port 10 FIRMWARE UPGRADE The E024U board allows the...

Page 25: ...t release OPEN stops saves CLOSE OPEN recloses leaves immediately 1 recloses leaves immediately no effect OPEN CLOSE disabled no effect no effect CLOSE disabled no effect OPEN CLOSE disabled CLOSING r...

Page 26: ...LOSE disabled recharges pause time CLOSE disabled CLOSING reopens leaves immediately reopens leaves immediately stops operation no effect reverses at opening see DS1 SW8 stops and opens at release OPE...

Page 27: ...disabled no effect OPEN disabled no effect CLOSE disabled no effect OPEN CLOSE disabled LOGIC C CONTINUOS COMMANDS PULSES SYSTEM STATUS OPEN A OPEN B STOP FSW OP FSW CL FSW CL OP CLOSED opens the lea...

Page 28: ...d to J2 7 Refer to Fig A11 for the wiring schematic 8 Turn power back ON 9 Press and release the SW1 button quickly The board will recognize that the XIB board has been removed 10 Re program run time...

Page 29: ...ion Error condition on the BUS DL2 XIB board malfunction or no power J3 CL terminal open loop detector active or not connected J3 CL terminal closed loop detector in idle condition CL OP BUS BUS BUS N...

Page 30: ...ERSE OPEN LED Turn the power on on the E024U board The LED on the inter face board will blink briefly and then will stay ON solid if the BUS connection is working correctly IMPORTANT Briefly press the...

Page 31: ...been subject to misuse negligence or accident or has not been operated in accordance with FAAC International Inc s or FAAC S p A s instructions or has been operated under conditions more severe than o...

Page 32: ...2016 FAAC International Inc All Rights Reserved Published in Sept 2016...