![background image](http://html1.mh-extra.com/html/faac/740-d/740-d_user-manual_3103150021.webp)
18
ENGLISH
Tab.
3/a
LOGIC
”A
”
PULSES
G
A
TE
ST
A
TUS
OPEN-
A
OPEN-B
STOP
OPENING
SAFETY
DEVICES
C
LOSING
SAFETY
DEVICES
OP/CL
OS.
SAFETY
DEVICE
EDGE
SAFETY
DEVICE
CL
OSED
Opens the leaf and closes it
after pause time
/
Opens leaf for the partial opening time and closes
after pause time
/
No effect (OPEN disabled)
No effect
No effect (OPEN disabled)
OPEN
on
PA
USE
Reloads pause time
/
Stops operation
No effect
Reloads pause time
/
(OPEN disabled)
No effect (OPEN disabled)
ON
CL
OSING
Re-opens the leaf immediately
/
No effect (saves OPEN)
see paragraph 5.2.
Stops and, on r
elease,
re
verses on opening
Re
verses on opening for 2”
0
ON
OPENING
No effect
/
see paragraph 5.2.
No effect
Stops and, on r
elease,
continues opening
Re
verses on closing for 2”
0
STOPPED
Closes the leaf
No effect (OPEN disabled)
No effect
No effect (OPEN disabled)
Tab.
3/b
LOGIC
“AP”
PULSES
G
A
TE
ST
A
TUS
OPEN-
A
OPEN-B
STOP
OPENING
SAFETY
DEVICES
C
LOSING
SAFETY
DEVICES
OP/CL
OS.
SAFETY
DEVICE
EDGE
SAFETY
DEVICE
CL
OSED
Opens the leaf and closes it
after pause time
/
Opens leaf for the partial opening time and closes
after pause time
/
No effect (OPEN disabled)
No effect
No effect (OPEN disabled)
OPEN
on
PA
USE
Re-closes the leaf immediately
Stops operation
No effect
Reloads pause time
/
(OPEN disabled)
No effect (OPEN disabled)
ON
CL
OSING
Re-opens the leaf immediately
/
No effect (saves OPEN)
see paragraph 5.2.
Stops and, on r
elease,
re
verses on opening
Re
verses on opening for 2”
0
ON
OPENING
Stops operation
see paragraph 5.2.
No effect
Stops and, on r
elease,
continues opening
Re
verses on closing for 2”
0
STOPPED
Closes the leaf
No effect (OPEN disabled)
No effect
No effect (OPEN disabled)
Tab.
3/c
LOGIC
”S”
PULSES
G
A
TE
ST
A
TUS
OPEN-
A
OPEN-B
STOP
OPENING
SAFETY
DEVICES
C
LOSING
SAFETY
DEVICES
OP/CL
OS.
SAFETY
DEVICE
EDGE
SAFETY
DEVICE
CL
OSED
Opens leaves and closes
them after pause time
Opens leaf for the partial opening time and closes
after pause time
/
No effect (OPEN disabled)
No effect
No effect (OPEN disabled)
OPEN
on
PA
USE
Re-closes the leaf immediately
Stops operation
No effect
Closes after 5” (OPEN disabled)
No effect (OPEN disabled)
ON
CL
OSING
Re-opens the leaf immediately
No effect (saves OPEN)
see paragraph 5.2.
Stops and, on r
elease,
re
verses on opening
Re
verses on opening for 2”
0
ON
OPENING
Re-closes the leaf immediately
see paragraph 5.2.
No effect
Stops and, on r
elease,
continues opening
Re
verses on closing for 2”
0
STOPPED
Closes the leaf
No effect (OPEN disabled)
No effect
No effect (OPEN disabled)