![FAAC 460-P Manual Download Page 7](http://html1.mh-extra.com/html/faac/460-p/460-p_manual_3112576007.webp)
2 0
ENGLISH
ENGLISH
Terminal block J3 (high-tension outputs)
12 and 13- LAMP (230Vac)
Te r m i n a l s fo r c o n n e c t i n g t h e fl a s h i n g l i g h t
(FAAC Lamp, Minilamp)
14,15,16 - COM/OP1/CL1 = MOTOR 1
Connection of Motor 1 (delayed closure)
COM = motor common (blue cable)
OP1/CL1 = motor phases
Motor 1 is activated in single-leaf opening
Use this output for the single-leaf application
17,18,19 - COM/OP2/CL2 = MOTOR 2
Connection of Motor 2 (delayed opening)
COM = motor common (blue cable)
OP2/CL2 = motor phases
Terminal block J4 (high-tension input)
L - 230 Vac power supply (Live)
N - 230 Vac power supply (Neutral)
Connector J5
Connector J5 (9, fig. 1) is used for quick connection of DECODER,
MINIDEC and RP Receiver (Figs. 10, 11, 12, 13).
Connect by inserting the connector on the accessories cards
perpendicularly to the corresponding connector J5 on the
460P.
Turn off the power supply at the electronic control unit before
connecting and disconnecting.
6 and 7 - Accessories power supply Common/Negative (-)
8
- Warning Light (-)
Warning light power supply negative.
The warning light (
24 Vdc 3 W max.
) must be
inserted between this terminal and the positive of
the accessories power supply (terminal 10 or 11).
Do not exceed the stated power.
Table 5: Warning light standard operation
GATE STATE
CLOSED
OPEN ON PAUSE
CLOSING
OPENING
STOPPED
WARNING LIGHT
Off
On
Flashing
On
On
Ü
The FAACTOTUM can be used to program operation of the
warning light output:
1) Warning light steady during closure 6)
Closing state
2) Courtesy timing
7)
Closed state
3) Panic device active
8)
Stop command active
4) Open state
9)
Pause state
5) Opening state
9 - F-TX (-)
If the FAILSAFE is used (programming it with the FAACTOTUM), this
terminal constitutes the power supply negative for the photocell
transmitter.
10 and 11 - Accessories power supply positive (+24 Vdc)
The maximum accessories load is 500 mA. To calculate absorbed
power, refer to table 6.
Table 6 Accessories consumption
TYPE OF ACCESSORY
NOMINAL DRAWN CURRENT
R 31
50 mA
PLUS 433 E
20 mA
MINIDEC SL / DS
6 mA
DECODER SL / DS
20 mA / 55 mA
RP 433 SL / DS
12 mA / 6 mA
DIGICARD
15 mA
METAL DIGIKEY
15 mA
FOTOSWITCH
90 mA
DETECTOR F4 / PS6
50 mA
MINIBEAM
70 mA
WARNING LIGHT
150 mA
Fig. 13
460 P
Fig. 12
MINIDEC
SL/DS
PLUS
460 P
DECODER
SL
460 P
Fig. 11
Fig. 10
460 P
N.B.
Use a dedicated decoder for each accessory type.