1. DESCRIPTION
The 460P is a microprocessor-based programmable electronic control unit for hydraulic operators constructed in SMT technology.
It is supplied in a standard configuration which can be modified using the FAACTOTUM programmer.
1.3 LAYOUT
1.2 PROGRAMMABLE PARAMETERS
Table 4 Parameters that can be programmed with FAACTOTUM
Operating logics:
A-E-S-EP-P-B-C-B/C or customised
Safety operating logics
Warning light operating logics
Programmable warning light output
Available configurable outputs:
Single leaf opening / Complete opening
Stop
Close
Opening/closing safeties
Panic device
Opening/closing safety edge
Leaf 1 and leaf 2 opening/closing limit switch
G a t e c o d e r
Programming for operation with TIMER
Pre-flashing for opening and/or closing
Independent opening/closing times for each motor
Pause times
Opening/closing leaf delay
Failsafe on safeties
Electric lock opening/closing management
Over pushing stroke during opening and/or closing
Inversion stroke during opening and/or closing
Electronic deceleration:
t i m e d
with limit switches
with Gatecoder
Fig. 1
3
4
5
7
8
9
6
1
2
Table 2 Default programming characteristics
Terminal block inputs
Open
Open single leaf
Stop
Closure safeties
Opening safeties
Operating logic
Automatic
Opening/closing time
25 seconds
Pause time
25 seconds
Closing leaf delay time
5 seconds
Opening leaf delay time
2 seconds
Table 3 Accessories for 460P
FAACTOTUM
for card programming
GATECODER
deceleration/anti-crushing safety
Optional modules
MEI (input expansion module)
MEL1 (electric lock management 1)
MEL2 (electric lock management 2)
1.1 TECHNICAL SPECIFICATIONS
Table 1 460P hardware characteristics
Power supply
230 V ~ (+6% -10%) - 50 Hz
Max. absorbed power
35 W
Max. motor load
800 W
Accessories power supply
24 Vdc
Max. accessories load
0.5 A
Warning light power supply
24 Vdc
Max. warning light load
3 W
Temperature range
-20°C +55°C
Fuses
Motors power supply
Accessories power supply
Logic power supply
Mains filter
Integrated in card
Quick connector
For decoding cards/RP Receiver
C o n n e c t o r
For FAACTOTUM and optional modules
Terminal block outputs
Motor 1
Motor 2
Flashing light
Warning light power supply
Accessories power supply
Terminal block
Removable
The 460P electronic control unit can be installed using the
standard configuration and settings the card is supplied with
(characteristics are given in Table 2).
The FAACTOTUM programmer must be used if the default
configuration requires modification. By using FAACTOTUM it is
possible to modify an extremely wide range of parameters to
customise card operation according to the requirements and
characteristics of the automation.
FAACTOTUM also has a diagnostic function (signalling on the
display the state of the gate and inputs in real time and the
voltage levels on the card) and verifies operation of the
automation and the cycle counts performed.
For details on operation and programming of the FAACTOTUM
refer to its instruction manual.
a
a
a
a
a
Low-tension
terminal block J2
is used to connect the
activating devices and the accessories.
b
b
b
b
b
High-tension
terminal block J3
is used to power the motors
and the flashing light.
c
c
c
c
c
High-tension
terminal block J4
is used for line voltage input.
d
d
d
d
d
Fuse F1 5x20 5A/250V rapid
powers motors and transformer
primary coil.
e
e
e
e
e
Fuse F2 5x20 1.6A/250V delayed
powers accessories.
f
f
f
f
f
Fuse F3 5x20 315mA/250V delayed
powers logic
g
g
g
g
g
LED DL1
indicates the card power supply (lights up) and any
variations in the state of each input (goes out momentarily)
h
h
h
h
h
Connector J1
for inserting optional modules and/or cable
for connection to FAACTOTUM.
i
i
i
i
i
Connector J5
for quick connection of DECODER,MINIDEC, RP
receiver.