![FAAC 460-P Manual Download Page 6](http://html1.mh-extra.com/html/faac/460-p/460-p_manual_3112576006.webp)
1 9
ENGLISH
ENGLISH
Examples of application of safety devices and connections
(using the 460P standard configuration)
Ü
FAILSAFE disabled
No safety device connected
J2
IN4 IN5
- -
+ +
FSW
CL
FSW
OP
6
7
10 11
Fig. 4
One pneumatic safety edge connected as closure safety
device and once connected as opening safety device
7
J2
IN4 IN5
- -
+ +
FSW
CL
FSW
OP
6
10 11
Fig. 5
J2
IN4 IN5
- -
+ +
FSW
CL
FSW
OP
One pair of opening photocells connected
TX
RX
7
6
10 11
Fig. 7
J2
IN4 IN5
- -
+ +
FSW
CL
FSW
OP
One pair of closure photocells connected
TX
RX
7
6
10 11
Fig. 6
J2
IN4 IN5
- -
+ +
FSW
CL
FSW
OP
One pair of closure photocells and one pair of opening
photocells connected
RX CL
RX OP
TX CL
TX OP
7
6
10 11
Fig. 8
J2
IN4 IN5
- -
+ +
FSW
CL
FSW
OP
One pair of closure photocells and one pair of
opening/closure photocells connected
RX CL
RX OP/CL
TX CL
TX OP/CL
7
6
10 11
Fig. 9
1
2
3
4
5
1
2
1
2
3
4
5
1
2
1
2
3
4
5
1
2
1
2
1
2
3
4
5
1
2
3
4
5
1
2
1
2
3
4
5
1
2