2. ELECTRICAL CONNECTIONS USING STANDARD CONFIGURATION
Terminal block J2 (low tension)
1 - IN1 = OPEN-A command - complete opening (N.O.)
This means any device (pushbutton, detector,
etc.) which can give an opening/closing pulse
for both gate leaves through the closure of a
contact.
To i n s t a l l m o r e t h a n o n e O P E N - A d e v i c e
connect the N.O. contacts in parallel.
2 - IN2 = OPEN-B command - single leaf opening (N.O.)
This means any device (e.g. pushbutton) which
can give an opening/closing pulse for the gate
leaf driven by motor M1 through the closure of
a contact.
To install more than one OPEN-B device connect
the N.O. contacts in parallel.
3 - IN3 = STOP command (N.C.)
This means any device (e.g. pushbutton) which
stops the movement of the gate by opening a
contact.
To install more than one stop device connect
the N.C. contacts in series.
Ü
If Stop devices are not connected jumper
t h e i n p u t w i t h t h e c o m m o n c o n t a c t
(terminal 6 or 7).
Fig. 2
460P
Note about safety devices
These are all devices (photocells, safety edges, magnetic coils,
etc.) with an N.C. contact which are activated if an obstacle
obstructs the area protected by the safety devices and stop the
movement of the gate leaves (fig. 3).
Ü
If the opening safety devices are activated when the gate
is closed, they prevent the leaves from opening.
If the closing safety devices are activated when the gate
is open, they prevent the leaves from closing.
4 - IN4 = FSW-CL Closing safety device contact (N.C.)
During closure, activation of the safety devices
causes the gate leaves to reverse their direction
of movement. They are not activated during
opening.
Ü
If closure safety devices are not connected,
jumper this input to the common contact
(terminal 6 or 7).
The function of the closure safety devices is
t o s a f e g u a r d t h e a r e a a ff e c t e d b y t h e
movement of the leaves during closure (B,
fig. 3).
5 - IN5 = FSW-OP Opening safety device contact (N.C.)
During opening the safety devices stop the
movement of the gate leaves. When released
they reverse the direction of movement.
Ü
If opening safety devices are not connected,
jumper this input with the common contact
(terminal 6 or 7).
The function of the opening safety devices
is to safeguard the area behind the gate
leaves (A, fig. 3).
It is possible to connect devices which operate simultaneously
as opening and closing safety devices (see example of safety
device connection).
The gate leaves stop if these safety devices are activated during
opening, then carry on opening when they are released.
The leaves stop moving if these safety devices are activated
during closure, then change direction and open when they are
released.
Fig. 3 shows a recommended example of safety device installation.
Opening
photocells
A
A
A
B
B
Closing photocells
Opening/closing photocells
Fig. 3
IN1
1
IN2
2
IN4
4
IN5
5
-
6
-
7
W-L
8
F-TX
9
+
10
+
11
LAMP
12 13
C OP1 CL1
14 15 16
C OP2 CL2
17 18 19
L N
IN3
3
J2
J3
J4
OPEN-A
OPEN-B
STOP
FSW CL
FSW O
P
WAR
N
IN
G
LIGHT
24 Vdc
3 W max
FAAC LAMP
MINILAMP
M1
M2
C1
C2
BLU
BLU
230 Vac
50 Hz
BLUE
BLUE