background image

Page 20 

January,  200 4 

412 O pe rator And  

455 D  Control Panel I nst allatio n M anual   

P

ROGRAMMING

 

 

To program the automated system, the 
“Programming Mode” must be accessed. 

 
Programming is split into two parts:  BASIC and 
ADVANCED. 

 

B

ASIC

 P

ROGRAMMING

 

 

To access BASIC PROGRAMMING, press the 

“F”

 key. 

 

• 

If you press it (and hold it down), the display 
shows the name of the first function. 

 

• 

If you release the key, the display shows the 
value of the function that can be modified with 
keys 

+

 and 

 . 

 

• 

If you press and hold down the 

“F”

 key again 

(and hold it down), the display shows the name 
of the next function, etc. 

 

• 

When you reach the last function, press 

“F” 

to 

exit the program, and the display resumes 

showing the status of the inputs. 

 
The table on the right shows the sequence of 

functions accessible in BASIC PROGRAMMING. 
 

A

DVANCED

 P

ROGRAMMING

 

 

To access ADVANCED PROGRAMMING, press the 

“F” 

key and, as you hold it down, press the 

“+”

 key: 

 

• 

If you release the 

“+”, 

the display indicates the 

name of the first function. 

 

• 

If you release the 

“F” 

key, too, the display 

shows the value of the function that can be 
modified with keys 

“+”

 and   

“—”. 

 

• 

If you press the “F” key (and hold it down), the 
display shows the name of the next function, 

and if you release it, the value that can be 
modified with keys 

“+”

 and 

“—”. 

 

• 

When you reach the last function, press the “F” 
key to exit the program, and the display 
resumes showing the status of the inputs. 

 

The  table on page 21 shows the sequence of 
functions accessible in 

ADVANCED

 

PROGRAMMING.

 

Display Function 

Default 

 

O

PERATING

 L

OGICS

 

A = Automatic (Timer to Close) 
E = Semi Automatic  
S = Security  

EP = (Semi-Automatic) Step by Step 
B = Manned, Pulsed 
C = Manned, constant 

 

 

P

AUSE

 T

IME

 

This is the time between open and 
closing and is adjustable from 0 to 
4 min. This is only true in “A” 

Mode. (see pause time description) 

 

 

F

ORCE

/T

ORQUE

 M

OTOR

 1 

This adjusts the force / torque that 
motor 1 is applying to the gate 
leaf. Setting is 0 to 50.

*

 

 

 

F

ORCE

/T

ORQUE

 M

OTOR

 2 

This adjusts the force / torque that 
motor 2 is applying to the gate 
leaf. Setting is 0 to 50.

*

 

 

 

C

LOSING

 L

EAF

 D

ELAY

 

Delays the closing of operator 
wired into motor one outputs. Ad-
justable from 0 to 4 minutes 

(Same as pause time) 

 

 

M

OTOR

 R

UN

 T

IME

 

This enables where you choose 
from “simple” learning or 
“complete” learning of the motor 

run time.  See page 10 & 11 for 
complete details.  

 

Simple Learning                                 

                                        ~ 1 s. 

                                                       

 

Complete Learning 

 

                                        > 3 s. 

 

 

E

XIT

 P

ROGRAMMING

 

Exit from programming and return 
to display of inputs status.

 

 

BASIC PROGRAMMING 

+

F

+

*

 

With Hydraulic operators the Force/Torque must be set to 

the maximum setting of 50.

 

PROGRAM BUTTONS 

+ - 

LEFT MIDDLE RIGHT 

T

HE

 455 D C

ONTROL

 P

ANEL

 I

NSTALLATION

 I

NSTRUCTIONS

 

Summary of Contents for 412 Compact

Page 1: ...l the Operator 7 Install the 455 D Control Panel 10 Exploded View 412 12 412 Parts List 13 The 455 D Control Panel General Description 14 Installing the 455 D Control Panel 14 Connect the Main Power S...

Page 2: ...affected by the size of the gate how often it is used and how fast the gate operates 2 The operator you choose to install on your gate must be designed for the type and size of your gate and for the...

Page 3: ...power before making any attempt to repair it 4 Do not attempt to impede the movement of the gate You may injure yourself as a result 5 This equipment may reach high temperatures during operation ther...

Page 4: ...aximum leaf swing deg 110 Thrust and traction3 ft lb Nm 0 294 0 400 0 235 0 320 Stroke in cm 11 3 8 29 Rod speed 4 in sec cm sec 3 4 1 9 5 8 1 6 Thermal cut out deg F deg C 284 140 Operator dimensions...

Page 5: ...s marked DX Be sure to install each on the proper gate leaf see Figure 2 2 Protective covers for the worm screw housing of the operator 1 Package of mounting hardware 2 Rear mounting brackets 2 Rear m...

Page 6: ...anism that precisely controls the force transmitted to the gate leaf through the 412 Operator The Manual Release mechanism is a key operated device that disengages or engages the worm screw drive of t...

Page 7: ...e where the operators are mounted The operator attached to the hinge on the left of the gate must be an SX model If the hinge is on the right side the DX model must be installed Installing the operato...

Page 8: ...front mounting bracket with the short pin and one snap ring on the bottom and one snap ring on the top see Figure 9 11 13 16 in 30 cm 4 in 10 cm 5 29 32 in 15 cm Figure 6 The required dimensions of th...

Page 9: ...Gate post or column Steel elbow A B C D F Centerline of gate leaf E Mounting Dimensions 90 deg Swing 110 deg Swing A 5 3 4 in 14 5 cm 4 7 8 in 12 5 cm B 5 3 4 in 14 5 cm 4 7 8 in 12 5 cm WARNING A an...

Page 10: ...OPERATOR COVER Once the operator is attached to the gate leaf you next prepare the cover for installation Caution If you did not correctly establish the orientation of the gate leaf and properly inst...

Page 11: ...d 455 D Control Panel Installation Manual 1 Operator Wire Gauges for Given Voltage 2 Control Panel 220 VAC 115 VAC 3 Photocell A 2 18 AWG A 2 18 AWG 4 Switch B 4 14 AWG B 4 14 AWG 5 Junction box see t...

Page 12: ...Page 12 January 2004 412 Operator And 455 D Control Panel Installation Manual The 412 Compact Operator...

Page 13: ...p Protective Cover SX 1 8 727147 End Cap Protective Cover DX 1 9 N A Nickel Plated Self Tapping Screw 3 5 x 9 5 mm 3 10 2705 Capacitor For 115 v 25 f 1 10 2707 Capacitor For 220 v 8 f 1 11 727216 Prot...

Page 14: ...that the entire gate system meets all applicable electrical codes The installer should refer to the installation manual for a given operator for more information NOTE An installation is U L compliant...

Page 15: ...e to 2 and the red wire to 3 Wire each leg of the capacitor supplied to terminals 2 3 Note If you want to delay the closing of one gate leaf in a two leaf gate design be sure to connect its operator t...

Page 16: ...in power and send an activating signal to the operator The gate leaf or leaves should open If a gate leaf closes then you need to turn off the main power and reverse the connection of the red and blac...

Page 17: ...e motors without a closed circuit between 11 14 The LED Indicators The nine light emitting diodes LEDs on the control panel can be used to check for the proper function of the devices attached to the...

Page 18: ...he delayed leaf closes at the end of the closing time opening and closing respectively are triggered Use the LEDs and the next table to determine if the accessory devices you have installed are operat...

Page 19: ...ev ices 14 9 C NO Rev ersing Photocells f or opening 1 2 1 2 3 4 5 17 13 19 14 17 Additional Reversing Devices TX RX 1 2 1 2 3 4 5 19 17 12 19 17 Additional Reversing Devices TX RX 1 2 19 12 17 15 Add...

Page 20: ...he value that can be modified with keys and When you reach the last function press the F key to exit the program and the display resumes showing the status of the inputs The table on page 21 shows the...

Page 21: ...ou sands from 0 to 99 thousand cy cles The displayed value is up dated as cycles proceed This func tion can be used to check use of the board or to exploit the Assistance Request function EXTRA WORK T...

Page 22: ...ay stops flashing LEARNING OF OPERATING TIMES WARNING During the learning procedure the safety devices are disabled Therefore any and all traffic must be avoided in the path of the gate leaf s NOTE Pr...

Page 23: ...and must be given to start the slow down phase When the gate operator reaches its positive stop the operator will automatically shut off An open command must be given to start closing gate operator 2...

Page 24: ...g Reversing Device s Warning Light Closed Opens both leaves and closes them after pause time Opens single leaf connected to Motor 1 and closes it after pause time No effect No effect No effect Off Ope...

Page 25: ...s in hibited No effect opening is inhibited No effect opening is inhibited Off Opening Stops Stops Stops Stops gate closes when reversing device no longer trig gered No effect On Opened Closes both le...

Page 26: ...directions before the automatic operator is installed An automatic operator should be installed on the inside of the property fence line Do not install the operator on the public side of the property...

Page 27: ...OPENS BUT DOES NOT CLOSE SOLUTION Make sure you have selected the desired operating mode Verify that the reversing devices are working properly FSWOP and FSWCL should be illuminated except when a rev...

Page 28: ...rdance with FAAC International Inc s or FAAC S p A s instructions or has been operated under conditions more severe than or otherwise exceeding those set forth in the specifications for such product s...

Reviews: