![background image](http://html1.mh-extra.com/html/faac/410-mps/410-mps_manual_3099851009.webp)
16
ENGLISH
Table 3/d
LOGICS "EP"
PULSES
GATE STATUS
OPEN-A
No effect (OPEN inhibited)
OPENING/CLOSING SAFETIES
CLOSING SAFETIES
OPENING SAFETIES
STOP
CLOSED
Opens leaves
No effect (OPEN inhibited)
No
effect
OPEN
CLOSING
Stops closing and, when disengaged,
opens
See paragraph 1.2
Stops
Recloses leaf immediately
No effect
No effect (OPEN inhibited)
Inverts the direction
STOPPED
OPENING
Stops
No effect
(if the gate must open, inhibits OPEN)
No effect
(if gate must close, inhibits OPEN)
No effect
Stops opening and, when disengaged,
continues to open
No effect (OPEN inhibited)
No effect (OPEN inhibited)
Stops
Stops opening and, when disengaged,
closes
LOGICS "AD"
PULSES
GATE STATUS
OPEN-A
OPENING/CLOSING SAFETIES
CLOSING SAFETIES
OPENING SAFETIES
STOP
Table 3/e
CLOSED
OPEN on PAUSE
CLOSING
OPENING
If held, it remains in pause (timer function).
No effect (OPEN inhibited)
Stops closing and, when disengaged,
opens
See paragraph 1.2
Stops opening and, when disengaged,
continues to open
No effect
No effect
No effect (OPEN inhibited)
No effect
No effect (OPEN inhibited)
STOPPED
Freezes pause until disengagement (*1) (OPEN inhibited)
No effect
No effect (OPEN inhibited)
No effect (OPEN inhibited)
Closes leaf/leaves
Stops
Reopens leaves immediately
Stops opening and, when disengaged,
closes
Opens leaves and recloses after pause time
It controls the re-counting of the pause time
Intelligent Security & Fire Ltd.