IMPORTANT NOTICE FOR THE INSTALLER

GENERAL SAFETY REGULATIONS

1) WARNING!

 

FAAC strongly recommends to follow these instructions literally for the safety of persons. Improper

installation or misuse of the product will cause very serious damages to persons.

2) Packaging material (plastic, polystyrene etc.) is a potential hazard and must be kept out of reach of children.

3) Read the instructions carefully before installing the product.

4) Keep these instructions for future reference.

5) This product has been designed and manufactured only for the use stated in this manual. Any other use not expressly

set forth will affect the reliability of the product and/or could be source of hazard.

6) FAAC S.p.A. cannot be held responsible for any damage caused by improper use or different from the use for which

the automation system is destined to.

7) Do not use this device in areas subject to explosion: the presence of flammable gas or fumes is a serious hazard.

8) Mechanical constructive elements must comply with UNI8612, CEN pr EN 12604 and CEN pr EN 12605 standards.

Countries outside the EC shall follow the regulations above besides their national normative references in order to offer
the utmost safety.

9) FAAC cannot be held responsible for failure to observe technical standards in the construction of gates and doors,

or for any deformation of the gates which may occur during use.

10) Installation must comply with UNI8612, CEN pr EN 12453 and CEN pr EN 12635.

The degree of safety of the automation must be C+E.

11) Before carrying out any operations, turn off the system’s main switch.

12) An omnipower switch shall be provided for the installation with an opening distance of the contacts of 3 mm or more.

Alternatively, use a 6A thermomagnetic breaker with multi-pole switching.

13) Ensure that there is a differential switch up-line of the electrical system, with a trip threshold of 0.03A.

14) Check that the earthing plant is in perfect condition and connect it to the metallic parts. Also earth the yellow/green

wire of the operator.

15) The automation is fitted with an anti-crush safety system that is a torque control device. In any case, further safety

devices shall be installed.

16) The safety devices (e.g. photocells, safety edges, etc.) protect areas wherethere is a mechanical movement hazard,

e.g. crushing, entrapment and shearing.

17) Each installation must be fitted with at least one flashing light (e.g. FAAC LAMP, MINILAMP etc.) as well as a warning

plate suitably fixed to the gate, besides the safety devices as per point 16. above.

18) FAAC cannot be held responsible regarding safety and correct functioning of the automation in the event that parts

other than FAAC original parts are used.

19) Use only FAAC original spare parts for maintenance operations.

20) Do not carry out any modifications to automation components.

21) The installer must supply all information regarding manual operation of the system in the event of an emergency and

provide the end-user with the leaflet attached to the product.

22) Keep out of persons when the product is in operation.

23) Keep out of reach of children the remote radio controls and any control devices. The automation could be operated

unintentionally.

24) The end-user must avoid any attempt to repair or adjust the automation personally. These operations must be carried

out exclusively by qualified personnel.

25) What is not explicitly stated in these instructions is not permitted.

Intelligent Security & Fire Ltd.

Summary of Contents for 410 MPS

Page 1: ... pour la nature papier recyclé 100 for nature recycled paper 100 per la natura carta riciclata 100 para la naturaleza 100 papel reciclado C ERME T A Z I E N D A C E R TIF I C A T A UNI EN ISO 9001 085 I n t e l l i g e n t S e c u r i t y F i r e L t d ...

Page 2: ... installation with an opening distance of the contacts of 3 mm or more Alternatively use a 6A thermomagnetic breaker with multi pole switching 13 Ensure that there is a differential switch up line of the electrical system with a trip threshold of 0 03A 14 Check that the earthing plant is in perfect condition and connect it to the metallic parts Also earth the yellow green wire of the operator 15 T...

Page 3: ...es section N B The capacitors are provided with the operators Fig 2 Warning the max accessory load is 250 mA To calculate absorption values refer to table 2 Safety devices These are all devices photocells safety edges magnetic coils etc with an N C normally closed contact which activate if an obstacle obstructs the area protected by the a J1 terminal block fig 2 Earth connection N power supply 230...

Page 4: ...tch SW4 settings They do not engage during the opening cycle N B If closing safety devices are not connected jumper inputs OP and FSWTX fig 4 The purpose of the closing safety devices is to safeguard the zone in which the leaves move during the closing cycle B fig 3 If the Fail Safe function is not used see cabling at page 4 for connections of photocells Important for further information on the op...

Page 5: ... 30Vcc OP CL FSW FSWTX Two pair of closure photocells connected Fig 4 A Fig 5 A Fig 6 A Fig 7 A Fig 8 A Fig 9 A Application examples The following are the commonly used connection arrangements disable fail safe No safety device connected One pneumatic edge connected as closing safety device and one connected as opening safety device 1 pair of closing photocells connected 1 pair of opening photocel...

Page 6: ...adjusting trimmer Time is adjustable from 0 to 120 seconds h LEAF DELAY trimmer closing leaf delay adjusting trimmer Leaf delay time is adjustable from 0 to 28 seconds N B 1 If the opening closing time is less than the set delay time the delayed leaf closes at the end of the closing time 2 In one leaf application set the leaf delay time to minimum i Programmingmicroswitches j Fuse F1 5x20 5 A 250 ...

Page 7: ... the TORQUE trimmer fig 1 ref 5 To reduce torque adjust the trimmer anticlockwise To increase torque adjust the trimmer clockwise In any event FAAC advises not to exceed a torque of 15 Kg measured on the outer edge of the leaf Toensureprecisetorqueadjustmentusealineardynamometer When the 410 MPS card is used on hydraulic operators the torque control device must be set to the maximum value by turni...

Page 8: ...ffect OPEN inhibited OPENING No effect OPEN inhibited Stops closing and when disengaged opens See paragraph 1 2 Stops opening and when disengaged continues to open No effect Stops No effect OPEN inhibited Closes leaf leaves No effect OPEN inhibited No effect No effect OPEN inhibited No effect STOPPED CLOSING OPEN Recloses leaves immediately Reopens leaves immediately PULSES OPENING CLOSING SAFETIE...

Page 9: ...ps opening and when disengaged closes LOGICS AD PULSES GATE STATUS OPEN A OPENING CLOSING SAFETIES CLOSING SAFETIES OPENING SAFETIES STOP Table 3 e CLOSED OPEN on PAUSE CLOSING OPENING If held it remains in pause timer function No effect OPEN inhibited Stops closing and when disengaged opens See paragraph 1 2 Stops opening and when disengaged continues to open No effect No effect No effect OPEN in...

Page 10: ...licación todas las modificaciones que considere oportunas para el perfeccionamiento técnico o para cualquier otro tipo de exigencia de carácter constructivo o comercial FAAC S p A Via Benini 1 40069 Zola Predosa BO ITALIA Tel 051 6172411 Tlx 521087 Fax 051 758518 FAAC per la natura La presente istruzione è realizzata al 100 in carta riciclata Non disperdete nell ambiente gli imballaggi dei compone...