background image

13

ENGLISH

STOP

– Common ( - )

N.C. - STOP contact: 

all devices (such as pushbuttons)

which by opening a contact stop gate movement.
To install several safety stop devices, connect the N.C.
contacts in series.

N.B.

 If the STOP devices are not connected, jumper 

STOP

and 

inputs

.

– Common ( - )

A - TWO-LEAF OPENING (N.O.)

: all devices (pushbuttons ,

photocells, detectors, etc.) which assures opening/closing
of both leaves by closing a contact.
To install several control devices, connect the N.O. contacts
in parallel.

FSWTX

+ –  Photocell transmitter power supply (FailSafe)
To use the Fail-Safe function, power supplies to the photocell
transmitters must be connected.

d

J4 quick connector

 for decoder SL/DS - MINIDEC SL/DS - RP

433 SL/DS cards (figs. 10-11-12-13)

e

TORQUE trimmer

: thrust adjusting trimmer (anti-crushing

safety system).

f

PAUSE trimmer

: pause time adjusting trimmer (A/S AD/

logics).
Pause time is adjustable from 0 to 240 seconds.

g

OP/CL trimmer:

 Opening/Closing time adjusting trimmer

Time is adjustable from 0 to 120 seconds.

h

LEAF DELAY trimmer:

 closing leaf delay adjusting trimmer.

Leaf delay time is adjustable from 0 to 28 seconds.

N.B.:
1)

If the opening/closing time is less than the set delay
time, the delayed leaf closes at the end of the closing
time.

2)

In one-leaf application, set the leaf delay time to
minimum

i

Programming microswitches

j

Fuse F1 5x20 5 A/250 V rapid (motor power supply)

k

Fuse F2 5x20 800 mA/250 V delayed (accessories power

supply)

l

Fuse F4 5x20 250 mA/250 V delayed (transformer power
supply)

m

  

Bridge to enable/disable the Fail-Safe (Fig. 14).

n

          

Bridge to enable/disable the wing opening

      delay(Fig. 14).

Table 2 - Current drawn by accessories

MINIDEC
SL/DS

PLUS

433 E

410 MPS

410 MPS

DECODER
SL

Fig. 10

Fig. 11

410 MPS

Fig. 12

Fig. 13

410 MPS

ACCESSORY

CURRENT DRAWN

PLUS 40 SL

30 mA

PLUS 433 E

20 mA

MINIDEC SL / DS

6 mA

DECODER SL / DS

20 mA / 55 mA

RP 433 SL / DS

12 mA / 6 mA

DIGICARD

15 mA

METAL DIGIKEY

15  mA

FOTOSWITCH

90 mA

DETECTOR F4 / PS6

50 mA

PHOTOBEAM

50 mA

N.B.

 Use a dedicated decoder for other accessory types.

Intelligent Security & Fire Ltd.

Summary of Contents for 410 MPS

Page 1: ... pour la nature papier recyclé 100 for nature recycled paper 100 per la natura carta riciclata 100 para la naturaleza 100 papel reciclado C ERME T A Z I E N D A C E R TIF I C A T A UNI EN ISO 9001 085 I n t e l l i g e n t S e c u r i t y F i r e L t d ...

Page 2: ... installation with an opening distance of the contacts of 3 mm or more Alternatively use a 6A thermomagnetic breaker with multi pole switching 13 Ensure that there is a differential switch up line of the electrical system with a trip threshold of 0 03A 14 Check that the earthing plant is in perfect condition and connect it to the metallic parts Also earth the yellow green wire of the operator 15 T...

Page 3: ...es section N B The capacitors are provided with the operators Fig 2 Warning the max accessory load is 250 mA To calculate absorption values refer to table 2 Safety devices These are all devices photocells safety edges magnetic coils etc with an N C normally closed contact which activate if an obstacle obstructs the area protected by the a J1 terminal block fig 2 Earth connection N power supply 230...

Page 4: ...tch SW4 settings They do not engage during the opening cycle N B If closing safety devices are not connected jumper inputs OP and FSWTX fig 4 The purpose of the closing safety devices is to safeguard the zone in which the leaves move during the closing cycle B fig 3 If the Fail Safe function is not used see cabling at page 4 for connections of photocells Important for further information on the op...

Page 5: ... 30Vcc OP CL FSW FSWTX Two pair of closure photocells connected Fig 4 A Fig 5 A Fig 6 A Fig 7 A Fig 8 A Fig 9 A Application examples The following are the commonly used connection arrangements disable fail safe No safety device connected One pneumatic edge connected as closing safety device and one connected as opening safety device 1 pair of closing photocells connected 1 pair of opening photocel...

Page 6: ...adjusting trimmer Time is adjustable from 0 to 120 seconds h LEAF DELAY trimmer closing leaf delay adjusting trimmer Leaf delay time is adjustable from 0 to 28 seconds N B 1 If the opening closing time is less than the set delay time the delayed leaf closes at the end of the closing time 2 In one leaf application set the leaf delay time to minimum i Programmingmicroswitches j Fuse F1 5x20 5 A 250 ...

Page 7: ... the TORQUE trimmer fig 1 ref 5 To reduce torque adjust the trimmer anticlockwise To increase torque adjust the trimmer clockwise In any event FAAC advises not to exceed a torque of 15 Kg measured on the outer edge of the leaf Toensureprecisetorqueadjustmentusealineardynamometer When the 410 MPS card is used on hydraulic operators the torque control device must be set to the maximum value by turni...

Page 8: ...ffect OPEN inhibited OPENING No effect OPEN inhibited Stops closing and when disengaged opens See paragraph 1 2 Stops opening and when disengaged continues to open No effect Stops No effect OPEN inhibited Closes leaf leaves No effect OPEN inhibited No effect No effect OPEN inhibited No effect STOPPED CLOSING OPEN Recloses leaves immediately Reopens leaves immediately PULSES OPENING CLOSING SAFETIE...

Page 9: ...ps opening and when disengaged closes LOGICS AD PULSES GATE STATUS OPEN A OPENING CLOSING SAFETIES CLOSING SAFETIES OPENING SAFETIES STOP Table 3 e CLOSED OPEN on PAUSE CLOSING OPENING If held it remains in pause timer function No effect OPEN inhibited Stops closing and when disengaged opens See paragraph 1 2 Stops opening and when disengaged continues to open No effect No effect No effect OPEN in...

Page 10: ...licación todas las modificaciones que considere oportunas para el perfeccionamiento técnico o para cualquier otro tipo de exigencia de carácter constructivo o comercial FAAC S p A Via Benini 1 40069 Zola Predosa BO ITALIA Tel 051 6172411 Tlx 521087 Fax 051 758518 FAAC per la natura La presente istruzione è realizzata al 100 in carta riciclata Non disperdete nell ambiente gli imballaggi dei compone...

Reviews: