background image

FAAC S.p.A.

Via Benini, 1
40069 Zola Predosa (BO) - ITALIA
Tel.: 051/61724 - Fax: 051/758518
www.faac.it

732870  Rev. A

Contents

EC DECLARATION OF CONFORMITY FOR MACHINES   ....................................................................................

p.  11

WARNINGS FOR THE INSTALLER   .......................................................................................................................

p. 11

1.

DESCRIPTION AND TECHNICAL SPECIFICATIONS   ....................................................................................

p. 12

1.1.

DIMENSIONS   ................................................................................................................................

p. 12

2.

ELECTRIC DEVICES (standard system)   ....................................................................................................

p. 12

3.

INSTALLING THE AUTOMATED SYSTEM   ......................................................................................................

p. 13

3.1.

PRELIMINARY CHECKS   ................................................................................................................

p. 13

3.2.

INSTALLATION DIMENSIONS   ........................................................................................................

p. 13

3.2.1. GENERAL RULES FOR DETERMINING THE INSTALLATION DIMENSIONS   ............................

p. 13

3.3.

INSTALLATION OF THE OPERATORS   .............................................................................................

p. 13

4.

START-UP   ....................................................................................................................................................

p. 15

4.1.

ADJUSTING THE ANTI-CRUSHING SYSTEM   ..................................................................................

p. 15

5.

FINAL OPERATIONS   ...................................................................................................................................

p. 16

6.

AUTOMATED SYSTEM TEST   .........................................................................................................................

p. 16

7.

MANUAL OPERATION   ...............................................................................................................................

p. 16

8.

RESTORING NORMAL OPERATION MODE   ................................................................................................

p. 17

9.

SPECIAL APPLICATIONS FOR SWING LEAF GATES   ...................................................................................

p. 17

9.1.

OPENING TOWARD THE OUTSIDE, WITH OPERATOR INSTALLED INSIDE   .....................................

p. 17

10. MAINTENANCE  ..........................................................................................................................................

p. 17

11. REPAIRS   .....................................................................................................................................................

p. 17

12. TROUBLE SHOOTING   .................................................................................................................................

p. 18

Read this instruction manual to the letter before you begin to install the product.

Symbol

   highlights notes that are important for people’s safety and for the good condition of the automated system.

Symbol

    draws your attention to the notes about the product’s characteristics or operation.

1

2

7

6

6

4

4

4

4

3

7

3

2

4

3

8

8

7

8
8

8

9

Read this instruction manual to the letter before you begin to install the product.
Symbol   

highlights notes that are important for people’s safety and for the good condition of the automated system.

Contents

Summary of Contents for 104200177

Page 1: ...Leading the way Installation Manual 422 Leading the way Swing Gate System...

Page 2: ...OMATED SYSTEM TEST p 16 7 MANUAL OPERATION p 16 8 RESTORING NORMAL OPERATION MODE p 17 9 SPECIAL APPLICATIONS FOR SWING LEAF GATES p 17 9 1 OPENING TOWARD THE OUTSIDE WITH OPERATOR INSTALLED INSIDE p...

Page 3: ...ger areas against mechanical movement Risks such as crushing dragging and shearing 16 Use of at least one indicator light e g FAACLIGHT is recommended for every system as well as a warning sign adequa...

Page 4: ...ys separate the connection cables of the low voltage accessories from the 230 V power cables Use separate sheaths to avoid any type of interference Fig 3 Fig 2 E P Y T R O T A R E P O D R A D N A T S...

Page 5: ...unctionality we recommend you to respect the indicated dimensions For iron pilasters accurately weld the rear attachment ref Fig 6 directly on the pilaster For masonry pilasters select one of the foll...

Page 6: ...two weld spots protecting the rod against any welding waste NB If the gate structure does not permit the attachment to be firmly fastened take action on the structure creating a solid support base 10...

Page 7: ...e bend guard ref Fig 14 14 Re lock the operator and make the electrical connections of the selected electronic control unit following the relevant instructions Fig 11 Fig 12 4 START UP 4 1 ADJUSTING T...

Page 8: ...Finish the installation operations as follows Close the cover of the release device with the key Remove the breather screw Fig 14 ref 6 AUTOMATED SYSTEM TEST When you have finished installing apply t...

Page 9: ...ening direction To reduce torque turn the screws anti clockwise To increase torque turn the screws clockwise Fig 16 Table C Recommended dimensions for standard operators Rod effective stroke maximum d...

Page 10: ...t p a h c w e r c s r e h t a e r b e h t d e v o m e r e v a h u o y t a h t e r u s e k a M r i a y n a e s a e l e r o t r e d r o n i s e l c y c g n i s o l c d n a g n i n e p o e t a g e t e l...

Page 11: ..._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ n a i c i n h c e T r e m o t s u C 9 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _...

Page 12: ...ric lock as they guarantee mechanical locking of the leaf when the motor is not operating The other models without a hydraulic locking always require one or more electric locks to ensure the leaf is m...

Page 13: ...12 QRWH QRWHV QRWH QRWDV DQPHUNXQJ RSPHUNLQJHQ...

Page 14: ...for either technical or commercial reasons at any time and without revising the present publication FAAC UK Limited 6 Hamilton Close Houndmills Estate Basingstoke RG21 6YT Telephone 01256 318100 Fax 0...

Reviews: