background image

4

S  = 0

S  < 0

S  > 0

Lo

y=65mm.

Fig. 4

dimensions in mm

Standard=933

 mm. - pedestrian=

773 mm.

(1) Length of dimension  “a” - 50 mm.
(2) Length of dimension  “b” + 50 mm.

Fig. 5

3.

INSTALLING THE AUTOMATED SYSTEM

3.2.

INSTALLATION DIMENSIONS

3.1.

PRELIMINARY CHECKS

To ensure a correctly operating automated system, the structure
of the existing gate or gate to be built must satisfy the following
requirements:

Max length of leaves according to the dimensions of Table 1.

A strong and rigid leaf structure.

Smooth, uniform leaves movement, without any irregular friction
during the entire travel;

Existing hinges in good condition.

Travel limit mechanical stops must be provided.

We advise you to carry out the metalwork jobs before installing
the automated system.
The condition of the structure directly influences the reliability and
safety of the automated system.

Table A

: Recommended dimensions for standard operators

Table B

: Recommended dimensions for long operators

(*) Rod effective stroke (**) maximum dimension

c

 = The effective rod stroke is shorter than the maximum stroke,

in order to prevent the rod from reaching its stop point
internally, during the opening and closing stages.

(*) Rod effective stroke (**) maximum dimension

3.3.

INSTALLATION OF THE OPERATORS

1)

Fasten the rear attachment on the pilaster, following the
indications in 

Tables A/B

. Modify, if necessary, the length of

the supplied attachment.

Attention

: To avoid compromising good operator

functionality, we recommend you to respect the indicated
dimensions.
• For iron pilasters, accurately weld the rear attachment
(ref.

, Fig. 6) directly on the pilaster.

• For masonry pilasters, select one of the following solutions:

A) appropriately lay a walling-in plate and then

accurately weld the rear attachment.

B) secure, with screws and expansion plugs, the rear

attachment plate (ref. a, Fig.6) to the pilaster and
then accurately weld the rear attachment to the
plate as shown in Fig. 6.

3.2.1.

GENERAL RULES FOR DETERMINING THE
INSTALLATION DIMENSIONS

If the dimensions indicated in table A or B cannot be executed,
the following must be considered in order to determine different
measurements:
-

to obtain 

90° opening of the leaf: a + b = c.

-

to obtain 

over 90° opening of the leaf: a + b < c.

-

lower a and b dimensions will result in higher speeds

. We advise

you to observe the current legal regulations;

-

limit the difference of the a and b dimensions to within 40 mm

:

higher differences will considerably vary speed during the
opening and closing motion;

-

for reasons of operator dimensions, the

 minimum Z dimension

is 50 mm 

(Fig. 4);

-

if the pilaster dimensions or the position of the hinge (dimension

d

) do not make it possible to contain dimension 

a

 to the

required size, a niche must be made in the pilaster as shown
in Fig. 5;

-

dimension 

a

 must always be larger than dimension 

E

.

For installations opening toward the outside, refer to paragraph
9.1.

g

n

i

n

e

p

O

e

l

g

n

a

a

)

m

m

(

b

)

m

m

(

)

*

(

c

)

m

m

(

)

*

*

(

d

)

m

m

(

°

0

9

0

2

1

0

2

1

0

4

2

0

7

°

0

1

1

0

0

1

0

0

1

0

4

2

0

5

g

n

i

n

e

p

O

e

l

g

n

a

a

)

m

m

(

b

)

m

m

(

)

*

(

c

)

m

m

(

)

*

*

(

d

)

m

m

(

°

0

9

0

8

0

8

0

6

1

0

3

pedestrian operators

Summary of Contents for 104200177

Page 1: ...Leading the way Installation Manual 422 Leading the way Swing Gate System...

Page 2: ...OMATED SYSTEM TEST p 16 7 MANUAL OPERATION p 16 8 RESTORING NORMAL OPERATION MODE p 17 9 SPECIAL APPLICATIONS FOR SWING LEAF GATES p 17 9 1 OPENING TOWARD THE OUTSIDE WITH OPERATOR INSTALLED INSIDE p...

Page 3: ...ger areas against mechanical movement Risks such as crushing dragging and shearing 16 Use of at least one indicator light e g FAACLIGHT is recommended for every system as well as a warning sign adequa...

Page 4: ...ys separate the connection cables of the low voltage accessories from the 230 V power cables Use separate sheaths to avoid any type of interference Fig 3 Fig 2 E P Y T R O T A R E P O D R A D N A T S...

Page 5: ...unctionality we recommend you to respect the indicated dimensions For iron pilasters accurately weld the rear attachment ref Fig 6 directly on the pilaster For masonry pilasters select one of the foll...

Page 6: ...two weld spots protecting the rod against any welding waste NB If the gate structure does not permit the attachment to be firmly fastened take action on the structure creating a solid support base 10...

Page 7: ...e bend guard ref Fig 14 14 Re lock the operator and make the electrical connections of the selected electronic control unit following the relevant instructions Fig 11 Fig 12 4 START UP 4 1 ADJUSTING T...

Page 8: ...Finish the installation operations as follows Close the cover of the release device with the key Remove the breather screw Fig 14 ref 6 AUTOMATED SYSTEM TEST When you have finished installing apply t...

Page 9: ...ening direction To reduce torque turn the screws anti clockwise To increase torque turn the screws clockwise Fig 16 Table C Recommended dimensions for standard operators Rod effective stroke maximum d...

Page 10: ...t p a h c w e r c s r e h t a e r b e h t d e v o m e r e v a h u o y t a h t e r u s e k a M r i a y n a e s a e l e r o t r e d r o n i s e l c y c g n i s o l c d n a g n i n e p o e t a g e t e l...

Page 11: ..._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ n a i c i n h c e T r e m o t s u C 9 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _...

Page 12: ...ric lock as they guarantee mechanical locking of the leaf when the motor is not operating The other models without a hydraulic locking always require one or more electric locks to ensure the leaf is m...

Page 13: ...12 QRWH QRWHV QRWH QRWDV DQPHUNXQJ RSPHUNLQJHQ...

Page 14: ...for either technical or commercial reasons at any time and without revising the present publication FAAC UK Limited 6 Hamilton Close Houndmills Estate Basingstoke RG21 6YT Telephone 01256 318100 Fax 0...

Reviews: