Calibration
The new program loader and EZ12 panels have a couple new ways of calibrating screens. The program
loader still has the ability to initiate calibration from the Panel Menu. Just go in the EZPanel Main
Programming Window, to
Panel > Touch Screen Calibration
, and this will prompt the connected panel
to go through the calibration sequence.
We also now have an on screen calibration option in the setup menu. As well as a USB calibration
option.
Setup Menu Calibration
The setup menu (hold left upper corner (40x40) of screen for 5 seconds) has a button that allows for
Touch Screen Calibration. For more Setup Menu information please see the Setup Menu Section.
Note: If nothing is pressed for 15-20 seconds during calibration mode then previous calibration is used
and panel will restart. Therefore if you accidentally enter calibration mode you only need to wait and
panel will exit by itself.
USB Calibration
You can use any file with the extension .cal on a USB to calibrate the panel. For example an empty text
doc which extension is changed to ".cal"(ex: Calibrate_text.cal). Once USB is put in panel the panel will
immediately enter calibration mode (if it does not then you might need to power cycle the unit). After
calibration mode it will restart, please remove the USB during restart otherwise panel will reenter
calibration mode once it finishes powering up.
Note: USB can be disabled. If it so you will need to go to the setup menu and reenable it for this
functionality.