SW HDMI Series • Remote Communication and Control
24
Command
ASCII Command
(Host to Switcher)
Response
(Unit to Switcher) Additional Description
Input Selection
Select input
X!
!
In
X!
•
All
]
Select input
X!
.
X!
= input number:
0
through the highest
number of inputs on the unit (
2
or
4
).
0
deselects (mutes) all inputs
Video Muting
Video mute
X@
B
Vmt
X@
]
Mute the video signal.
View video mute status
B
X@
]
Show video muting status
X@
. For
X@
:
1
= muted,
0
= unmuted
Audio Muting
Audio mute
X@
Z
Amt
X@
]
Mute the audio signal.
View audio mute status
Z
X@
]
Show audio muting status
X@
. For
X@
:
1
= muted,
0
= unmuted
Video Color Bit Depth
Set video color bit depth mode
E
V
X#
BITD
}
Bitd
V
X#
]
Select color bit depth mode
X#
. For
X#
:
View video color bit depth
mode
E
V
BITD
}
X#
]
0
= automatic, based on the EDID of the
connected output (default).
1
= Force truncation to 8-bit.
Signal Status
Request status of all signals
E
LS
}
Sig
X1)
•
X1)
*
X1)
]
or
Sig
X1)
•
X1)
•
X1)
•
X1)
*
X1)
]
Show signal presence or absence for all
inputs and the output. For
X1)
:
0
= no signal detected.
1
= signal detected.
Request HDCP status
E
HDCP
}
Hdcp
X(
•
X(
*
X(
]
or
Hdcp
X(
•
X(
•
X(
•
X(
*
X(
]
Show HDCP status
X(
for all inputs.
For
X(
:
0
= HDCP not authenticated.
1
= HDCP authenticated.
EDID Minder
Assign EDID to inputs
E
A
X$
EDID
}
Edid
A
X$
]
Select an EDID file for all inputs.
X$
= EDID file location number:
1
–
48
= Factory-supplied EDID (see the
EDID table
on page 19).
49
= Automatic mode (default): EDID of
the connected display is detected
and passed to the inputs.
50
–
53
= User-loaded EDID.
Example:
E
A
9
EDID
}
Edid
A
9
]
Select EDID file 9 (
1
440 x 900
@ 60 Hz)
to be stored in memory for the inputs.
View EDID assignment
E
A
EDID
}
X$
]
Show the number (
X$
) of the EDID file
currently assigned to the inputs.
View EDID in hex format
E
R
EDID
}
X%
]
View the current EDID assignment in
hexadecimal (256 bytes).
X%
= current EDID information in hex.
Command and Response Table for SIS Commands
Summary of Contents for SW HDMI Series
Page 6: ...SW HDMI Series Contents vi...