B-3
MPX Plus 866 A Media Presentation Matrix Switcher • DSP SIS Commands
PRELIMINAR
Y
Symbol definitions
]
= CR/LF (carriage return/line feed) (hex 0D 0A)
}
= Carriage return (no line feed, hex 0D)
•
= Space character
|
= Pipe (vertical bar) character
*
= Asterisk character (which is a command character, not a variable)
E
= Escape key (hex 1B) (use
W
instead of
Esc
for Web browsers)
X6)
= Gain control or mic mix-point
See the tables on page B-4 and B-5.
X6!
= Level value; pre-matrix
(
a
)
, post-matrix
(
c
)
, and mic-mix
(
d
)
See the table on page B-6 through B-8.
-35 dB to + 25 dB, in 0.1 dB increments.
N
Pre-matrix and post-matrix, -12 dB to +12 dB only.
X6@
= Mic/line gain level value
See the table on page B-8.
0 dB to +80 dB, in 1.0 dB increments.
X6#
= Mute status
0 = unmute
1 = mute
X6$
= Group master group number
01 – 32 (repeated as
X2)
in chapter 4,”SIS Programming
and Control”)
X6%
= Group fader setting
dB value, in 0.1 dB increments. The valid range depends
on the type of gain block that is assigned to the group
number (
X6$
) specified in the command:
a
= -120 to +120 (-12.dB to +12.0 dB)
b
= 000 to 800 (0.00 dB to 80.0 dB)
c
= -1,000 to +120 (-100.0 dB to +12.0 dB)
d
= -350 to + 250 (-35.0 dB to + 25.0 dB)
e
= -180 to +240 (-18.0 dB to +24.0 dB)
f
= -640 to 000 (-64.0 dB to 0.00 dB)
X6^
= Group fader offset
dB value, in 0.1 dB increments, to raise or lower a group
fader
X6&
= Group fader soft limit
dB value, in 0.1 dB increments. The valid range must be
within the range for the gain block grouped in
X6%
.
X6*
= Group type
6= gain (
a
through
d
)
12 = mute
18 = gain (
e
and
f
)
X6(
= Personal Identification Number (PIN)
Four numeric digits, default = 0000
X7)
= Protected configuration status
0 = no protected configuration saved
1 = protected configuration saved