IPCP 505 • SIS Programming and Control
66
Command/Response T
able for SIS Commands (continued)
Command
ASCII (T
elnet)
(host to IPCP)
URL Encoded (web)
(host to IPCP)
Response
(IPCP to host)
Additional Description
Relay port use
Pulse r
elay
X!
*3*
X6#
O
X!
%2A
3
%2A
X6#
O
Cpn
X!
•
Rly
X%
]
Tur
n r
elay of
f (open)
X!
*0O
X!
%2A
0O
Cpn
X!
•
Rly
0
]
Tur
n r
elay on (close)
X!
*1O
X!
%2A
1O
Cpn
X!
•
Rly
1
]
Toggle r
elay
X!
*2O
X!
%2A
2O
Cpn
X!
•
Rly
X%
]
V
iew r
elay state
X!
O
X!
O
X%
]
KEY
:
X!
=
Relay port number:
01-08
= Relay port 1-8.
X%
=
On/of
f status:
0
= of
f,
1
= on.
X6#
=
Pulse time in 20 ms incr
ements.
If this parameter is missing or =
0
, then pulse length = default =
25
= 500
ms.
1
= 20
ms (minimum pulse time) to 65535 = 1310700
ms (maximum pulse time)
Switched 12 VDC power output port use
Set a switched power port on or
off
E
P
X!
*
X%
DCPP
}
WP
X!
%2A
X%
DCPP
|
DcppP
X!
*
X%]
Example:
E
P1*0
DCPP
}
WP1
%2A
0
DCPP
|
DcppP1*0
]
Example: T
ur
n 12 VDC output port 1 of
f (no
power output).
V
iew switched power port on/of
f
status
E
P
X!
DCPP
}
WP
X!
DCPP
|
X%]
V
iew the load condition status of
the switched power ports
E
S
DCPP
}
W
S
DCPP
|
X8%]
V
iew power use status
E
A
DCPP
}
W
A
DCPP
|
X8^]
Example:
E
A
DCPP
}
W
A
DCPP
|
114
]
Example: the power drawn fr
om all four
switched power output ports is 11.4 watts.
Assign a gr
oup number to a power
port (power output gr
ouping)
E
G
X!
*
X8&
DCPP
}
W
G
X!
%2A
X8&
DCPP
|
DcppG
X!
*
X8&]
V
iew power output gr
ouping
E
G
X!
DCPP
}
W
G
X!
DCPP
|
X8&]
KEY
:
X!
=
Switched power port number:
01-04
= power port 1-4.
X%
=
On/of
f status:
0
= of
f,
1
= on.
X8%
=
Switched output power load status:
0
= ok (total power draw <40 watts),
1
= at limit (total power draw is 40-44 watts),
2
= fault/overload (total power draw >44 watts).
X8^
=
Switched output power use: total power drawn fr
om all power output ports =
nnn
, in tenths of watts.
X8&
=
Switched output power gr
oup:
0
= no gr
oup
1
= gr
oup 1
2
= gr
oup 2.