Performing Soft System Resets (Resets 3, 4, and 5)
Perform a soft reset of the switcher as follows:
1.
Use an Extron Tweeker or other small screwdriver to press and
hold
the rear panel
Reset
button until
Reset
LED blinks the number of times for the desired reset: once
(events reset), twice (system reset), or three times (absolute reset) (see figure 10).
RESET
RESET
RESET
Release, then
immediately
press and release again.
6 seconds
9 seconds
Press and
hold
the button.
3 seconds
Reset LED blinks
once
.
Release, then
immediately
press and release again.
Reset LED blinks
twice
.
Press and
hold
the button.
Press and
hold
the button.
Reset LED blinks
three times.
IP Settings
Reset
Absolute
Reset
Events
Reset
(Mode 5)
(Mode 4)
(Mode 3)
Release, then
immediately
press and release again.
Figure 10.
Soft System Resets
2.
Release the
Reset
button and then immediately press and release the
Reset
button
again. Nothing happens if the second momentary press does not occur within 1
second.
Performing a Hard Reset (Reset 1)
The hard reset function restores the switcher to the base firmware it was shipped with. After
a hard reset, events do not automatically start, but user settings and files are restored.
Perform a hard reset as follows:
NOTE:
The hard reset restores the factory-installed firmware. The switcher reverts
to that factory firmware the next time power is cycled off and on
unless
a firmware
update is performed before the power cycle.
1.
If necessary, turn off power to the switcher.
2.
Press and
hold
the
Reset
button on the rear panel
while
applying AC power to either
switcher power connector.
Troubleshooting
If problems occur while operating the switcher.
1.
Ensure that all devices are plugged in and powered on.
2.
Check to see if one or more outputs are muted.
3.
Ensure an active input is selected for output on the switcher.
4.
Ensure that the proper signal format is supplied.
5.
Check the cabling and make corrections as necessary.
6.
Call the Extron S3 Sales and Technical Support Hotline if necessary (see the contact
numbers on the last page of this guide for the nearest Extron office).