background image

Refer also to the 

Fiber Matrix 6400 Switcher User’s Manual

 at www.extron.com.

Refer also to the 

Fiber Matrix 6400 Switcher User’s Manual

 at www.extron.com.

Making connections

a

 

Fiber optic connectors and LEDs

 —

W

  This unit outputs continuous invisible light, which 

may be harmful and dangerous to the eyes; use with 

caution.  For additional safety, plug the attached dust 

caps into the optical transceivers when the fiber optic 

cable is unplugged.

N

  Ensure that you use the proper fiber cable for your I/O 

board.  Typically, singlemode fiber has a yellow jacket and 

multimode cable has an orange jacket.

N

  The Fiber Matrix 6400 uses one connector on the block as 

an input and the second connector on the same block as a 

separate output.

Ä

 

Input connector —

 

Connect a fiber optic 

cable between each Input 

LC connector and a 

FOX 500 Tx or any other 

compatible Extron FOX 500 

device.

N

  Or, for the FOX 500 serial 

return, (receiver-to-transmitter) 

function, connect the free end 

to the Optical 2 connector on a 

FOX 500 Rx receiver.

 

Input LED —

 When lit, 

the link is active (light is 

received).

Å

 

Output connector —

 

Connect a fiber optic cable 

between each output LC 

connector and a FOX 500 Rx or any 

other compatible Extron FOX 500 

device.

N

  Or, for the FOX 500 serial 

return, (receiver-to-transmitter) 

function, connect the free end 

to the Optical 2 connector 

on a FOX 500 Tx 

transmitter.

 

Output LED —

 This LED is 

always lit.

b

 

BNC connectors —

Ç

 

Multi-rate SDI Input connectors — 

Connect HD-SDI, SDI, 

or 3G-SDI video inputs to these BNC connectors.

É

 

Multi-rate SDI Output connectors —

 Connect digital 

displays to these BNC connectors.

c

 

Ethernet port — 

If desired, connect a network WAN or LAN 

hub, a control system, or a computer to the Ethernet RJ-45 port. 

Network connection

 — Wire as a patch (straight) cable.

 

Computer or control system connection

 — Wire the interface 

cable as a crossover cable.

N

  The factory default IP address is 192.168.254.254.

d

 

Remote port — 

If desired, connect a control system or computer 

to the rear panel Remote RS-232/RS-422 port.

RS-232 Function 

Pin 

Function









— 

TX 

RX 

— 

Gnd 

— 
— 
— 
— 

Not used
Transmit
Receive
Not used
Ground
Not used
Not used
Not used
Not used

TX–

RX–

Gnd

RX+

TX+

Not used
Transmit (–)
Receive (–)
Not used
Ground
Not used
Receive (+)
Transmit (+)
Not used

RS-422

5

1

9

6

Figure 2-6 — 

Audio output connector wiring

e

 

Power connector — 

Plug the switcher into two grounded AC 

sources.

N

  For reliability, connect the Redundant power cord to either 

an uninterruptible power source or to a power source that 

is completely independent from the primary power source.

f

 

Primary and Redundant power supply indicator LEDs —

 

Green — 

Indicates that the associated power supply is 

operating within normal tolerances.

 

Red — 

Indicates that the associated power supply is operating 

outside the normal tolerances or has failed.  See chapter 5, 

“Maintenance and Modifications“ to replace the power supply.

OUT

IN

OPTICAL

2* 1

*

 OPTIONAL FOR

 RETURN DATA

LINK 

LINK 

OPTICAL

FOX 500 Tx

Transmitter

FOX 500 Rx

Receiver

Fiber Matrix

6400

Switcher

1 2*

*

 OPTIONAL FOR

   RETURN DATA

LINK 

LINK

1b

1a

Fiber Matrix 6400 Switcher • Installation

Installation, cont’d

2-4

Fiber Matrix 6400 Switcher • Installation

 

2-5

Summary of Contents for Fiber Matrix 6400

Page 1: ...33 453 4050 Extron Electronics Asia 135 Joo Seng Rd 04 01 PM Industrial Bldg Singapore 368363 800 7339 8766 65 6383 4400 FAX 65 6383 4664 Extron Electronics Japan Kyodo Building 16 Ichibancho Chiyoda...

Page 2: ...den Stromunterbrechung Um das Ger t auf sichere Weise vom Netz zu trennen sollten Sie alle Netzkabel aus der R ckseite des Ger tes aus der externen Stomversorgung falls dies m glich ist oder aus der W...

Page 3: ...ection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in acc...

Page 4: ...or Recalling a Preset 3 3 Locking Out the Front Panel Executive Mode 3 3 Chapter Four Remote Control 4 1 Selected SIS Commands 4 2 Establishing a network Ethernet connection 4 2 Connection timeouts 4...

Page 5: ...er One Introduction About this Manual About the Fiber Matrix 6400 Switchers All trademarks mentioned in this manual are the properties of their respective owners 68 1371 50 Rev A 06 08 ii Fiber Matrix...

Page 6: ...Typical Fiber Matrix 6400 application The Extron proprietary fiber optic signal generated by FOX 500 transmitters can include video stereo audio and transmitter to receiver RS 232 serial communication...

Page 7: ...ptic transceiver modules SDI HD SDI 8x8 I O board equipped with permanent BNC connectors N As listed above two versions of the fiber optic I O boards are documented in this manual They are categorized...

Page 8: ...he fiber optic I O boards locations A through H correspond to the transceiver modules each of which includes an input and an output Therefore locations A through H are numbered from left to right On t...

Page 9: ...video inputs to these BNC connectors Multi rate SDI Output connectors Connect digital displays to these BNC connectors c Ethernet port If desired connect a network WAN or LAN hub a control system or...

Page 10: ...ion port g Configuration port If desired connect a control system or computer to the front panel Configuration RS 232 port Use an optional 9 pin D to 2 5 mm mini jack TRS RS 232 cable part 70 335 01 3...

Page 11: ...unlit state Saving or Recalling a Preset 1 Save a preset Press and hold the Preset button until it flashes PRESET PRESET Preset button blinks Press and hold 2 seconds Save a preset Recall a preset Pr...

Page 12: ...anual at www extron com 4 Chapter Four Remote Control Selected SIS Commands Installing and Starting the Control Program Accessing the HTML Pages Fiber Matrix 6400 Switcher Front Panel Operation Front...

Page 13: ...suing the Query Q command to keep the connection active or disconnecting the socket and reopening the connection when necessary Number of connections A switcher can have up to 200 simultaneous TCP con...

Page 14: ...d video output tie X X Video input X is tied to output X Read audio output tie X X Audio input X is tied to output X Command ASCII command host to switcher Response switcher to host Additional descrip...

Page 15: ...talled 0 No board installed 1 8x8 multimode board 2 8x8 singlemode board 3 SDI HD SDI board x Unknown board or mix of transceivers installed X Firmware version number to second decimal place x xx Comm...

Page 16: ...If the installation program does not self start run Launch exe from the CD 2 Click the Software tab 3 Scroll to the Matrix Switchers program and click Install 4 Follow the on screen instructions The...

Page 17: ...See c on page 2 5 for connection information Loading the start up page N If your Ethernet connection to the matrix switcher is unstable try turning off the proxy server in your Web browser In Microso...

Page 18: ...click OK 6 The switcher downloads the HTML start up page The switcher is ready for operation via HTML remote control 5 Chapter Five Maintenance and Modifications Removing and Installing an I O Board...

Page 19: ...or an I O board disconnect any connected cables 2 Rotate the left and right knurled knobs to completely loosen the captive screws 3 Gently pull on the knurled knobs captive screws to loosen the board...

Page 20: ...wer supply out of the chassis 4 Orient the power supply module to be installed with the LED to the right 5 Align the flanges on the power supply module with the left and right power supply guides see...

Page 21: ...Refer also to the Fiber Matrix 6400 Switcher User s Manual at www extron com Fiber Matrix 6400 Switcher Maintenance and Modifications Maintenance and Modifications cont d 5 6...

Reviews: