Refer also to the
Fiber Matrix 6400 Switcher User’
s Manual
at www
.extron.com.
Refer also to the
Fiber Matrix 6400 Switcher User’
s Manual
at www
.extron.com.
Command
ASCII command
(host to switcher)
Response
(switcher to host)
Additional description
Create ties
N
• Commands can be entered back-to-back in a string, with no spaces. For example: 1*1!02*02&003*003%4*24$.
•
The matrix switchers support 1-, 2-, and 3-digit numeric entries (1*1!, 02*02&, or 003*003%).
N
The &
tie
command for RGB and the %
tie
command for video can be used interchangeably.
N
The &
read tie
command for RGB and the %
read tie
command for video can be used interchangeably.
Tie input
X!
to output
X@
,
video
and audio
X!
*
X@
!
Out
X@
•
In
X!
•
All
]
Tie input
X!
‘s video and audio to output
X@
.
Example:
1*3!
Out03
•
In01
•
All
]
Tie input 1 video and audio to output 3.
Tie input
X!
to output
X@
, RGBHV
only
X!
*
X@
&
Out
X@
•
In
X!
•
RGB
]
Audio breakaway.
Example:
(see 2nd Note, above)
10*4&
Out04
•
In10
•
RGB
]
Tie input 10 RGB to output 4.
Tie input
X!
to output
X@
, video
only
X!
*
X@
%
Out
X@
•
In
X!
•
Vid
]
Audio breakaway.
Example:
(see 2nd Note, above)
7*5%
Out05
•
In07
•
Vid
]
Tie input 7 video to output 5.
Tie input
X!
to output
X@
, audio
only
X!
*
X@
$
Out
X@
•
In
X!
•
Aud
]
Audio breakaway.
Example:
24*04$
Out04
•
In24
•
Aud
]
Tie input 24 audio to output 4.
Read RGB output tie
X@
&
X!]
RGBHV input
X!
is tied to output
X@
.
Read video output tie
X@
%
X!]
Video input
X!
is tied to output
X@
.
Read audio output tie
X@
$
X!]
Audio input
X!
is tied to output
X@
.
Command
ASCII command
(host to switcher)
Response
(switcher to host)
Additional description
Channel mute commands
Channel mute
X@
*1B
Vmt
X@
*1
]
Mute output
X@
(no signal is output, but
the light output remains active).
Channel unmute
X@
*0B
Vmt
X@
*0
]
Unmute output
X@
(signal is output).
Read channel mute
X@
B
X#]
1 = mute on, 0 = mute off.
Global channel mute
1*B
Vmt1
]
Mute all audio outputs.
Global channel unmute
0*B
Vmt0
]
Unmute all audio outputs.
View output mutes
E
VM
}
X#
1
,
X#
2
, ...
X#
n
]
Each
X#
response is the mute status of an
output, starting from output 1.
n
= the maximum number of outputs for
your configuration.
Save and recall presets
N
If you try to recall a preset that is not saved, the matrix switcher responds with the error code
E11.
Save current configuration as a
global preset
X$
,
Spr
X$]
Command character is a comma.
Example:
9
,
Spr09
]
Save current ties as preset 9.
Recall a global preset
X$
.
Rpr
X$]
Command character is a period.
Example:
5
.
Rpr05
]
Recall preset 5, which becomes the current
configuration.
N
X!
= Input number
00 – (maximum number of inputs for your configuration) (00 = untied)
X@
= Output number
01 – (maximum number of outputs for your configuration)
N
X@
= Output number
01 – (maximum number of inputs for your model)
X#
= Mute
0 = not muted, 1 = muted
X$
= Global or room preset #
0 - 32
Fiber Matrix 6400 Switcher • Remote Contr
ol
Remote Contr
ol, cont’d
4-4
Fiber Matrix 6400 Switcher • Remote Contr
ol
4-5