Operation, cont’d
CrossPoint 300 Matrix Switchers • Operation
3-22
2
.
Press and hold the Preset button for approximately 2 seconds until the Preset
LED blinks (figure 3-34).
PRESET
PRESET
1
2
3
4
Press and hold the Preset button until the
Preset LED blinks.
Release the
Preset button.
2 seconds
All input and output LEDs with assigned presets light.
If you then save the configuration to a lit preset number,
the configuration data at that preset location will be overwritten.
Lit
(Preset Assigned)
Unlit
(Preset Unassigned)
= Blinking LED
Preset 17
Preset 18
Preset 20
Preset 19
Figure 3-34 — Enter
Save Preset
mode
3
.
Press and release the Output 1 button (figure 3-35).
ENTER PRESET VIEW
CONTROL
1
2
3
4
The Enter LED blinks to indicate
the need to save the preset.
The Preset LED continues to blink.
Press and release the Output 1 button.
The LED blinks to indicate that this preset
number is selected but not saved.
= Blinking LED
Preset 17
Preset 18
Preset 20
Preset 19
Figure 3-35 — Select the preset
4
.
Press and release the Enter button (figure 3-36). The current configuration is
now stored in memory location 17.
ENTER PRESET VIEW
ESC
CONTROL
The Enter and Preset LEDs
return to the unlit state.
Press the Enter button to
save the preset.
All input LEDs
return to the
unlit state.
Figure 3-36 — Press the Enter button
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201
Fax 07131 911203