ATTENTION

:

• 

Always use a power supply supplied or specified by Extron. Use of an unauthorized power supply voids all regulatory 
compliance certification and may cause damage to the supply and the unit. 

• 

Utilisez toujours une source d’alimentation fournie par Extron. L’utilisation d’une source d’alimentation non autorisée 
annule toute conformité réglementaire et peut endommager la source d’alimentation ainsi que l’unité.

• 

If not provided with a power supply, this product is intended to be supplied by a UL Listed power source marked 
“Class 2” or “LPS” and rated output 12 VDC, minimum 1.0 A.

• 

Si ce produit ne dispose pas de sa propre source d’alimentation électrique, il doit être alimenté par une source 
d’alimentation certifiée UL de classe 2 ou LPS et paramétré à 12 VDC et 1,0 A minimum.

• 

Unless otherwise stated, the AC/DC adapters are not suitable for use in air handling spaces or in wall cavities.

• 

Sauf mention contraire, les adaptateurs AC/DC ne sont pas appropriés pour une utilisation dans les espaces d’aération 
ou dans les cavités murales.

• 

The installation must always be in accordance with the applicable provisions of National Electrical Code ANSI/NFPA 70, 
article 725 and the Canadian Electrical Code part 1, section 16. The power supply shall not be permanently fixed to 
building structure or similar structure.

• 

Cette installation doit toujours être en accord avec les mesures qui s’applique au National Electrical Code ANSI/
NFPA 70, article 725, et au Canadian Electrical Code, partie 1, section 16. La source d’alimentation ne devra pas être 
fixée de façon permanente à une structure de bâtiment ou à une structure similaire.

eBUS 24 WATTS MAX

100-240V       50-60Hz

0.6A MAX

+ V + S

G

– S

+ V + S

G

– S

+ V + S

G

– S

+ V + S

G

– S

+ V + S

G

– S

+ V + S

G

– S

ACP port on 
another ACP 
endpoint 
device

V

+

 S

G

– S

LAN

DMP 128 Plus C

Rx

Tx

G

RS-232

+S

+V

-S G

5

6

7

8

1

2

3

4

OUTPUTS

DMP EXP

ACP

REMOTE

USB AUDIO

RESET

DMP 128 Plus

X

G

-S

+S

G

-S

+S

Tie drain wires 

to ground.

G

-S

+S

X

G

-S

+S

+V

Ground

+

 Signal

-

 Signal

+

12 VDC

G

-S

+S

+V

Power Input

(100-240 VAC, 

50-60 Hz)

PS 1220EB

ATTENTION:

 

Do NOT connect the power 

pin to any device that is already powered 
by the DMP 128 Plus control processor 
or by an additional power supply.

3/16" (5 mm) Max.

ACP Connections

• Connect up to eight (8) ACP 

endpoint devices to the PS 1220EB.

• Wire the connectors the same at 

both ends.

• All ports are identical and 

interchangeable.

Summary of Contents for ACP 105 EU/MK

Page 1: ...ng an ACP system installation consider how many ACP panels to use maximum cable distance and mounting see the ACP 105 EU and ACP 105 MK product pages at www extron com for more information regarding the ACP 105 EU MK Front and Rear Panel Features SOURCE 1 V ACP PWR LOAD 1 5W S S G V S S G R STATUS GREEN AMBER RED LINK COM ERROR ID ERROR SOURCE 2 SOURCE 3 SOURCE 4 SOURCE 5 A A B B C C D D E E Figur...

Page 2: ...ty of the button panel such as height from the floor distance from obstructions and how far a user must reach to press the buttons For guidelines see sections 307 Protruding Objects and 308 Reach Ranges of the 2010 ADA Standards for Accessible Design available at http www ada gov regs2010 2010ADAStandards 2010ADAStandards pdf Site Preparation Extron offers an assortment of mud rings optional UL Li...

Page 3: ...bus ID If multiple panels have the same bus ID address conflicts may cause one or more of the panels to not be recognized in DSP Configurator or by the host device Up to eight ACP devices can be connected in the same system V ACP S S G V S S G R PWR LOAD 1 5W STATUS GREEN AMBER RED LINK COM ERROR ID ERROR V S G S 0 1 0 0 1 0 ON 1 2 3 4 5 6 0 0 0 0 0 1 1 ON 1 2 3 4 5 6 18 Unit address DIP switches ...

Page 4: ...captive screw connector to each end of the cable wiring both ends the same In most cases ACP devices are powered by the host device Power is carried on the V pin of the ACP 105 EU MK and other ACP devices Extron STP20 2 1000 or STP20 2P 100 cable is recommended for ACP device connections ACP devices that are relatively far from the host device can be connected to an optional Extron PS 1220EB eBUS ...

Page 5: ... be in accordance with the applicable provisions of National Electrical Code ANSI NFPA 70 article 725 and the Canadian Electrical Code part 1 section 16 The power supply shall not be permanently fixed to building structure or similar structure Cette installation doit toujours être en accord avec les mesures qui s applique au National Electrical Code ANSI NFPA 70 article 725 et au Canadian Electric...

Page 6: ...sh the configuration file to the device Step 7 Test and Troubleshoot 1 Verify the ACP bus ID DIP switches are set to the desired address on each unit and that there are no bus ID address conflicts in the system As mentioned in the rear panel features diagram in step 4 see page 3 the ACP LED lights green when power and communication are present and there are no bus ID address conflicts Refer to the...

Page 7: ...ided by the manufacturer see 1 in the figure to the right NOTES The metal mounting brackets provided with the EU and MK models are different and are not interchangeable Ensure the bracket is in the correct orientation with the side marked Front facing away from the wall The EU model is attached with screws at the top and bottom The MK model is attached with screws on both sides 3 Disconnect power ...

Page 8: ...ed by the manufacturer 2 If required align the screw holes of the provided spacer with the holes in the electrical box 2 3 Align the screw holes in the metal mounting bracket with the holes in the spacer and electrical box 3 NOTE Ensure that the front surface of the mounting bracket is facing out away from the wall 4 Use the two provided screws to secure the metal mounting bracket and spacer to th...

Reviews: