System (CPU and Backplane) Health Check
Advanced System Diagnostics and Troubleshooting Guide
75
To clarify the relationship between MSM ports, the backplane links, and the I/O module slots shown in
Example 1, consider the following annotated adaptation of the example’s output (not actual command
output; for instructional purposes only):
MSM Module
Port Channel Slot
------- ------- ------
Port 1: (chan0, slot1) 6140 6140...
Port 2: (chan0, slot2) 0 0...
Port 3: (chan0, slot3) 0 0...
Port 4: (chan0, slot4) 0 0...
Port 5: (chan0, slot5) 0 0...
Port 6: (chan0, slot6) 0 0...
Port 7: (chan0, slot7) 214020 214020...
Port 8: (chan0, slot8) 214010 214010...
Port 9: (chan1, slot1) 6140 6140...
Port 10: (chan1, slot2) 0 0...
Port 11: (chan1, slot3) 0 0...
Port 12: (chan1, slot4) 0 0...
Port 13: (chan1, slot5) 0 0...
Port 14: (chan1, slot6) 0 0...
Port 15: (chan1, slot7) 214020 214020...
Port 16: (chan1, slot8) 214010 214010...
Port 17: (chan2, slot1) 6140 6140...
Port 18: (chan2, slot2) 0 0...
Port 19: (chan2, slot3) 0 0...
Port 20: (chan2, slot4) 0 0...
Port 21: (chan2, slot5) 0 0...
Port 22: (chan2, slot6) 0 0...
Port 23: (chan2, slot7) 214020 214020...
Port 24: (chan2, slot8) 214010 214010...
Port 25: (chan3, slot1) 6140 6140...
Port 26: (chan3, slot2) 0 0...
Port 27: (chan3, slot3) 0 0...
Port 28: (chan3, slot4) 0 0...
Port 29: (chan3, slot5) 0 0...
Port 30: (chan3, slot6) 0 0...
Port 31: (chan3, slot7) 214020 214020...
Port 32: (chan3, slot8) 214010 214010...
The report in Example 1 shows 32 ports from the MSM switch fabric to the backplane; four channels;
four MSM ports to each BlackDiamond 6808 I/O module slot.
In this example, chassis slots 1, 7, and 8 are populated with I/O modules capable of responding to the
backplane health check packets from the system health checker. Tx and Rv packet values indicate the
presence of a module, so—for example—MSM ports 1, 9, 17, and 25 are the MSM ports to I/O module
slot 1, MSM ports 7, 15, 23, and 31 are the MSM ports to I/O module slot 7, and MSM ports 8, 16, 24,
and 32 are the MSM ports to I/O module slot 8.
MSM ports 1 through 8 are the first channel (channel0) to each I/O module slot, MSM ports 9 through
16 are the second channel (channel1) to each I/O module slot, and so forth. In this example, no failures
appear for any of these channels.
In this example, I/O module slot 1 has fewer reported diagnostics packets sent because it recently had
extended diagnostics run against it, which reset the counter.
Summary of Contents for ExtremeWare Version 7.8
Page 8: ...8 Advanced System Diagnostics and Troubleshooting Guide Contents...
Page 14: ...14 Advanced System Diagnostics and Troubleshooting Guide Introduction...
Page 24: ...24 Advanced System Diagnostics and Troubleshooting Guide i Series Switch Hardware Architecture...
Page 48: ...48 Advanced System Diagnostics and Troubleshooting Guide Software Exception Handling...
Page 102: ...102 Advanced System Diagnostics and Troubleshooting Guide Additional Diagnostics Tools...
Page 110: ...110 Advanced System Diagnostics and Troubleshooting Guide Troubleshooting Guidelines...
Page 120: ...120 Advanced System Diagnostics and Troubleshooting Guide Index...