Viewing hardware information
About this task
Perform the following procedure to view system status and technical information about the VSP
4450GTX-HT-PWR+ hardware components. You can view information about the switch (such as
location), chassis (type, serial number, and base MAC address), temperature, power supplies, fans,
cards, system errors, port locks, topology status, and message control information.
Procedure
1. Log on to the switch to enter User EXEC mode.
2. View hardware information:
show sys-info [card | fan | led | power | temperature | uboot]
Example
Viewing hardware information on VSP 4450GTX-HT-PWR+ switch:
VSP-4450GTXHT-PWR+:1>show sys-info
General Info :
SysDescr : VSP-4450GTXHT-PWR+ (w.x.y.z)
SysName : VSP-4450GTXHT-PWR+
SysUpTime : 0 day(s), 00:05:40
SysContact : http://www.extremenetworks.com/contact/
SysLocation : 9 Northeastern Blvd,Salem,NH. 03079
Chassis Info:
Chassis : 4450GTXHT-PWR+
ModelName : 4450GTXHT-PWR+
BrandName : Extreme Networks.
Serial# : SDNIVSP4450B020
H/W Revision : R0B
H/W Config : none
Part Number :
NumSlots : 1
NumPorts : 50
BaseMacAddr : b0:ad:aa:55:1b:00
MacAddrCapacity : 256
System MTU : 1950
Card Info :
Slot# CardType Serial# Part# Oper Admin Power
Status Status State
1 4450GTXHT-PWR+ SDNIVSP4450B020 -- up up on
Temperature Info :
Chassis Temperature
32
Power Supply Info :
Ps#1 Status : UP
Ps#1 Type : AC
Ps#1 Description : AC-DC-54V-1000W
Ps#1 Serial Number: LBNNTMPL83000H
Ps#1 Version : --
Ps#1 Part Number : 700508300
Ps#2 Status : empty
Total Power Available : 1000 watts
Total Power Usage : 145 watts
Installing the VSP 4450GTX-HT-PWR+
August 2018
Installing the Virtual Services Platform 4450GTX-HT-PWR+
36