Important:
The VSP 4000 series has no AC power switch. When you connect the power cord to a suitable,
energized AC power outlet, the switch powers up immediately.
Figure 5: Connecting AC power to the front panel
Warning:
Disconnecting the AC power cord is the only way to turn off AC power to the VSP 4000. Always
connect the AC power cord in a quickly and safely accessible location in case of an emergency.
For a translation of this statement, see
Translations of safety messages
on page 39.
Caution:
Before you unplug the AC power cord, always perform the following shutdown procedure. This
procedure flushes any pending data to ensure data integrity.
1. Enter the Privileged EXEC command mode:
enable
2. Shutdown the VSP 4000:
sys shutdown
3. When prompted, enter
y
to confirm system shut down.
4. Before you unplug the power cord, wait until you see the following message:
System Halted, OK to turn off power.
Example
VSP-4450GSX-PWR+:1>enable
VSP-4450GSX-PWR+:1#sys shutdown
Are you sure you want shutdown the system? Y/N (y/n) ? y
CP1 [03/24/14 18:39:04.932:UTC] 0x00010813 00000000 GlobalRouter HW INFO
System shutdown initiated from CLI
CP1 [03/24/14 18:39:06.000] LifeCycle: INFO: Stopping all processes
Connect AC power
August 2018
Installing the Virtual Services Platform 4450GTX-HT-PWR+
31