background image

including any code and software unless expressly authorized by

Extreme Networks. Unauthorized reproduction, transmission,

dissemination, storage, and or use without the express written

consent of Extreme Networks can be a criminal, as well as a civil

offense under the applicable law.

Virtualization

The following applies if the product is deployed on a virtual machine.

Each product has its own ordering code and license types. Note,

unless otherwise stated, that each Instance of a product must be

separately licensed and ordered. For example, if the end user

customer or Extreme Networks Channel Partner would like to install

two Instances of the same type of products, then two products of that

type must be ordered.

Third Party Components

“Third Party Components” mean certain software programs or

portions thereof included in the Software or Hosted Service may

contain software (including open source software) distributed under

third party agreements (“Third Party Components”), which contain

terms regarding the rights to use certain portions of the Software

(“Third Party Terms”). As required, information regarding distributed

Linux OS source code (for those products that have distributed Linux

OS source code) and identifying the copyright holders of the Third

Party Components and the Third Party Terms that apply is available

in the products, Documentation or on Extreme Networks’ website

at:

http://www.extremenetworks.com/support/policies/software-

licensing 

or such successor site as designated by Extreme Networks.

The open source software license terms provided as Third Party

Terms are consistent with the license rights granted in these Software

License Terms, and may contain additional rights benefiting You,

such as modification and distribution of the open source software.

The Third Party Terms shall take precedence over these Software

License Terms, solely with respect to the applicable Third Party

Components to the extent that these Software License Terms impose

greater restrictions on You than the applicable Third Party Terms.

The following applies only if the H.264 (AVC) codec is distributed with

the product. THIS PRODUCT IS LICENSED UNDER THE AVC

PATENT PORTFOLIO LICENSE FOR THE PERSONAL USE OF A

CONSUMER OR OTHER USES IN WHICH IT DOES NOT RECEIVE

REMUNERATION TO (i) ENCODE VIDEO IN COMPLIANCE WITH

THE AVC STANDARD (“AVC VIDEO”) AND/OR (ii) DECODE AVC

VIDEO THAT WAS ENCODED BY A CONSUMER ENGAGED IN A

PERSONAL ACTIVITY AND/OR WAS OBTAINED FROM A VIDEO

PROVIDER LICENSED TO PROVIDE AVC VIDEO. NO LICENSE IS

GRANTED OR SHALL BE IMPLIED FOR ANY OTHER USE.

ADDITIONAL INFORMATION MAY BE OBTAINED FROM MPEG LA,

L.L.C. SEE 

HTTP://WWW.MPEGLA.COM

.

Service Provider

THE FOLLOWING APPLIES TO EXTREME NETWORKS CHANNEL

PARTNER’S HOSTING OF EXTREME NETWORKS PRODUCTS

OR SERVICES. THE PRODUCT OR HOSTED SERVICE MAY USE

THIRD PARTY COMPONENTS SUBJECT TO THIRD PARTY

TERMS AND REQUIRE A SERVICE PROVIDER TO BE

INDEPENDENTLY LICENSED DIRECTLY FROM THE THIRD

PARTY SUPPLIER. AN EXTREME NETWORKS CHANNEL

PARTNER’S HOSTING OF EXTREME NETWORKS PRODUCTS

MUST BE AUTHORIZED IN WRITING BY EXTREME NETWORKS

AND IF THOSE HOSTED PRODUCTS USE OR EMBED CERTAIN

THIRD PARTY SOFTWARE, INCLUDING BUT NOT LIMITED TO

MICROSOFT SOFTWARE OR CODECS, THE EXTREME

NETWORKS CHANNEL PARTNER IS REQUIRED TO

INDEPENDENTLY OBTAIN ANY APPLICABLE LICENSE

AGREEMENTS, AT THE EXTREME NETWORKS CHANNEL

PARTNER’S EXPENSE, DIRECTLY FROM THE APPLICABLE

THIRD PARTY SUPPLIER.

WITH RESPECT TO CODECS, IF THE EXTREME NETWORKS

CHANNEL PARTNER IS HOSTING ANY PRODUCTS THAT USE

OR EMBED THE G.729 CODEC, H.264 CODEC, OR H.265

CODEC, THE EXTREME NETWORKS CHANNEL PARTNER

ACKNOWLEDGES AND AGREES THE EXTREME NETWORKS

CHANNEL PARTNER IS RESPONSIBLE FOR ANY AND ALL

RELATED FEES AND/OR ROYALTIES. THE G.729 CODEC IS

LICENSED BY SIPRO LAB TELECOM INC. SEE 

WWW.SIPRO.COM/CONTACT.HTML

. THE H.264 (AVC) CODEC IS

LICENSED UNDER THE AVC PATENT PORTFOLIO LICENSE FOR

THE PERSONAL USE OF A CONSUMER OR OTHER USES IN

WHICH IT DOES NOT RECEIVE REMUNERATION TO: (I) ENCODE

VIDEO IN COMPLIANCE WITH THE AVC STANDARD (“AVC

VIDEO”) AND/OR (II) DECODE AVC VIDEO THAT WAS ENCODED

BY A CONSUMER ENGAGED IN A PERSONAL ACTIVITY AND/OR

WAS OBTAINED FROM A VIDEO PROVIDER LICENSED TO

PROVIDE AVC VIDEO. NO LICENSE IS GRANTED OR SHALL BE

IMPLIED FOR ANY OTHER USE. ADDITIONAL INFORMATION

FOR H.264 (AVC) AND H.265 (HEVC) CODECS MAY BE

OBTAINED FROM MPEG LA, L.L.C. SEE 

HTTP://

WWW.MPEGLA.COM

.

Compliance with Laws

You acknowledge and agree that it is Your responsibility for

complying with any applicable laws and regulations, including, but not

limited to laws and regulations related to call recording, data privacy,

intellectual property, trade secret, fraud, and music performance

rights, in the country or territory where the Extreme Networks product

is used.

Preventing Toll Fraud

“Toll Fraud” is the unauthorized use of your telecommunications

system by an unauthorized party (for example, a person who is not a

corporate employee, agent, subcontractor, or is not working on your

company's behalf). Be aware that there can be a risk of Toll Fraud

associated with your system and that, if Toll Fraud occurs, it can

result in substantial additional charges for your telecommunications

services.

Security Vulnerabilities

Information about Extreme Networks’ security support policies can be

found in the Global Technical Assistance Center Knowledgebase at 

https://gtacknowledge.extremenetworks.com/

.

Downloading Documentation

For the most current versions of Documentation, see the Extreme

Networks Support website: 

http://

documentation.extremenetworks.com

, or such successor site as

designated by Extreme Networks.

Contact Extreme Networks Support

See the Extreme Networks Support website:

http://

www.extremenetworks.com/support

 for product or Hosted Service

notices and articles, or to report a problem with your Extreme

Networks product or Hosted Service. For a list of support telephone

numbers and contact addresses, go to the Extreme Networks

Support website:

http://www.extremenetworks.com/support/contact/

(or such successor site as designated by Extreme Networks), scroll

to the bottom of the page, and select Contact Extreme Networks

Support.

Trademarks

The trademarks, logos and service marks (“Marks”) displayed in this

site, the Documentation, Hosted Service(s), and product(s) provided

by Extreme Networks are the registered or unregistered Marks of

Extreme Networks, Inc., its affiliates, its licensors, its suppliers, or

other third parties. Users are not permitted to use such Marks without

prior written consent from Extreme Networks or such third party

which may own the Mark. Nothing contained in this site, the

Documentation, Hosted Service(s) and product(s) should be

construed as granting, by implication, estoppel, or otherwise, any

license or right in and to the Marks without the express written

permission of Extreme Networks or the applicable third party.

Extreme Networks is a registered trademark of Extreme Networks,

Inc.

All non-Extreme Networks trademarks are the property of their

respective owners. Linux

®

 is the registered trademark of Linus

Torvalds in the U.S. and other countries.

For additional information on Extreme Networks trademarks, please

see: 

http://www.extremenetworks.com/company/legal/

Summary of Contents for EC4400A03-E6

Page 1: ...Installing the Virtual Services Platform 4450GTX HT PWR 9035362 Rev 02 August 2018...

Page 2: ...HE TERMS OF USE IF YOU ARE ACCEPTING THE TERMS OF USE ON BEHALF A COMPANY OR OTHER LEGAL ENTITY YOU REPRESENT THAT YOU HAVE THE AUTHORITY TO BIND SUCH ENTITY TO THESE TERMS OF USE IF YOU DO NOT HAVE S...

Page 3: ...ER IS HOSTING ANY PRODUCTS THAT USE OR EMBED THE G 729 CODEC H 264 CODEC OR H 265 CODEC THE EXTREME NETWORKS CHANNEL PARTNER ACKNOWLEDGES AND AGREES THE EXTREME NETWORKS CHANNEL PARTNER IS RESPONSIBLE...

Page 4: ...cal specifications 19 Environmental requirements 19 Airflow direction 20 Package contents 20 Installing the Virtual Services Platform 4000 on a table or shelf 21 Installing the Virtual Services Platfo...

Page 5: ...ED state indicators 33 Port LED state indicators 34 Viewing hardware information 36 Chapter 6 Translations of safety messages 39 Contents August 2018 Installing the Virtual Services Platform 4450GTX H...

Page 6: ...as for improvements to our documentation so you can find the information you need faster Broken links or usability issues If you would like to provide feedback to the Extreme Networks Information Deve...

Page 7: ...on of your network environment such as layout cable type other relevant environmental information Network load at the time of trouble if known The device history for example if you have returned the d...

Page 8: ...pe your first and last name 3 Type the name of your company 4 Type your email address 5 Type your job title 6 Select the industry in which your company operates 7 Confirm your geographic information i...

Page 9: ...2 New in this document There are no feature related changes for this release in Installing the Virtual Services Platform 4450GTX HT PWR August 2018 Installing the Virtual Services Platform 4450GTX HT...

Page 10: ...e 11 Management port Extreme Networks Virtual Services Platform 4000 Series requires one port to be configured as the management port This port separates user traffic from management traffic in highly...

Page 11: ...the correct power cord for your region For more information see Power cord types and order codes on page 11 Table 2 Power supply order codes VSP 4000 PSU Usage Part number order code 1000W AC POE pow...

Page 12: ...switch as they are certified and qualified as high temperature devices However if you use a non high temperature SFP device the device is logged as an unsupported high temperature device Extreme Netw...

Page 13: ...orks does not provide support for operational issues related to these transceivers but they will operate and the port link will come up The switch logs the device as an unsupported or unknown device F...

Page 14: ...ave the following tools and cables Phillips 2 screwdriver RJ45 console port cable ESD cable See Cable requirements for the VSP 4000 on page 24 4 Unpack the equipment Observe ESD precautions when you u...

Page 15: ...escription in the area The ground path must be permanent and must not exceed 1 Ohm of resistance from the rack to the grounding electrode August 2018 Installing the Virtual Services Platform 4450GTX H...

Page 16: ...tion of AC input and DC input power supplies in the same chassis is not supported For the procedure to install power supply see Installing the VSP 4000 Series PWR power supply on page 27 3 Check the L...

Page 17: ...age Electrostatic discharge ESD is a discharge of stored static electricity that can damage equipment and impair electrical circuitry Electrostatic voltages can result from friction including pulling...

Page 18: ...able installations With new cable installations you are recommended to use an ESD discharge cable to reduce the potential for damage from static that can build up in cables The following figure illust...

Page 19: ...switches in this series Ensure that the area where you install the switch and where it operates meets these requirements Table 6 Virtual Services Platform 4000 environmental requirements Environmental...

Page 20: ...page 39 Airflow direction The airflow direction in the VSP 4450GTX HT PWR for the top half of the switch where the components exist is from left to right as viewed from the front Cool air enters the...

Page 21: ...orm 4000 on a table or shelf You can install a single VSP 4000 switch on any flat surface The surface must support the combined weight of the switch and attached cables from 15 and 20 pounds 7 to 9 ki...

Page 22: ...e used by the power service in the area The ground path must be permanent and must not exceed 1 Ohm of resistance from the rack to the grounding electrode Caution When you mount the device in a rack d...

Page 23: ...itch into the rack as illustrated 3 Insert and tighten the rack mount screws Installing the Virtual Services Platform 4000 in an equipment rack August 2018 Installing the Virtual Services Platform 445...

Page 24: ...orted in SFP ports only and not in SFP ports Console Port Varies depending on the user device The VSP 4000 has an RJ45 female connector so a serial cable with RJ45 connectors or a serial cable with a...

Page 25: ...rforming this procedure 1 Disconnect the network fiber cable from the transceiver 2 Use the locking mechanism on the transceiver to release it The locking mechanism varies from model to model as illus...

Page 26: ...ot used 2 Transmit Data TXD 3 Receive Data RXD 4 Data terminal ready not used 5 Signal ground GND 6 Not used 7 Request to send not used 8 Not used 9 Ring indicator not used Table 9 RJ45 Console port p...

Page 27: ...d in the slot Secure the power supply with the two thumb screws Note The switch chassis can prevent an incorrect installation of a power supply If you insert a power supply upside down it will not ful...

Page 28: ...Connector The 1000W AC power supply uses an IEC 60320 C16 AC power cord connector The AC power cord is in close proximity to the hot air exhaust and supports high operating temperatures Figure 4 IEC 6...

Page 29: ...r specifications are based on the maximum rated capacity of the power supplies and are not based on typical power consumption which is lower Table 13 AC power specifications 4450GTX HT PWR Input Curre...

Page 30: ...50 60 Hz Single phase United Kingdom BS1363 male plug with fuse Harmonized cord 240VAC 50 Hz Single phase Australia AS3112 1981 male plug 240VAC 50 Hz Single phase Danger Using power cords with a pro...

Page 31: ...ys perform the following shutdown procedure This procedure flushes any pending data to ensure data integrity 1 Enter the Privileged EXEC command mode enable 2 Shutdown the VSP 4000 sys shutdown 3 When...

Page 32: ...c mounts No such file or directory Deconfiguring network interfaces done Stopping syslogd klogd no syslogd found none killed Sending all processes the TERM signal Sending all processes the KILL signal...

Page 33: ...emit laser or infrared light that can injure your eyes Never look into an optical fiber or connector port Always assume that fiber optic cables are connected to a light source For a translation of th...

Page 34: ...en blinking The switch is connected to a secondary power supply but the power input is disconnected Amber solid The power supply in slot 1 or slot 2 was removed after operating Amber blinking The powe...

Page 35: ...P transceiver Port LED state indicators Label Color and Status Description In Use Green Blink Not applicable Green Steady The SFP SFP port and the transmit port are active Amber Blink Not applicable A...

Page 36: ...Name VSP 4450GTXHT PWR SysUpTime 0 day s 00 05 40 SysContact http www extremenetworks com contact SysLocation 9 Northeastern Blvd Salem NH 03079 Chassis Info Chassis 4450GTXHT PWR ModelName 4450GTXHT...

Page 37: ...s Trap false Send Authentication Trap false Error Code 0 Error Severity 0 Port Lock Info Status off LockedPorts Message Control Info Action suppress msg Control Interval 5 Max msg num 5 Status disable...

Page 38: ...Displays LED information in detail power Displays information about installed power supplies temperature Displays temperature information uboot Displays uboot details Installing the VSP 4450GTX HT PW...

Page 39: ...baie ne l empilez pas directement sur un autre Chaque module doit tre fix sa propre baie l aide des supports de montage appropri s Ces supports ne sont pas con us pour r sister plusieurs modules Impor...

Page 40: ...ns une baie veillez laisser la plaque m tallique sur la baie Si vous la retirez l a ration du module ne peut pas s effectuer correctement Important Precaution Si no instala ning n m dulo en la ranura...

Page 41: ...der facilement en cas d urgence Important Advertencia Para apagar el dispositivo debe desenchufar el cable Conecte siempre el cable de alimentaci n a una toma segura y de f cil acceso por si se produ...

Page 42: ...messa a terra Senza un adeguata messa a terra chiunque tocchi lo switch corre il rischio di ricevere una scossa elettrica L assenza di un percorso per la messa a terra verso lo switch pu comportare u...

Page 43: ...t cnico de Extreme Networks si necesita asistencia para cambiar la bater a Important Aviso A bateria de l tio n o substitu vel em campo S deve ser removida e substitu da por pessoal autorizado Entre...

Reviews: