background image

©

 2017-2018, Extreme Networks, Inc.

All Rights Reserved.

Notice

While reasonable efforts have been made to ensure that the

information in this document is complete and accurate at the time of

printing, Extreme Networks, Inc. assumes no liability for any errors.

Extreme Networks, Inc. reserves the right to make changes and

corrections to the information in this document without the obligation

to notify any person or organization of such changes.

Documentation disclaimer

“Documentation” means information published in varying mediums

which may include product information, operating instructions and

performance specifications that are generally made available to users

of products. Documentation does not include marketing materials.

Extreme Networks shall not be responsible for any modifications,

additions, or deletions to the original published version of

Documentation unless such modifications, additions, or deletions

were performed by or on the express behalf of Extreme Networks.

End User agrees to indemnify and hold harmless Extreme Networks,

Extreme Networks’ agents, servants and employees against all

claims, lawsuits, demands and judgments arising out of, or in

connection with, subsequent modifications, additions or deletions to

this documentation, to the extent made by End User.

Link disclaimer

Extreme Networks is not responsible for the contents or reliability of

any linked websites referenced within this site or Documentation

provided by Extreme Networks. Extreme Networks is not responsible

for the accuracy of any information, statement or content provided on

these sites and does not necessarily endorse the products, services,

or information described or offered within them. Extreme Networks

does not guarantee that these links will work all the time and has no

control over the availability of the linked pages.

Warranty

Extreme Networks provides a limited warranty on Extreme Networks

hardware and software. Refer to your sales agreement to establish

the terms of the limited warranty. In addition, Extreme Networks’

standard warranty language, as well as information regarding support

for this product while under warranty is available to Extreme

Networks customers and other parties through the Extreme Networks

Support website: 

http://www.extremenetworks.com/support

 under the

link ““Policies” or such successor site as designated by Extreme

Networks. Please note that if You acquired the product(s) from an

authorized Extreme Networks Channel Partner outside of the United

States and Canada, the warranty is provided to You by said Extreme

Networks Channel Partner and not by Extreme Networks.

“Hosted Service” means an Extreme Networks hosted service

subscription that You acquire from either Extreme Networks or an

authorized Extreme Networks Channel Partner (as applicable) and

which is described further in Hosted SAS or other service description

documentation regarding the applicable hosted service. If You

purchase a Hosted Service subscription, the foregoing limited

warranty may not apply but You may be entitled to support services

in connection with the Hosted Service as described further in your

service description documents for the applicable Hosted Service.

Contact Extreme Networks or Extreme Networks Channel Partner (as

applicable) for more information.

Hosted Service

THE FOLLOWING APPLIES ONLY IF YOU PURCHASE AN

EXTREME NETWORKS HOSTED SERVICE SUBSCRIPTION

FROM EXTREME NETWORKS OR AN EXTREME NETWORKS

CHANNEL PARTNER (AS APPLICABLE), THE TERMS OF USE

FOR HOSTED SERVICES ARE AVAILABLE ON THE EXTREME

NETWORKS WEBSITE, 

https://extremeportal.force.com

 OR SUCH

SUCCESSOR SITE AS DESIGNATED BY EXTREME NETWORKS,

AND ARE APPLICABLE TO ANYONE WHO ACCESSES OR USES

THE HOSTED SERVICE. BY ACCESSING OR USING THE

HOSTED SERVICE, OR AUTHORIZING OTHERS TO DO SO, YOU,

ON BEHALF OF YOURSELF AND THE ENTITY FOR WHOM YOU

ARE DOING SO (HEREINAFTER REFERRED TO

INTERCHANGEABLY AS “YOU” AND “END USER”), AGREE TO

THE TERMS OF USE. IF YOU ARE ACCEPTING THE TERMS OF

USE ON BEHALF A COMPANY OR OTHER LEGAL ENTITY, YOU

REPRESENT THAT YOU HAVE THE AUTHORITY TO BIND SUCH

ENTITY TO THESE TERMS OF USE. IF YOU DO NOT HAVE SUCH

AUTHORITY, OR IF YOU DO NOT WISH TO ACCEPT THESE

TERMS OF USE, YOU MUST NOT ACCESS OR USE THE

HOSTED SERVICE OR AUTHORIZE ANYONE TO ACCESS OR

USE THE HOSTED SERVICE.

Licenses

THE SOFTWARE LICENSE TERMS AVAILABLE ON THE

EXTREME NETWORKS WEBSITE, 

https://extremeportal.force.com

OR SUCH SUCCESSOR SITE AS DESIGNATED BY EXTREME

NETWORKS, ARE APPLICABLE TO ANYONE WHO

DOWNLOADS, USES AND/OR INSTALLS EXTREME NETWORKS

SOFTWARE, PURCHASED FROM EXTREME NETWORKS, INC.,

ANY EXTREME NETWORKS AFFILIATE, OR AN EXTREME

NETWORKS CHANNEL PARTNER (AS APPLICABLE) UNDER A

COMMERCIAL AGREEMENT WITH EXTREME NETWORKS OR

AN EXTREME NETWORKS CHANNEL PARTNER. UNLESS

OTHERWISE AGREED TO BY EXTREME NETWORKS IN

WRITING, EXTREME NETWORKS DOES NOT EXTEND THIS

LICENSE IF THE SOFTWARE WAS OBTAINED FROM ANYONE

OTHER THAN EXTREME NETWORKS, AN EXTREME

NETWORKS AFFILIATE OR AN EXTREME NETWORKS CHANNEL

PARTNER; EXTREME NETWORKS RESERVES THE RIGHT TO

TAKE LEGAL ACTION AGAINST YOU AND ANYONE ELSE USING

OR SELLING THE SOFTWARE WITHOUT A LICENSE. BY

INSTALLING, DOWNLOADING OR USING THE SOFTWARE, OR

AUTHORIZING OTHERS TO DO SO, YOU, ON BEHALF OF

YOURSELF AND THE ENTITY FOR WHOM YOU ARE

INSTALLING, DOWNLOADING OR USING THE SOFTWARE

(HEREINAFTER REFERRED TO INTERCHANGEABLY AS “YOU”

AND “END USER”), AGREE TO THESE TERMS AND CONDITIONS

AND CREATE A BINDING CONTRACT BETWEEN YOU AND

EXTREME NETWORKS, INC. OR THE APPLICABLE EXTREME

NETWORKS AFFILIATE (“EXTREME NETWORKS”).

Extreme Networks grants You a license within the scope of the

license types described below. Where the order documentation does

not expressly identify a license type, the applicable license will be a

Designated System License as set forth below in the Designated

System(s) License (DS) section as applicable. The applicable

number of licenses and units of capacity for which the license is

granted will be one (1), unless a different number of licenses or units

of capacity is specified in the documentation or other materials

available to You. “Software” means computer programs in object

code, provided by Extreme Networks or an Extreme Networks

Channel Partner, whether as stand-alone products, pre-installed on

hardware products, and any upgrades, updates, patches, bug fixes,

or modified versions thereto. “Designated Processor” means a single

stand-alone computing device. “Server” means a set of Designated

Processors that hosts (physically or virtually) a software application

to be accessed by multiple users. “Instance” means a single copy of

the Software executing at a particular time: (i) on one physical

machine; or (ii) on one deployed software virtual machine (“VM”) or

similar deployment.

License type(s)

Designated System(s) License (DS). End User may install and use

each copy or an Instance of the Software only: 1) on a number of

Designated Processors up to the number indicated in the order; or 2)

up to the number of Instances of the Software as indicated in the

order, Documentation, or as authorized by Extreme Networks in

writing. Extreme Networks may require the Designated Processor(s)

to be identified in the order by type, serial number, feature key,

Instance, location or other specific designation, or to be provided by

End User to Extreme Networks through electronic means established

by Extreme Networks specifically for this purpose.

Copyright

Except where expressly stated otherwise, no use should be made of

materials on this site, the Documentation, Software, Hosted Service,

or hardware provided by Extreme Networks. All content on this site,

the documentation, Hosted Service, and the product provided by

Extreme Networks including the selection, arrangement and design

of the content is owned either by Extreme Networks or its licensors

and is protected by copyright and other intellectual property laws

including the sui generis rights relating to the protection of databases.

You may not modify, copy, reproduce, republish, upload, post,

transmit or distribute in any way any content, in whole or in part,

Summary of Contents for EC4400A03-E6

Page 1: ...Installing the Virtual Services Platform 4450GTX HT PWR 9035362 Rev 02 August 2018...

Page 2: ...HE TERMS OF USE IF YOU ARE ACCEPTING THE TERMS OF USE ON BEHALF A COMPANY OR OTHER LEGAL ENTITY YOU REPRESENT THAT YOU HAVE THE AUTHORITY TO BIND SUCH ENTITY TO THESE TERMS OF USE IF YOU DO NOT HAVE S...

Page 3: ...ER IS HOSTING ANY PRODUCTS THAT USE OR EMBED THE G 729 CODEC H 264 CODEC OR H 265 CODEC THE EXTREME NETWORKS CHANNEL PARTNER ACKNOWLEDGES AND AGREES THE EXTREME NETWORKS CHANNEL PARTNER IS RESPONSIBLE...

Page 4: ...cal specifications 19 Environmental requirements 19 Airflow direction 20 Package contents 20 Installing the Virtual Services Platform 4000 on a table or shelf 21 Installing the Virtual Services Platfo...

Page 5: ...ED state indicators 33 Port LED state indicators 34 Viewing hardware information 36 Chapter 6 Translations of safety messages 39 Contents August 2018 Installing the Virtual Services Platform 4450GTX H...

Page 6: ...as for improvements to our documentation so you can find the information you need faster Broken links or usability issues If you would like to provide feedback to the Extreme Networks Information Deve...

Page 7: ...on of your network environment such as layout cable type other relevant environmental information Network load at the time of trouble if known The device history for example if you have returned the d...

Page 8: ...pe your first and last name 3 Type the name of your company 4 Type your email address 5 Type your job title 6 Select the industry in which your company operates 7 Confirm your geographic information i...

Page 9: ...2 New in this document There are no feature related changes for this release in Installing the Virtual Services Platform 4450GTX HT PWR August 2018 Installing the Virtual Services Platform 4450GTX HT...

Page 10: ...e 11 Management port Extreme Networks Virtual Services Platform 4000 Series requires one port to be configured as the management port This port separates user traffic from management traffic in highly...

Page 11: ...the correct power cord for your region For more information see Power cord types and order codes on page 11 Table 2 Power supply order codes VSP 4000 PSU Usage Part number order code 1000W AC POE pow...

Page 12: ...switch as they are certified and qualified as high temperature devices However if you use a non high temperature SFP device the device is logged as an unsupported high temperature device Extreme Netw...

Page 13: ...orks does not provide support for operational issues related to these transceivers but they will operate and the port link will come up The switch logs the device as an unsupported or unknown device F...

Page 14: ...ave the following tools and cables Phillips 2 screwdriver RJ45 console port cable ESD cable See Cable requirements for the VSP 4000 on page 24 4 Unpack the equipment Observe ESD precautions when you u...

Page 15: ...escription in the area The ground path must be permanent and must not exceed 1 Ohm of resistance from the rack to the grounding electrode August 2018 Installing the Virtual Services Platform 4450GTX H...

Page 16: ...tion of AC input and DC input power supplies in the same chassis is not supported For the procedure to install power supply see Installing the VSP 4000 Series PWR power supply on page 27 3 Check the L...

Page 17: ...age Electrostatic discharge ESD is a discharge of stored static electricity that can damage equipment and impair electrical circuitry Electrostatic voltages can result from friction including pulling...

Page 18: ...able installations With new cable installations you are recommended to use an ESD discharge cable to reduce the potential for damage from static that can build up in cables The following figure illust...

Page 19: ...switches in this series Ensure that the area where you install the switch and where it operates meets these requirements Table 6 Virtual Services Platform 4000 environmental requirements Environmental...

Page 20: ...page 39 Airflow direction The airflow direction in the VSP 4450GTX HT PWR for the top half of the switch where the components exist is from left to right as viewed from the front Cool air enters the...

Page 21: ...orm 4000 on a table or shelf You can install a single VSP 4000 switch on any flat surface The surface must support the combined weight of the switch and attached cables from 15 and 20 pounds 7 to 9 ki...

Page 22: ...e used by the power service in the area The ground path must be permanent and must not exceed 1 Ohm of resistance from the rack to the grounding electrode Caution When you mount the device in a rack d...

Page 23: ...itch into the rack as illustrated 3 Insert and tighten the rack mount screws Installing the Virtual Services Platform 4000 in an equipment rack August 2018 Installing the Virtual Services Platform 445...

Page 24: ...orted in SFP ports only and not in SFP ports Console Port Varies depending on the user device The VSP 4000 has an RJ45 female connector so a serial cable with RJ45 connectors or a serial cable with a...

Page 25: ...rforming this procedure 1 Disconnect the network fiber cable from the transceiver 2 Use the locking mechanism on the transceiver to release it The locking mechanism varies from model to model as illus...

Page 26: ...ot used 2 Transmit Data TXD 3 Receive Data RXD 4 Data terminal ready not used 5 Signal ground GND 6 Not used 7 Request to send not used 8 Not used 9 Ring indicator not used Table 9 RJ45 Console port p...

Page 27: ...d in the slot Secure the power supply with the two thumb screws Note The switch chassis can prevent an incorrect installation of a power supply If you insert a power supply upside down it will not ful...

Page 28: ...Connector The 1000W AC power supply uses an IEC 60320 C16 AC power cord connector The AC power cord is in close proximity to the hot air exhaust and supports high operating temperatures Figure 4 IEC 6...

Page 29: ...r specifications are based on the maximum rated capacity of the power supplies and are not based on typical power consumption which is lower Table 13 AC power specifications 4450GTX HT PWR Input Curre...

Page 30: ...50 60 Hz Single phase United Kingdom BS1363 male plug with fuse Harmonized cord 240VAC 50 Hz Single phase Australia AS3112 1981 male plug 240VAC 50 Hz Single phase Danger Using power cords with a pro...

Page 31: ...ys perform the following shutdown procedure This procedure flushes any pending data to ensure data integrity 1 Enter the Privileged EXEC command mode enable 2 Shutdown the VSP 4000 sys shutdown 3 When...

Page 32: ...c mounts No such file or directory Deconfiguring network interfaces done Stopping syslogd klogd no syslogd found none killed Sending all processes the TERM signal Sending all processes the KILL signal...

Page 33: ...emit laser or infrared light that can injure your eyes Never look into an optical fiber or connector port Always assume that fiber optic cables are connected to a light source For a translation of th...

Page 34: ...en blinking The switch is connected to a secondary power supply but the power input is disconnected Amber solid The power supply in slot 1 or slot 2 was removed after operating Amber blinking The powe...

Page 35: ...P transceiver Port LED state indicators Label Color and Status Description In Use Green Blink Not applicable Green Steady The SFP SFP port and the transmit port are active Amber Blink Not applicable A...

Page 36: ...Name VSP 4450GTXHT PWR SysUpTime 0 day s 00 05 40 SysContact http www extremenetworks com contact SysLocation 9 Northeastern Blvd Salem NH 03079 Chassis Info Chassis 4450GTXHT PWR ModelName 4450GTXHT...

Page 37: ...s Trap false Send Authentication Trap false Error Code 0 Error Severity 0 Port Lock Info Status off LockedPorts Message Control Info Action suppress msg Control Interval 5 Max msg num 5 Status disable...

Page 38: ...Displays LED information in detail power Displays information about installed power supplies temperature Displays temperature information uboot Displays uboot details Installing the VSP 4450GTX HT PW...

Page 39: ...baie ne l empilez pas directement sur un autre Chaque module doit tre fix sa propre baie l aide des supports de montage appropri s Ces supports ne sont pas con us pour r sister plusieurs modules Impor...

Page 40: ...ns une baie veillez laisser la plaque m tallique sur la baie Si vous la retirez l a ration du module ne peut pas s effectuer correctement Important Precaution Si no instala ning n m dulo en la ranura...

Page 41: ...der facilement en cas d urgence Important Advertencia Para apagar el dispositivo debe desenchufar el cable Conecte siempre el cable de alimentaci n a una toma segura y de f cil acceso por si se produ...

Page 42: ...messa a terra Senza un adeguata messa a terra chiunque tocchi lo switch corre il rischio di ricevere una scossa elettrica L assenza di un percorso per la messa a terra verso lo switch pu comportare u...

Page 43: ...t cnico de Extreme Networks si necesita asistencia para cambiar la bater a Important Aviso A bateria de l tio n o substitu vel em campo S deve ser removida e substitu da por pessoal autorizado Entre...

Reviews: