TECHNICAL FEATURES
9
Chapter 2
TECHNICAL FEATURES
Features
Unit of
Measurement
Value
Boiler class
/
3
Introduced global heat output
kW
33.0
Max. useful heat output
kW
29.6
Min. useful heat output
kW
9.3
Yield
%
> 89
Hourly fuel consumption
kg/h
2.1 - 6.9
Flue gas temperature at max. useful heat output
°C
~ 180
Flue gas temperature at min. useful heat output
°C
~ 80
Flue gas fl ow rate at max. useful heat output
kg/s
0.018
Flue gas fl ow rate at min. useful heat output
kg/s
0.007
Chimney depression
Pa
11
Maximum hydraulic pressure
MPa
0,3
Water side head loss (17°C)
kPa
1.57 (1200 l/h)
kPa
5.54 (2500 l/h)
Water temperature adjustment
°C
65 - 80
Water return to boiler minimum temperature*
°C
55
Boiler external dimensions
mm (HxLxP)
1438 x 696 x 847
Pellet tank external dimensions
mm (HxLxP)
1351 x 618 x 720
Boiler with pellet tank external dimensions
mm (HxLxP)
1438 x 1320 x 847
Loading hatch dimensions
mm
580 x 660
Empty boiler weight
kg
415
Empty pellet tank weight
kg
100
Boiler water volume
l
65
Pellet tank capacity
l - kg
260 - 180
Smoke exhaust diameter
mm
130
Maximum electric power absorbed in the pellet ignition phase
W
800
Thermal safety valve features (water)
°C
< 20
MPa
> 0,15
The boilers are managed by a circuit board with microprocessor with a lambda probe that corrects boiler
functioning anomalies by means of constant analysis of the exhaust gases.
The data obtained from the combustion tests have been realised using the following fuels:
ONORM M7 135 DIN PLUS Pellets.
* Realise a suitable anti-condensate circuit in a way to guarantee a minimum water temperature returning
to the boiler that is equal tot he value indicated (see “SAFETY DEVICES” chapter”).