WARNINGS AND SAFETY DEVICES 

Chapter 1

The stoves produced in our establishment are built 
paying attention to the individual components in a 
way to protect the user and the installer from any 
accidents.

Installation must be carried out by authorised 
personnel who must provide the buyer with 
a system declaration of conformity certificate 
and will assume full responsibility for final 
installation and as a consequence the correct 
functioning of the installed product.
It is necessary to bear in mind all laws and 
national, regional, provincial and town council 
Standards present in the country the appliance 
has been installed.
Extraflame S.p.A. cannot be held responsible for 
the failure to comply with such precautions.

The instruction manual is an integral part of the 
product: make sure that it always accompanies 
the appliance, even if transferred to other owners 
or user or is transferred to another place. If it is 
damaged or lost, request another copy from the 
area technician.

This stove must be destined for the use for which 
it has been expressly realised. The manufacturer 
is exempt from any liability, contractual and 
extracontractual, for injury/damage caused to 
persons/animals and objects, due to installation, 
adjustment and maintenance errors and improper 
use.

After the packaging has been removed, check the 
integrity and completeness of the contents. If this 
does not comply, contact the dealer where the 
appliance was purchased.

All components that make up the stove must be 
replaced with original spare parts exclusively by 
an authorised after-sales centre, thus guaranteeing 
correct functioning.

The stove must be serviced at least once a year, 
programming it in advance with the technical after-
sales service.

For safety reasons, remember that:

The stove must not be used by children or 

 

™

unassisted disabled persons.

The safety and adjustment devices must not be 

 

™

modifi ed without the authorisation or indications 
of the manufacturer.

Do not close or reduce the dimensions of the 

 

™

airing vents in the place of installation. The airing 
vents are indispensable for correct combustion.

Do not leave the packaging elements within 

 

™

reach of children or unassisted disabled persons.

The hearth door must always be closed during 

 

™

normal functioning of the product.

Avoid direct contact with parts of the appliance 

 

™

that tend to heat up during functioning.

Check for the presence of any obstructions 

 

™

before switching the appliance on following a 
prolonged standstill period.

If the fl ue should catch fi re, be equipped with 

 

™

suitable systems for suff ocating the fl ames  or 
request help from the fi re service.

MAJOLICAS: the company has chosen 

 

™

majolica tiles, which are the result of high-quality 
artisan work and therefore the majolica may 
present crackles, speckles, and shadings. These 
characteristics certify their precious origin.Enamel 
and majolica, due to their diff erent coeffi

  cient of 

dilatation, produce microcrackles, which show 
their authentic feature.For the cleaning of the 
majolica we suggest you use a soft and dry cloth; 
if you use a detergent or liquid, the latter might 
soak in and make the crackles more visible.

WARNINGS AND SAFETY DEVICES 

Summary of Contents for Cleopatra

Page 1: ...Stufe a Pellet User manual Cleopatra Read the instructions carefully before installation use and maintenance The instruction book is an integral part of the product...

Page 2: ...2...

Page 3: ...e space in that is dedicated to your authorised specialist He will help you with pleasure if you should have problems using your new pellet stove AUTHORISED SPECIALIST COMPANY ________________________...

Page 4: ...CONNECTION TO THE FLUE AND EXHAUST OF THE COMBUSTION PRODUCTS 15 CHIMNEY CAP 15 CONNECTION TO EXTERNAL AIR INLETS 16 INSULATION FINISHINGS COVERINGS AND SAFETY RECOMMENDATIONS 16 NATIONAL REGIONAL PRO...

Page 5: ...e stove must be replaced with original spare parts exclusively by an authorised after sales centre thus guaranteeing correct functioning The stove must be serviced at least once a year programming it...

Page 6: ...to the water kW Min useful heat output kW 4 0 useful output power to the air kW 4 0 useful output power to the water kW Min hourly fuel consumption kg h 1 0 Max hourly fuel consumption kg h 2 0 Feed...

Page 7: ...7 TECHNICAL FEATURES Chapter 2 figure 2 1...

Page 8: ...s a calorific value of 4 4 kW kg with 15 humidity therefore after about 18 months seasoning that of the pellet is 5 3 kW kg Pellet density is about 650 kg m3 and water content is equal to 8 of its wei...

Page 9: ...owto 1 feed the pellets and check the correct positioning of lever A Open the handle of the tank lid 2 On opening the tank lid there is a compartment 3 with a capacity equal to about 5 kg where the pe...

Page 10: ...the stove it is impossible to open the tank lid Once the pellet has descended take the knob A to its original position position 2 6 To fill the tank to maximum capacity just repeat the points from nu...

Page 11: ...geological formation and transformed in fossil BIOFUEL Fuel produced directly or indirectly by biomass CHIMNEY Vertical pipe with the aim to collect and expel at a convenient height from the ground t...

Page 12: ...rminals positioning of appliances similarly to No installation Legal distances Limitations disposed by local administrative regulations or particular authority prescriptions Conventional limitations d...

Page 13: ...condensate and avoid it being transported towards the appliance The mounting of horizontal routes must be avoided For appliances where ceiling or wall non coaxial discharges respect to the appliance s...

Page 14: ...mmable objects Non inflammable objects A 200 100 B 1500 750 C 200 100 the appliance must be installed on a floor that has suitable load capacity If the existing construction does not satisfy this requ...

Page 15: ...outlet section not lower than double the chimney internal section be built in order to avoid rain snow foreign bodies penetrating the chimney and in order that in case of winds in any direction and in...

Page 16: ...xternal environment by means of reverse draught caused by the presence of another used appliance or intake deviceinsuchroom Thepermanentopeningsintheadjacentroommustcomplywiththeabove described requis...

Page 17: ...The hardening of the surfaces is terminated after several heating processes This appliance must not be used to burn waste AIR REGISTER The Cleopatra stove has a register for the regulation of primary...

Page 18: ...the feed box is always half full 3 SWITCH OFF Cleopatra is supplied with a system that interrupts pellet supply to the burner using a lever it is possible to block the natural sliding of the pellet to...

Page 19: ...ever to prevent burns and move forward backwards and vice versa Repeat the operation 2 3 times a day ASH DRAWER The ash drawer must be emptied on necessity Open the lower door for access CLEANING THE...

Page 20: ...to prevent explosion Do not use cloths abrasive or chemically aggressive products GASKETS The gaskets guarantee the tightness of the stove and its consequent good functioning These must be checked re...

Page 21: ...r inspection lid positioned incorrectly Check sealing of the upper lid gaskets of the intermediate base of the tank the lateral inspection lid and the upper inspection lid If they are worn contact qua...

Page 22: ...transversal section of the flue is excessive Butterfly valve in the closed flue Flue draught too low Burner dirty and blocked Gaskets used Upper inspection lid positioned incorrectly Al piping must be...

Page 23: ...After sales Service or the dealer Thewarrantdocument filled inandaccompaniedbythereceipt mustbekeptandshowntostaffofthe 3 Extraflame S p A Technical After sales Service in the case of intervention Th...

Page 24: ...ea After Sales Centre For products sold abroad the same situations will always be free of charge ex our establishment with the exception of particular conditions agreed during negotiations with the fo...

Page 25: ...ed by the company with full respect of the Legislative Decree 196 2003 for the entire duration of the contractual relationship and subsequently in order to fulfil all legal requirements as well as to...

Page 26: ...26 Notes...

Page 27: ...27 Notes...

Page 28: ...003 0810008 EXTRAFLAME S p A Via Dell Artigianato 10 36030 MONTECCHIO PRECALCINO Vicenza ITALY Tel 0445 865911 Fax 0445 865912 http www lanordica extraflame com E mail info extraflame com This documen...

Reviews: