background image

23

WARRANTY

Chapter 8

WARRANTY

EXTRAFLAME  S.p.A.  You are reminded that the manufacturer is the owner of the rights envisioned 
by the Legislative Decree dated 2 February 2002, n. 24 and the following warranty does jeopardise 
these rights.

This warranty certifi cate, granted by Extrafl ame S.p.A., with offi

  ces in Montecchio Precalcino (VI), via 

dell’Artigianato 10, refers to all stove components supplied by Extrafl ame S.p.A. and is extended to the free 
repair or replacement of any part of the defective appliance, on the condition that:

the same defect is detected within 2 YEARS from the product delivery date and is communicated to 

 

™

an Extrafl ame S.p.A. After-Sales Centre within 2 months from its discovery;

is recognised as such by an Extrafl ame S.p.A. After-Sales Centre.

 

™

No cost or expense will be charged to the client for interventions that the Extrafl ame S.p.A. After-Sales 
Centre will carry out if provided by the warranty certifi cate.

WARRANTY CONDITIONS

The warranty is considered valid on the condition that:

The stove is installed in compliance with the Standards in force on this subject, the prescriptions contained 

1. 
in this manual and professionally qualifi ed staff .

The customer has fi lled-in and signed the warranty certifi cate, validated by the Extrafl ame S.p.A.  Technical 

2. 
After-sales Service or the dealer.

The warrant document, fi lled-in and accompanied by the receipt, must be kept and shown to staff  of the 

3. 
Extrafl ame S.p.A.  Technical After-sales Service in the case of intervention.

The warranty is not considered valid in the following cases:

The warranty conditions described above have not been respected.

1. 

Installation has not been performed with respect to the Standards in force regarding the provisions 

2. 
described in this manual.

Negligence of the customer due to lack of or incorrect maintenance of the product.

3. 

Damages deriving from atmospheric agents, chemicals, electro-chemicals, improper use of the product, 

4. 
modifi cations or tampering of the product, ineffi

  cacy and/or unsuitability of the fl ue and/or other causes 

not deriving from the manufacture of the product.

Damage caused by normal corrosion or deposits typical of the central heating systems (condition valid 

5. 
for water products).

Improper or negligent use of the stove.

6. 

All damage caused by transport. It is therefore recommended to carefully check the goods on receipt, 

7. 
informing the dealer of any damage immediately, making a note on the transport document and on the 
carrier’s copy.

Extrafl ame S.p.A. is not liable for any damage/injury that can, directly or indirectly, aff ect persons, objects 
and pets as a consequence of failure to comply with the prescriptions indicated in this manual and the 
standards in force regarding installation and maintenance of the appliance.

Summary of Contents for Cleopatra

Page 1: ...Stufe a Pellet User manual Cleopatra Read the instructions carefully before installation use and maintenance The instruction book is an integral part of the product...

Page 2: ...2...

Page 3: ...e space in that is dedicated to your authorised specialist He will help you with pleasure if you should have problems using your new pellet stove AUTHORISED SPECIALIST COMPANY ________________________...

Page 4: ...CONNECTION TO THE FLUE AND EXHAUST OF THE COMBUSTION PRODUCTS 15 CHIMNEY CAP 15 CONNECTION TO EXTERNAL AIR INLETS 16 INSULATION FINISHINGS COVERINGS AND SAFETY RECOMMENDATIONS 16 NATIONAL REGIONAL PRO...

Page 5: ...e stove must be replaced with original spare parts exclusively by an authorised after sales centre thus guaranteeing correct functioning The stove must be serviced at least once a year programming it...

Page 6: ...to the water kW Min useful heat output kW 4 0 useful output power to the air kW 4 0 useful output power to the water kW Min hourly fuel consumption kg h 1 0 Max hourly fuel consumption kg h 2 0 Feed...

Page 7: ...7 TECHNICAL FEATURES Chapter 2 figure 2 1...

Page 8: ...s a calorific value of 4 4 kW kg with 15 humidity therefore after about 18 months seasoning that of the pellet is 5 3 kW kg Pellet density is about 650 kg m3 and water content is equal to 8 of its wei...

Page 9: ...owto 1 feed the pellets and check the correct positioning of lever A Open the handle of the tank lid 2 On opening the tank lid there is a compartment 3 with a capacity equal to about 5 kg where the pe...

Page 10: ...the stove it is impossible to open the tank lid Once the pellet has descended take the knob A to its original position position 2 6 To fill the tank to maximum capacity just repeat the points from nu...

Page 11: ...geological formation and transformed in fossil BIOFUEL Fuel produced directly or indirectly by biomass CHIMNEY Vertical pipe with the aim to collect and expel at a convenient height from the ground t...

Page 12: ...rminals positioning of appliances similarly to No installation Legal distances Limitations disposed by local administrative regulations or particular authority prescriptions Conventional limitations d...

Page 13: ...condensate and avoid it being transported towards the appliance The mounting of horizontal routes must be avoided For appliances where ceiling or wall non coaxial discharges respect to the appliance s...

Page 14: ...mmable objects Non inflammable objects A 200 100 B 1500 750 C 200 100 the appliance must be installed on a floor that has suitable load capacity If the existing construction does not satisfy this requ...

Page 15: ...outlet section not lower than double the chimney internal section be built in order to avoid rain snow foreign bodies penetrating the chimney and in order that in case of winds in any direction and in...

Page 16: ...xternal environment by means of reverse draught caused by the presence of another used appliance or intake deviceinsuchroom Thepermanentopeningsintheadjacentroommustcomplywiththeabove described requis...

Page 17: ...The hardening of the surfaces is terminated after several heating processes This appliance must not be used to burn waste AIR REGISTER The Cleopatra stove has a register for the regulation of primary...

Page 18: ...the feed box is always half full 3 SWITCH OFF Cleopatra is supplied with a system that interrupts pellet supply to the burner using a lever it is possible to block the natural sliding of the pellet to...

Page 19: ...ever to prevent burns and move forward backwards and vice versa Repeat the operation 2 3 times a day ASH DRAWER The ash drawer must be emptied on necessity Open the lower door for access CLEANING THE...

Page 20: ...to prevent explosion Do not use cloths abrasive or chemically aggressive products GASKETS The gaskets guarantee the tightness of the stove and its consequent good functioning These must be checked re...

Page 21: ...r inspection lid positioned incorrectly Check sealing of the upper lid gaskets of the intermediate base of the tank the lateral inspection lid and the upper inspection lid If they are worn contact qua...

Page 22: ...transversal section of the flue is excessive Butterfly valve in the closed flue Flue draught too low Burner dirty and blocked Gaskets used Upper inspection lid positioned incorrectly Al piping must be...

Page 23: ...After sales Service or the dealer Thewarrantdocument filled inandaccompaniedbythereceipt mustbekeptandshowntostaffofthe 3 Extraflame S p A Technical After sales Service in the case of intervention Th...

Page 24: ...ea After Sales Centre For products sold abroad the same situations will always be free of charge ex our establishment with the exception of particular conditions agreed during negotiations with the fo...

Page 25: ...ed by the company with full respect of the Legislative Decree 196 2003 for the entire duration of the contractual relationship and subsequently in order to fulfil all legal requirements as well as to...

Page 26: ...26 Notes...

Page 27: ...27 Notes...

Page 28: ...003 0810008 EXTRAFLAME S p A Via Dell Artigianato 10 36030 MONTECCHIO PRECALCINO Vicenza ITALY Tel 0445 865911 Fax 0445 865912 http www lanordica extraflame com E mail info extraflame com This documen...

Reviews: