Chapter 4
ASSEMBLY AND INSTALLATION INSTRUCTIONS
CHIMNEY OR INDIVIDUAL FLUE
The chimney or individual fl ue must respond to the following requisites:
sealed from combustion products, impermeable and suitably isolated and insulated; to the similar
conditions of use;
be realised with materials which resist the normal mechanical stresses, heat, action of the fuel products
and any condensing;
have mainly vertical progress with deviations from the axis not higher than 45°;
be adequately distanced from fuel or fl ammable materials through air space or opportune
insulation;
Minimum 80 cm
2
Floor-protection
REFERENCES
Infl ammable
objects
Non-infl ammable
objects
A
200
100
B
1500
750
C
200
100
the appliance must be installed on a fl oor that has suitable load capacity. If the existing construction
does not satisfy this requisite, use the appropriate measures (e.g. load distribution plate). The appliance
must be positioned perfectly horizontally.
have preferably circular internal section: the square or rectangular sections must have round corners
with a radius not lower than 20 mm.
have constant internal section, free and independent.
have rectangular section with max. ratio between the sides of 1.5.
It is recommended that the smoke pipe be equipped with a collection chamber for solid materials and any
condensing situated under the smoke channel inlet, so that it can be easily opened and inspected from
airtight door.