RECOMMENDATIONS FOR USE

The fi re burns well but 
the stove and the room 
do not heat up

Excessive fl ue draught

 

™

Room of installation too big or with 

 

™

dispersion points of excessive heat.

Regulate draught to between 14 and 20 Pa using 

 

™

the butterfl y in the fl ue

Insulate the room as well as possible in order to 

 

™

limit heat dispersion

The pellet burns too 
quickly

Excessive fl ue draught

 

™

Excessive inlet primary air

 

™

Regulate draught to between 14 and 20 Pa using 

 

™

the butterfl y in the fl ue

Reduce the inlet primary air using the regulation 

 

™

knob

Smoke escaping in the 
room during normal 
functioning

Butterfl y valve in the closed fl ue

 

™

Flue gas exhaust pipe blocked by 

 

™

soot

Flue draught too low

 

™

Burner dirty and blocked

 

™

Gaskets used

 

™

Upper inspection lid positioned 

 

™

incorrectly

Check that the fl ue is not obstructed by soot, that 

 

™

the butterfl y for draught regulation is not completely 
closed and that draught between 14 and 20 Pa is 
guaranteed

Increase the inlet primary air using the regulation 

 

™

knob

Use the grate shaker combs to clean the burner

 

™

Check the correct position of the upper inspection 

 

™

lid

Check sealing of the upper lid gaskets, of the 

 

™

intermediate base of the tank, the lateral inspection 
lid and the upper inspection lid. If they are worn, 
contact qualifi ed staff  for their replacement

The fl ue becomes 
wet and covered with 
soot with condensate 
escaping from the 
pipes

The fl ue is too cold

 

™

The transversal section of the fl ue is 

 

™

excessive

Butterfl y valve in the closed fl ue

 

™

Flue draught too low

 

™

Burner dirty and blocked

 

™

Gaskets used

 

™

Upper inspection lid positioned 

 

™

incorrectly

Al piping must be isolated

 

™

Reduce fl ue section

 

™

Check that the fl ue is not obstructed by soot, that 

 

™

the butterfl y for draught regulation is not completely 
closed and that draught between 14 and 20 Pa is 
guaranteed

Use the grate shaker combs to clean the burner

 

™

Check the correct position of the upper inspection 

 

™

lid

Check sealing of the upper lid gaskets, of the 

 

™

intermediate base of the tank, the lateral inspection 
lid and the upper inspection lid. If they are worn, 
contact qualifi ed staff  for their replacement

The fl ame only burns 
slightly even if the 
primary air valve is 
open

Butterfl y valve in the closed fl ue

 

™

Flue gas exhaust pipe blocked by 

 

™

soot

Flue draught too low

 

™

Insuffi

  cient primary air inlet

 

™

Burner dirty and blocked

 

™

Gaskets used

 

™

Upper inspection lid positioned 

 

™

incorrectly

The pellets do not slide into the 

 

™

tank

Check that the fl ue is not obstructed by soot, that 

 

™

the butterfl y for draught regulation is not completely 
closed and that draught between 14 and 20 Pa is 
guaranteed.

Increase the inlet primary air using the regulation 

 

™

knob

Use the grate shaker combs to clean the burner

 

™

Check the correct position of the upper inspection 

 

™

lid

Check sealing of the upper lid gaskets, of the 

 

™

intermediate base of the tank, the lateral inspection 
lid and the upper inspection lid. If they are worn, 
contact qualifi ed staff  for their replacement 

Check the opening of the lever that blocks sliding 

 

™

of the pallet into the tank

Summary of Contents for Cleopatra

Page 1: ...Stufe a Pellet User manual Cleopatra Read the instructions carefully before installation use and maintenance The instruction book is an integral part of the product...

Page 2: ...2...

Page 3: ...e space in that is dedicated to your authorised specialist He will help you with pleasure if you should have problems using your new pellet stove AUTHORISED SPECIALIST COMPANY ________________________...

Page 4: ...CONNECTION TO THE FLUE AND EXHAUST OF THE COMBUSTION PRODUCTS 15 CHIMNEY CAP 15 CONNECTION TO EXTERNAL AIR INLETS 16 INSULATION FINISHINGS COVERINGS AND SAFETY RECOMMENDATIONS 16 NATIONAL REGIONAL PRO...

Page 5: ...e stove must be replaced with original spare parts exclusively by an authorised after sales centre thus guaranteeing correct functioning The stove must be serviced at least once a year programming it...

Page 6: ...to the water kW Min useful heat output kW 4 0 useful output power to the air kW 4 0 useful output power to the water kW Min hourly fuel consumption kg h 1 0 Max hourly fuel consumption kg h 2 0 Feed...

Page 7: ...7 TECHNICAL FEATURES Chapter 2 figure 2 1...

Page 8: ...s a calorific value of 4 4 kW kg with 15 humidity therefore after about 18 months seasoning that of the pellet is 5 3 kW kg Pellet density is about 650 kg m3 and water content is equal to 8 of its wei...

Page 9: ...owto 1 feed the pellets and check the correct positioning of lever A Open the handle of the tank lid 2 On opening the tank lid there is a compartment 3 with a capacity equal to about 5 kg where the pe...

Page 10: ...the stove it is impossible to open the tank lid Once the pellet has descended take the knob A to its original position position 2 6 To fill the tank to maximum capacity just repeat the points from nu...

Page 11: ...geological formation and transformed in fossil BIOFUEL Fuel produced directly or indirectly by biomass CHIMNEY Vertical pipe with the aim to collect and expel at a convenient height from the ground t...

Page 12: ...rminals positioning of appliances similarly to No installation Legal distances Limitations disposed by local administrative regulations or particular authority prescriptions Conventional limitations d...

Page 13: ...condensate and avoid it being transported towards the appliance The mounting of horizontal routes must be avoided For appliances where ceiling or wall non coaxial discharges respect to the appliance s...

Page 14: ...mmable objects Non inflammable objects A 200 100 B 1500 750 C 200 100 the appliance must be installed on a floor that has suitable load capacity If the existing construction does not satisfy this requ...

Page 15: ...outlet section not lower than double the chimney internal section be built in order to avoid rain snow foreign bodies penetrating the chimney and in order that in case of winds in any direction and in...

Page 16: ...xternal environment by means of reverse draught caused by the presence of another used appliance or intake deviceinsuchroom Thepermanentopeningsintheadjacentroommustcomplywiththeabove described requis...

Page 17: ...The hardening of the surfaces is terminated after several heating processes This appliance must not be used to burn waste AIR REGISTER The Cleopatra stove has a register for the regulation of primary...

Page 18: ...the feed box is always half full 3 SWITCH OFF Cleopatra is supplied with a system that interrupts pellet supply to the burner using a lever it is possible to block the natural sliding of the pellet to...

Page 19: ...ever to prevent burns and move forward backwards and vice versa Repeat the operation 2 3 times a day ASH DRAWER The ash drawer must be emptied on necessity Open the lower door for access CLEANING THE...

Page 20: ...to prevent explosion Do not use cloths abrasive or chemically aggressive products GASKETS The gaskets guarantee the tightness of the stove and its consequent good functioning These must be checked re...

Page 21: ...r inspection lid positioned incorrectly Check sealing of the upper lid gaskets of the intermediate base of the tank the lateral inspection lid and the upper inspection lid If they are worn contact qua...

Page 22: ...transversal section of the flue is excessive Butterfly valve in the closed flue Flue draught too low Burner dirty and blocked Gaskets used Upper inspection lid positioned incorrectly Al piping must be...

Page 23: ...After sales Service or the dealer Thewarrantdocument filled inandaccompaniedbythereceipt mustbekeptandshowntostaffofthe 3 Extraflame S p A Technical After sales Service in the case of intervention Th...

Page 24: ...ea After Sales Centre For products sold abroad the same situations will always be free of charge ex our establishment with the exception of particular conditions agreed during negotiations with the fo...

Page 25: ...ed by the company with full respect of the Legislative Decree 196 2003 for the entire duration of the contractual relationship and subsequently in order to fulfil all legal requirements as well as to...

Page 26: ...26 Notes...

Page 27: ...27 Notes...

Page 28: ...003 0810008 EXTRAFLAME S p A Via Dell Artigianato 10 36030 MONTECCHIO PRECALCINO Vicenza ITALY Tel 0445 865911 Fax 0445 865912 http www lanordica extraflame com E mail info extraflame com This documen...

Reviews: