22
Chapter 7
RECOMMENDATIONS FOR USE
The fi re burns well but
the stove and the room
do not heat up
Excessive fl ue draught
Room of installation too big or with
dispersion points of excessive heat.
Regulate draught to between 14 and 20 Pa using
the butterfl y in the fl ue
Insulate the room as well as possible in order to
limit heat dispersion
The pellet burns too
quickly
Excessive fl ue draught
Excessive inlet primary air
Regulate draught to between 14 and 20 Pa using
the butterfl y in the fl ue
Reduce the inlet primary air using the regulation
knob
Smoke escaping in the
room during normal
functioning
Butterfl y valve in the closed fl ue
Flue gas exhaust pipe blocked by
soot
Flue draught too low
Burner dirty and blocked
Gaskets used
Upper inspection lid positioned
incorrectly
Check that the fl ue is not obstructed by soot, that
the butterfl y for draught regulation is not completely
closed and that draught between 14 and 20 Pa is
guaranteed
Increase the inlet primary air using the regulation
knob
Use the grate shaker combs to clean the burner
Check the correct position of the upper inspection
lid
Check sealing of the upper lid gaskets, of the
intermediate base of the tank, the lateral inspection
lid and the upper inspection lid. If they are worn,
contact qualifi ed staff for their replacement
The fl ue becomes
wet and covered with
soot with condensate
escaping from the
pipes
The fl ue is too cold
The transversal section of the fl ue is
excessive
Butterfl y valve in the closed fl ue
Flue draught too low
Burner dirty and blocked
Gaskets used
Upper inspection lid positioned
incorrectly
Al piping must be isolated
Reduce fl ue section
Check that the fl ue is not obstructed by soot, that
the butterfl y for draught regulation is not completely
closed and that draught between 14 and 20 Pa is
guaranteed
Use the grate shaker combs to clean the burner
Check the correct position of the upper inspection
lid
Check sealing of the upper lid gaskets, of the
intermediate base of the tank, the lateral inspection
lid and the upper inspection lid. If they are worn,
contact qualifi ed staff for their replacement
The fl ame only burns
slightly even if the
primary air valve is
open
Butterfl y valve in the closed fl ue
Flue gas exhaust pipe blocked by
soot
Flue draught too low
Insuffi
cient primary air inlet
Burner dirty and blocked
Gaskets used
Upper inspection lid positioned
incorrectly
The pellets do not slide into the
tank
Check that the fl ue is not obstructed by soot, that
the butterfl y for draught regulation is not completely
closed and that draught between 14 and 20 Pa is
guaranteed.
Increase the inlet primary air using the regulation
knob
Use the grate shaker combs to clean the burner
Check the correct position of the upper inspection
lid
Check sealing of the upper lid gaskets, of the
intermediate base of the tank, the lateral inspection
lid and the upper inspection lid. If they are worn,
contact qualifi ed staff for their replacement
Check the opening of the lever that blocks sliding
of the pallet into the tank