Section 924
ASPEN EFD1000 PILOT PFD
924 - 12
Page Date: 31. March 2009
Pilot´s Operating Handbook
EXTRA 300L
MENU OPTIONS
General Settings Page
From the GENERAL SETTINGS page the pilot may:
· Configure the barometric altimeter setting units to inches or millibars (in/mB)
· ENABLE or DISABLE the display of V-Speeds
· Perform an AHRS RESET.
V-Speed Setting Pages
This page is configured by EXTRA according to the speed values given in Section 4.0.1 of this
Handbook. Values can be changed by the pilot.
Power Settings Page
The POWER SETTINGS page is used to monitor and control the source of power to the EFD1000
PILOT PFD, including overriding automatic power states. From the POWER SETTINGS Page the
pilot may:
· Switch to Battery Power from External Power
· Switch to External Power from Battery Power
· Shut down or Re-Start the unit
· View the External Power Source Voltage
· View the Internal Battery Status
924.8
HANDLING, SERVICING AND MAINTENANCE
If the temperature sensor of the RSM is suspected to fail, it is advisable to initiate a check of the
RSM vent hole. Consider that it is necessary to remove the aircraft tail fairing for that purpose.
Replace the internal battery every 3 years or 2200 hours.
Check unit and wiring each 100 hours or during annual inspection.
Refer to Aspen Document #A-01-126-00 latest revision for Instructions for Continued Airworthiness.