Section 909
Smoke System
909 - 4
Page Date: 20. April 2002
Pilot´s Operating Handbook
EXTRA 300L
909.3
EMERGENCY PROCEDURES
FAILURE OF THE SMOKE-SYSTEM
1. Switch "SMOKE ARM" and "SMOKE REFILL": OFF
2. Circuit breaker
PULL
FIRE IN FLIGHT
1. Switch "SMOKE ARM"
OFF
If the fire (after the smoke system is shut off) will not extinguish proceed as follows:
2. Mixture
IDLE CUT OFF
3. Fuel selector valve
OFF (Pull & Turn)
4. Master switch
OFF
5. Airspeed
100 KIAS (185 km/h)
find your airspeed/attitude that
will keep the fire away from the cockpit
6. Land
AS SOON AS POSSIBLE
7. If fire persists or aircraft is uncontrollable
and wearing a parachute
BAIL OUT
SMOKE IN THE COCKPIT
1. Switch "SMOKE ARM"
OFF
2. Bad weather window
OPEN
3. Ventilation
OPEN
4. If smoke persists in the cockpit, land
AS SOON AS PRACTICAL
909.4
NORMAL PROCEDURES
The smoke system includes features for refilling the smoke tanks and smoke generation:
A) REFILL
A separate refill hose is delivered with the smoke system which has to be used for filling the
smoke oil tanks from the paraffin oil supply cansister or barrel.
1. Refill hose
CONNECT hose nipple to quick
connector at the fuselage bottom;
IMMERSE the other end into the paraffin
oil in the canister/barrel
2. Switch "SMOKE REFILL"
ON
N O T E
The refilling should start within max. 30 sec. If this is not the case, the refill lines,
fittings and filter (if installed) have to be checked for soiling or leaks. Refilling
procedure can be supported by reducing the suction height e.g. lifting the canister.
The fully filled status is sensed by the floating device which automatically switches
the refilling off.
Page Date: 20. January 2016
Summary of Contents for 300L