background image

DT200-EU-EN-V2.0   4/12 

2

Introduction 

Congratulations on your purchase of the Extech Model DT200 Laser Distance Meter. This meter 
measures Distance up to 35m (115’) and calculates Area and Volume. In addition, the DT200 
includes a laser pointer for accurate targeting. This meter is shipped fully tested and calibrated 
and, with proper use, will provide years of reliable service. 

Safety Instructions 

This meter has been designed for safe use, but must be operated with caution.  

 

WARNING: Do not directly view or direct the laser pointer at an eye. 

Low power visible lasers 

do not normally present a hazard, but may present some potential for hazard if viewed directly 
for extended periods of time. 

 
Laser classification (Class 2) 

The DT200 produces a visible Class 2 laser beam from the top of 
the instrument. Do not stare into the laser beam or direct the beam 
toward anyone’s eyes. Eye protection is normally an automatic 
response (‘blink reflex’, for example). 

 
Warning: 

Do not look directly into the laser beam using optical 

aids such as binoculars or telescopes. This can create a hazard. 
 

 

Permitted Uses 

 

 Measure 

Distances 

 

Compute Area and Volume 

 Measure 

Angles 

 

Prohibited Uses 

 

Exceeding the specified measurement limits 

 

Compromising or deactivating the safety systems built into the meter 

 

Removal of hazard or explanatory labels affixed to the meter 

 

Modifying or converting the instrument 

 

Using third party accessories 

 

Operation on scaffolding or ladders without proper safety precautions 

 

Measuring near machines that are operating or near parts of machine installations that are 
unprotected 

 

Aiming the meter into the sunlight 

 

Outdoor measurements or measurements on roads, near construction sites, etc. without 
adequate safeguards 

Summary of Contents for DT200

Page 1: ...User Guide Laser Distance Meter Extech DT200 DT200 ...

Page 2: ...er beam from the top of the instrument Do not stare into the laser beam or direct the beam toward anyone s eyes Eye protection is normally an automatic response blink reflex for example Warning Do not look directly into the laser beam using optical aids such as binoculars or telescopes This can create a hazard Permitted Uses Measure Distances Compute Area and Volume Measure Angles Prohibited Uses ...

Page 3: ...e and Indirect Measurement icons 5 Single Distance Measurement mode 6 Battery status icon 7 Reading Memory Location Number 8 Error icon 9 Continuous MIN MAX measurement mode 10 Display Line 1 11 Display Line 2 12 Display Line 3 Summary Display Line Keypad Power ON Measurement Button CLEAR Power OFF Button Measurement Reference Button Backlight Unit Button MAX MIN Continuous Measurement Button Indi...

Page 4: ... ON The unit automatically switches OFF after three 3 minutes of inactivity 2 Press and hold the UNIT button to change the unit of measure ft feet in inches m meters and feet and inches 3 Use the reference button to select the Top or Bottom distance reference In the Top mode 2 the displayed reading will represent the distance from the top of the meter to the target In the Bottom mode 1 the display...

Page 5: ... Press the MEAS button to take the first measurement 3 Press the button or the button or will appear in the display flashing 4 Press the MEAS button again to take another measurement 5 The two individual measurements will be shown on display lines 1 and 2 6 The sum or difference will be indicated on display line 3 7 Repeat the above steps as desired Area Calculation The DT200 allows the user to co...

Page 6: ...nt 11 Lines 1 2 and 3 will now show the Length Width and Area in ft 3 or m 3 respectively Note that the individual Height measurement is NOT displayed Indirect Measurements Using Two Measurements The DT200 can measure the vertical height from Point 1 to Point 2 with the operator taking the measurement from Point X This is accomplished using two measurements 1 Press the MEAS button to switch the me...

Page 7: ...ttom diagonal line flashing 4 From Point X aim the instrument at Point 1 and press MEAS One reading is now complete and the middle line of the triangle will begin flashing 5 Press MEAS again to turn on the laser pointer to prepare for the next measurement 6 From Point X aim the instrument horizontally at a Point 2 and press MEAS The second reading is now complete and the top diagonal line of the t...

Page 8: ...ed in location 1 and the previous reading from location 1 will be moved to location 2 5 When all twenty locations have been filled the meter begins overwriting the existing readings 6 The memory location number is indicated on the upper left hand area of the display 1 to 20 7 Use the and bottons to scroll through the the stored readings 8 To clear all readings enter the memory mode using the Memor...

Page 9: ... the low battery symbol appears on the display or when the display does not switch ON replace the two 2 AAA batteries 1 Switch the instrument off before replacing the batteries 2 Remove the rear battery compartment cover by sliding the grooved latch on the meter bottom toward the rear of the meter 3 Replace the two 2 AAA batteries observing polarity 4 Replace the battery compartment cover 5 You as...

Page 10: ...4 5 x 1 9 x 1 1 115 x 48 x 28mm Weight 5 3 oz 150g Recommended use For indoor use only Range Specifications Distance Range 0 1 to 35m 4 to 115 Resolution 0 001 inches feet or meters Accuracy 2mm 0 08 Displayed Calculation Ranges Length 99 11 99 99m Area 999 99 sq ft 999 99m2 Volume 999 99 cu ft 999 99m3 Copyright 2012 Extech Instruments Corporation a FLIR company All rights reserved including the ...