CO80 V3.1 04/06
34
As soon as the test has commenced, a log number will automatically be
generated. The sequence follows on from the last report number. Once
more than 25 reports are stored, the next CO report overwrites the oldest
stored report.
The display alternates between the following two screens every second:
5.5.2 CO Room Test Mode (Cont.)
After 15 minutes, a “beeper” sounds for one minute – if the readings are
stable (i.e. fallen to zero) up to this point, it
may
be allowable to stop the
CO room test for that appliance at this moment (refer to legislation and/or
appliance manufactures instructions).
After 30 minutes, the CO80 emits a sound that indicates the required
timing period has finished and the maximum CO value in ppm is recorded
and displayed.
Note: Pressing and holding “
Log
” anytime during the test will start a new
report.
Warning
The previous readings will not be stored to memory until it has been
printed.
To print press “
Scroll
” until the
“Print”
flashes. Press and hold “
Log
”
until a beep is heard – the last activated report will print. This report is now
Denotes CO Room test
is in progress.
Indicates how many one-
minute readings have
taken place (in this case
twelve).
Indicates that the maximum
CO readings are in progress.
Value of CO in parts per
million (ppm).