20
2.9 $AA8V (for EX9016D only)
Description:
Set LED Configuration
Syntax:
$AA8V[CHK](cr)
$ delimiter character
AA address of reading/response module(00 to FF)
8 command for read LED configuration
V 1=Set LED to module, 2=Set LED to host
Response:
Valid Command:
!AA
Invalid Command:
?AA
Example:
Command: $ 0182 Receive: !011
Set address 01 LED to host control, return success.
Command: $ 0181 Receive: !010
Set address 01 LED to module control, return success.