21
2.10 $AA9(Data) (for EX9016D only)
Description:
Set LED Configuration
Syntax:
$AA9(data)[CHK](cr)
$ delimiter character
AA address of reading/response module(00 to FF)
9 command for setting LED data
(Data) data display on the LED, range from -19999. to +19999.
The data need sign, 5 digits and decimal point.
Response:
Valid Command:
!AA
Invalid Command:
?AA
Example:
Command: $ 019+123.45 Receive: !011
Set address 01 LED data to +123.45, return success.