28
A socket port is assigned for the serial port. It’s a 16-bit numbers,
ranging from 1 to 65535. Because the numbers below 1000 are used for
specific purposes (e.g. 80 is for HTTP protocol), we suggest you use
the numbers larger than
1000
. Generally the port number 4660 is used
for the serial communication. However you should specify different
port number for each serial port.
□
□
□
Socket type
TCP Server: TCP protocol, passive open, to be connected from the
TCP client
s
.
TCP Client: TCP protocol, active open, connects to the TCP server.
UDP Client: UDP protocol, connectionless
□
□
□
Remote IP address
The server IP address and socket port would be connected in TCP
Client and UDP Client mode for a certain serial port.
□
□
□
Remote socket port
The server socket port would be connected in TCP Server, TCP Client
and UDP Client mode for a certain serial port.
□
□
□
Interface of serial I/O
It provides an
“Auto Detect”
function and just depends on the
connected serial device’s interface as RS-422 or RS-485.
□
□
□
Baudrate
Baud Rate: 300 ~ 115200 bps
□
□
□
Parity, Data bits, Stop bit
Parity: None, Even, Odd, Space, Mark.
Data Bits: 5, 6, 7, 8.
Stop Bit: 1 or 2.
□
□
□
Force off-line time
It is for setting the off-line time period of device will be taken when
there is no date input. The parameter can be from
“0 to 99”
and the
time unit is
“Minute”
.
□
□
□
Packet Collect Time
It is for setting a packet collecting period of the device serial port’s Tx
and Rx. The parameter can be from
“0 to 999”
and the time unit is
“mSec”
.